Cargando…

Artifact reduction of coaxial needles in magnetic resonance imaging-guided abdominal interventions at 1.5 T: a phantom study

Needle artifacts pose a major limitation for MRI-guided interventions, as they impact the visually perceived needle size and needle-to-target-distance. The objective of this agar liver phantom study was to establish an experimental basis to understand and reduce needle artifact formation during MRI-...

Descripción completa

Detalles Bibliográficos
Autores principales: Schmidt, Vanessa Franziska, Arnone, Federica, Dietrich, Olaf, Seidensticker, Max, Armbruster, Marco, Ricke, Jens, Kazmierczak, Philipp Maximilian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617285/
https://www.ncbi.nlm.nih.gov/pubmed/34824361
http://dx.doi.org/10.1038/s41598-021-02434-5
_version_ 1784604490913021952
author Schmidt, Vanessa Franziska
Arnone, Federica
Dietrich, Olaf
Seidensticker, Max
Armbruster, Marco
Ricke, Jens
Kazmierczak, Philipp Maximilian
author_facet Schmidt, Vanessa Franziska
Arnone, Federica
Dietrich, Olaf
Seidensticker, Max
Armbruster, Marco
Ricke, Jens
Kazmierczak, Philipp Maximilian
author_sort Schmidt, Vanessa Franziska
collection PubMed
description Needle artifacts pose a major limitation for MRI-guided interventions, as they impact the visually perceived needle size and needle-to-target-distance. The objective of this agar liver phantom study was to establish an experimental basis to understand and reduce needle artifact formation during MRI-guided abdominal interventions. Using a vendor-specific prototype fluoroscopic T1-weighted gradient echo sequence with real-time multiplanar acquisition at 1.5 T, the influence of 6 parameters (flip angle, bandwidth, matrix, slice thickness, read-out direction, intervention angle relative to B(0)) on artifact formation of 4 different coaxial MR-compatible coaxial needles (Nitinol, 16G–22G) was investigated. As one parameter was modified, the others remained constant. For each individual parameter variation, 2 independent and blinded readers rated artifact diameters at 2 predefined positions (15 mm distance from the perceived needle tip and at 50% of the needle length). Differences between the experimental subgroups were assessed by Bonferroni-corrected non-parametric tests. Correlations between continuous variables were expressed by the Bravais–Pearson coefficient and interrater reliability was quantified using the intraclass classification coefficient. Needle artifact size increased gradually with increasing flip angles (p = 0.002) as well as increasing intervention angles (p < 0.001). Artifact diameters differed significantly between the chosen matrix sizes (p = 0.002) while modifying bandwidth, readout direction, and slice thickness showed no significant differences. Interrater reliability was high (intraclass correlation coefficient 0.776–0.910). To minimize needle artifacts in MRI-guided abdominal interventions while maintaining optimal visibility of the coaxial needle, we suggest medium-range flip angles and low intervention angles relative to B(0).
format Online
Article
Text
id pubmed-8617285
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-86172852021-11-29 Artifact reduction of coaxial needles in magnetic resonance imaging-guided abdominal interventions at 1.5 T: a phantom study Schmidt, Vanessa Franziska Arnone, Federica Dietrich, Olaf Seidensticker, Max Armbruster, Marco Ricke, Jens Kazmierczak, Philipp Maximilian Sci Rep Article Needle artifacts pose a major limitation for MRI-guided interventions, as they impact the visually perceived needle size and needle-to-target-distance. The objective of this agar liver phantom study was to establish an experimental basis to understand and reduce needle artifact formation during MRI-guided abdominal interventions. Using a vendor-specific prototype fluoroscopic T1-weighted gradient echo sequence with real-time multiplanar acquisition at 1.5 T, the influence of 6 parameters (flip angle, bandwidth, matrix, slice thickness, read-out direction, intervention angle relative to B(0)) on artifact formation of 4 different coaxial MR-compatible coaxial needles (Nitinol, 16G–22G) was investigated. As one parameter was modified, the others remained constant. For each individual parameter variation, 2 independent and blinded readers rated artifact diameters at 2 predefined positions (15 mm distance from the perceived needle tip and at 50% of the needle length). Differences between the experimental subgroups were assessed by Bonferroni-corrected non-parametric tests. Correlations between continuous variables were expressed by the Bravais–Pearson coefficient and interrater reliability was quantified using the intraclass classification coefficient. Needle artifact size increased gradually with increasing flip angles (p = 0.002) as well as increasing intervention angles (p < 0.001). Artifact diameters differed significantly between the chosen matrix sizes (p = 0.002) while modifying bandwidth, readout direction, and slice thickness showed no significant differences. Interrater reliability was high (intraclass correlation coefficient 0.776–0.910). To minimize needle artifacts in MRI-guided abdominal interventions while maintaining optimal visibility of the coaxial needle, we suggest medium-range flip angles and low intervention angles relative to B(0). Nature Publishing Group UK 2021-11-25 /pmc/articles/PMC8617285/ /pubmed/34824361 http://dx.doi.org/10.1038/s41598-021-02434-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Schmidt, Vanessa Franziska
Arnone, Federica
Dietrich, Olaf
Seidensticker, Max
Armbruster, Marco
Ricke, Jens
Kazmierczak, Philipp Maximilian
Artifact reduction of coaxial needles in magnetic resonance imaging-guided abdominal interventions at 1.5 T: a phantom study
title Artifact reduction of coaxial needles in magnetic resonance imaging-guided abdominal interventions at 1.5 T: a phantom study
title_full Artifact reduction of coaxial needles in magnetic resonance imaging-guided abdominal interventions at 1.5 T: a phantom study
title_fullStr Artifact reduction of coaxial needles in magnetic resonance imaging-guided abdominal interventions at 1.5 T: a phantom study
title_full_unstemmed Artifact reduction of coaxial needles in magnetic resonance imaging-guided abdominal interventions at 1.5 T: a phantom study
title_short Artifact reduction of coaxial needles in magnetic resonance imaging-guided abdominal interventions at 1.5 T: a phantom study
title_sort artifact reduction of coaxial needles in magnetic resonance imaging-guided abdominal interventions at 1.5 t: a phantom study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617285/
https://www.ncbi.nlm.nih.gov/pubmed/34824361
http://dx.doi.org/10.1038/s41598-021-02434-5
work_keys_str_mv AT schmidtvanessafranziska artifactreductionofcoaxialneedlesinmagneticresonanceimagingguidedabdominalinterventionsat15taphantomstudy
AT arnonefederica artifactreductionofcoaxialneedlesinmagneticresonanceimagingguidedabdominalinterventionsat15taphantomstudy
AT dietricholaf artifactreductionofcoaxialneedlesinmagneticresonanceimagingguidedabdominalinterventionsat15taphantomstudy
AT seidenstickermax artifactreductionofcoaxialneedlesinmagneticresonanceimagingguidedabdominalinterventionsat15taphantomstudy
AT armbrustermarco artifactreductionofcoaxialneedlesinmagneticresonanceimagingguidedabdominalinterventionsat15taphantomstudy
AT rickejens artifactreductionofcoaxialneedlesinmagneticresonanceimagingguidedabdominalinterventionsat15taphantomstudy
AT kazmierczakphilippmaximilian artifactreductionofcoaxialneedlesinmagneticresonanceimagingguidedabdominalinterventionsat15taphantomstudy