A Novel Proton Pencil Beam Scanning FLASH RT Delivery Method Enables Optimal OAR Sparing and Ultra-High Dose Rate Delivery: A Comprehensive Dosimetry Study for Lung Tumors

SIMPLE SUMMARY: This study attempts to answer a novel and clinically relevant question of the value of Bragg-peak-based FLASH planning for lung tumors. Most existing studies and literature are limited to using transmission proton beams at ultra-high dose rates, resulting in unnecessary irradiation e...

Descripción completa

Detalles Bibliográficos
Autores principales: Wei, Shouyi, Lin, Haibo, Choi, J. Isabelle, Simone, Charles B., Kang, Minglei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8616118/
https://www.ncbi.nlm.nih.gov/pubmed/34830946
http://dx.doi.org/10.3390/cancers13225790
_version_ 1784604270665924608
author Wei, Shouyi
Lin, Haibo
Choi, J. Isabelle
Simone, Charles B.
Kang, Minglei
author_facet Wei, Shouyi
Lin, Haibo
Choi, J. Isabelle
Simone, Charles B.
Kang, Minglei
author_sort Wei, Shouyi
collection PubMed
description SIMPLE SUMMARY: This study attempts to answer a novel and clinically relevant question of the value of Bragg-peak-based FLASH planning for lung tumors. Most existing studies and literature are limited to using transmission proton beams at ultra-high dose rates, resulting in unnecessary irradiation exposure to normal tissues beyond the target volume. By combining a new hardware design (universal range shifter and range compensator) and an inverse planning system, the novel Bragg peak method makes the Bragg-peak-based FLASH planning possible. The treatment planning study and dosimetry comparison between single-energy proton Bragg peak beams and transmission proton beams demonstrated superior performances in OAR sparing and comparable FLASH dose rate of the Bragg peak FLASH. Beam angle optimization can further improve Bragg peak FLASH dosimetry performance while maintaining the similar 3D FLASH dose rate coverage for OARs. ABSTRACT: Purpose: While transmission proton beams have been demonstrated to achieve ultra-high dose rate FLASH therapy delivery, they are unable to spare normal tissues distal to the target. This study aims to compare FLASH treatment planning using single energy Bragg peak proton beams versus transmission proton beams in lung tumors and to evaluate Bragg peak plan optimization, characterize plan quality, and quantify organ-at-risk (OAR) sparing. Materials and Methods: Both Bragg peak and transmission plans were optimized using an in-house platform for 10 consecutive lung patients previously treated with proton stereotactic body radiation therapy (SBRT). To bring the dose rate up to the FLASH-RT threshold, Bragg peak plans with a minimum MU/spot of 1200 and transmission plans with a minimum MU/spot of 400 were developed. Two common prescriptions, 34 Gy in 1 fraction and 54 Gy in 3 fractions, were studied with the same beam arrangement for both Bragg peak and transmission plans (n = 40 plans). RTOG 0915 dosimetry metrics and dose rate metrics based on different dose rate calculations, including average dose rate (ADR), dose-averaged dose rate (DADR), and dose threshold dose rate (DTDR), were investigated. We then evaluated the effect of beam angular optimization on the Bragg peak plans to explore the potential for superior OAR sparing. Results: Bragg peak plans significantly reduced doses to several OAR dose parameters, including lung V(7.4Gy) and V(7Gy) by 32.0% (p < 0.01) and 30.4% (p < 0.01) for 34Gy/fx plans, respectively; and by 40.8% (p < 0.01) and 41.2% (p < 0.01) for 18Gy/fx plans, respectively, compared with transmission plans. Bragg peak plans have ~3% less in DADR and ~10% differences in mean OARs in DTDR and DADR relative to transmission plans due to the larger portion of lower dose regions of Bragg peak plans. With angular optimization, optimized Bragg peak plans can further reduce the lung V(7Gy) by 20.7% (p < 0.01) and V(7.4Gy) by 19.7% (p < 0.01) compared with Bragg peak plans without angular optimization while achieving a similar 3D dose rate distribution. Conclusion: The single-energy Bragg peak plans achieve superior dosimetry performances in OARs to transmission plans with comparable dose rate performances for lung cancer FLASH therapy. Beam angle optimization can further improve the OAR dosimetry parameters with similar 3D FLASH dose rate coverage.
format Online
Article
Text
id pubmed-8616118
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86161182021-11-26 A Novel Proton Pencil Beam Scanning FLASH RT Delivery Method Enables Optimal OAR Sparing and Ultra-High Dose Rate Delivery: A Comprehensive Dosimetry Study for Lung Tumors Wei, Shouyi Lin, Haibo Choi, J. Isabelle Simone, Charles B. Kang, Minglei Cancers (Basel) Article SIMPLE SUMMARY: This study attempts to answer a novel and clinically relevant question of the value of Bragg-peak-based FLASH planning for lung tumors. Most existing studies and literature are limited to using transmission proton beams at ultra-high dose rates, resulting in unnecessary irradiation exposure to normal tissues beyond the target volume. By combining a new hardware design (universal range shifter and range compensator) and an inverse planning system, the novel Bragg peak method makes the Bragg-peak-based FLASH planning possible. The treatment planning study and dosimetry comparison between single-energy proton Bragg peak beams and transmission proton beams demonstrated superior performances in OAR sparing and comparable FLASH dose rate of the Bragg peak FLASH. Beam angle optimization can further improve Bragg peak FLASH dosimetry performance while maintaining the similar 3D FLASH dose rate coverage for OARs. ABSTRACT: Purpose: While transmission proton beams have been demonstrated to achieve ultra-high dose rate FLASH therapy delivery, they are unable to spare normal tissues distal to the target. This study aims to compare FLASH treatment planning using single energy Bragg peak proton beams versus transmission proton beams in lung tumors and to evaluate Bragg peak plan optimization, characterize plan quality, and quantify organ-at-risk (OAR) sparing. Materials and Methods: Both Bragg peak and transmission plans were optimized using an in-house platform for 10 consecutive lung patients previously treated with proton stereotactic body radiation therapy (SBRT). To bring the dose rate up to the FLASH-RT threshold, Bragg peak plans with a minimum MU/spot of 1200 and transmission plans with a minimum MU/spot of 400 were developed. Two common prescriptions, 34 Gy in 1 fraction and 54 Gy in 3 fractions, were studied with the same beam arrangement for both Bragg peak and transmission plans (n = 40 plans). RTOG 0915 dosimetry metrics and dose rate metrics based on different dose rate calculations, including average dose rate (ADR), dose-averaged dose rate (DADR), and dose threshold dose rate (DTDR), were investigated. We then evaluated the effect of beam angular optimization on the Bragg peak plans to explore the potential for superior OAR sparing. Results: Bragg peak plans significantly reduced doses to several OAR dose parameters, including lung V(7.4Gy) and V(7Gy) by 32.0% (p < 0.01) and 30.4% (p < 0.01) for 34Gy/fx plans, respectively; and by 40.8% (p < 0.01) and 41.2% (p < 0.01) for 18Gy/fx plans, respectively, compared with transmission plans. Bragg peak plans have ~3% less in DADR and ~10% differences in mean OARs in DTDR and DADR relative to transmission plans due to the larger portion of lower dose regions of Bragg peak plans. With angular optimization, optimized Bragg peak plans can further reduce the lung V(7Gy) by 20.7% (p < 0.01) and V(7.4Gy) by 19.7% (p < 0.01) compared with Bragg peak plans without angular optimization while achieving a similar 3D dose rate distribution. Conclusion: The single-energy Bragg peak plans achieve superior dosimetry performances in OARs to transmission plans with comparable dose rate performances for lung cancer FLASH therapy. Beam angle optimization can further improve the OAR dosimetry parameters with similar 3D FLASH dose rate coverage. MDPI 2021-11-18 /pmc/articles/PMC8616118/ /pubmed/34830946 http://dx.doi.org/10.3390/cancers13225790 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wei, Shouyi
Lin, Haibo
Choi, J. Isabelle
Simone, Charles B.
Kang, Minglei
A Novel Proton Pencil Beam Scanning FLASH RT Delivery Method Enables Optimal OAR Sparing and Ultra-High Dose Rate Delivery: A Comprehensive Dosimetry Study for Lung Tumors
title A Novel Proton Pencil Beam Scanning FLASH RT Delivery Method Enables Optimal OAR Sparing and Ultra-High Dose Rate Delivery: A Comprehensive Dosimetry Study for Lung Tumors
title_full A Novel Proton Pencil Beam Scanning FLASH RT Delivery Method Enables Optimal OAR Sparing and Ultra-High Dose Rate Delivery: A Comprehensive Dosimetry Study for Lung Tumors
title_fullStr A Novel Proton Pencil Beam Scanning FLASH RT Delivery Method Enables Optimal OAR Sparing and Ultra-High Dose Rate Delivery: A Comprehensive Dosimetry Study for Lung Tumors
title_full_unstemmed A Novel Proton Pencil Beam Scanning FLASH RT Delivery Method Enables Optimal OAR Sparing and Ultra-High Dose Rate Delivery: A Comprehensive Dosimetry Study for Lung Tumors
title_short A Novel Proton Pencil Beam Scanning FLASH RT Delivery Method Enables Optimal OAR Sparing and Ultra-High Dose Rate Delivery: A Comprehensive Dosimetry Study for Lung Tumors
title_sort novel proton pencil beam scanning flash rt delivery method enables optimal oar sparing and ultra-high dose rate delivery: a comprehensive dosimetry study for lung tumors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8616118/
https://www.ncbi.nlm.nih.gov/pubmed/34830946
http://dx.doi.org/10.3390/cancers13225790
work_keys_str_mv AT weishouyi anovelprotonpencilbeamscanningflashrtdeliverymethodenablesoptimaloarsparingandultrahighdoseratedeliveryacomprehensivedosimetrystudyforlungtumors
AT linhaibo anovelprotonpencilbeamscanningflashrtdeliverymethodenablesoptimaloarsparingandultrahighdoseratedeliveryacomprehensivedosimetrystudyforlungtumors
AT choijisabelle anovelprotonpencilbeamscanningflashrtdeliverymethodenablesoptimaloarsparingandultrahighdoseratedeliveryacomprehensivedosimetrystudyforlungtumors
AT simonecharlesb anovelprotonpencilbeamscanningflashrtdeliverymethodenablesoptimaloarsparingandultrahighdoseratedeliveryacomprehensivedosimetrystudyforlungtumors
AT kangminglei anovelprotonpencilbeamscanningflashrtdeliverymethodenablesoptimaloarsparingandultrahighdoseratedeliveryacomprehensivedosimetrystudyforlungtumors
AT weishouyi novelprotonpencilbeamscanningflashrtdeliverymethodenablesoptimaloarsparingandultrahighdoseratedeliveryacomprehensivedosimetrystudyforlungtumors
AT linhaibo novelprotonpencilbeamscanningflashrtdeliverymethodenablesoptimaloarsparingandultrahighdoseratedeliveryacomprehensivedosimetrystudyforlungtumors
AT choijisabelle novelprotonpencilbeamscanningflashrtdeliverymethodenablesoptimaloarsparingandultrahighdoseratedeliveryacomprehensivedosimetrystudyforlungtumors
AT simonecharlesb novelprotonpencilbeamscanningflashrtdeliverymethodenablesoptimaloarsparingandultrahighdoseratedeliveryacomprehensivedosimetrystudyforlungtumors
AT kangminglei novelprotonpencilbeamscanningflashrtdeliverymethodenablesoptimaloarsparingandultrahighdoseratedeliveryacomprehensivedosimetrystudyforlungtumors