Cargando…
When Echocardiography Fails, Intravascular Ultrasound as an Alternative for Adequate Graft Patency in Hybrid Elephant Trunk Surgery
Aortic pathology is a common cardiovascular disease in the US. Transesophageal Echocardiogram is an invaluable imaging modality in the management of aortic pathology in perioperative setting. Intravascular ultrasound can assess coronary obstruction during coronary interventions and can be used in en...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617390/ https://www.ncbi.nlm.nih.gov/pubmed/34747764 http://dx.doi.org/10.4103/aca.ACA_131_20 |
_version_ | 1784604515739107328 |
---|---|
author | Thida, Fnu Carvajal, Tomas Unai, Shinya Bustamante, Sergio E |
author_facet | Thida, Fnu Carvajal, Tomas Unai, Shinya Bustamante, Sergio E |
author_sort | Thida, Fnu |
collection | PubMed |
description | Aortic pathology is a common cardiovascular disease in the US. Transesophageal Echocardiogram is an invaluable imaging modality in the management of aortic pathology in perioperative setting. Intravascular ultrasound can assess coronary obstruction during coronary interventions and can be used in endovascular aneurysm repair. A 54-year-old male underwent Hybrid Elephant Trunk Surgery, for complex open aorta repair. There was functional confirmation graft patency via the femoral arterial line tracing, there was surgical confirmation via visual and physical inspection of graft, but there was lacking anatomical confirmation. Epiaortic ultrasound reassured the graft patency at level of the arch. However, transesophageal echocardiogram was not reassuring for adequate anatomical confirmation of patency. Intravascular ultrasound was used for anatomical confirmation of graft patency and position. This technology provides real time graft patency and is a great tool in open aorta reconstruction surgery. |
format | Online Article Text |
id | pubmed-8617390 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-86173902021-12-13 When Echocardiography Fails, Intravascular Ultrasound as an Alternative for Adequate Graft Patency in Hybrid Elephant Trunk Surgery Thida, Fnu Carvajal, Tomas Unai, Shinya Bustamante, Sergio E Ann Card Anaesth Interesting Image Aortic pathology is a common cardiovascular disease in the US. Transesophageal Echocardiogram is an invaluable imaging modality in the management of aortic pathology in perioperative setting. Intravascular ultrasound can assess coronary obstruction during coronary interventions and can be used in endovascular aneurysm repair. A 54-year-old male underwent Hybrid Elephant Trunk Surgery, for complex open aorta repair. There was functional confirmation graft patency via the femoral arterial line tracing, there was surgical confirmation via visual and physical inspection of graft, but there was lacking anatomical confirmation. Epiaortic ultrasound reassured the graft patency at level of the arch. However, transesophageal echocardiogram was not reassuring for adequate anatomical confirmation of patency. Intravascular ultrasound was used for anatomical confirmation of graft patency and position. This technology provides real time graft patency and is a great tool in open aorta reconstruction surgery. Wolters Kluwer - Medknow 2021 2021-10-18 /pmc/articles/PMC8617390/ /pubmed/34747764 http://dx.doi.org/10.4103/aca.ACA_131_20 Text en Copyright: © 2021 Annals of Cardiac Anaesthesia https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Interesting Image Thida, Fnu Carvajal, Tomas Unai, Shinya Bustamante, Sergio E When Echocardiography Fails, Intravascular Ultrasound as an Alternative for Adequate Graft Patency in Hybrid Elephant Trunk Surgery |
title | When Echocardiography Fails, Intravascular Ultrasound as an Alternative for Adequate Graft Patency in Hybrid Elephant Trunk Surgery |
title_full | When Echocardiography Fails, Intravascular Ultrasound as an Alternative for Adequate Graft Patency in Hybrid Elephant Trunk Surgery |
title_fullStr | When Echocardiography Fails, Intravascular Ultrasound as an Alternative for Adequate Graft Patency in Hybrid Elephant Trunk Surgery |
title_full_unstemmed | When Echocardiography Fails, Intravascular Ultrasound as an Alternative for Adequate Graft Patency in Hybrid Elephant Trunk Surgery |
title_short | When Echocardiography Fails, Intravascular Ultrasound as an Alternative for Adequate Graft Patency in Hybrid Elephant Trunk Surgery |
title_sort | when echocardiography fails, intravascular ultrasound as an alternative for adequate graft patency in hybrid elephant trunk surgery |
topic | Interesting Image |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617390/ https://www.ncbi.nlm.nih.gov/pubmed/34747764 http://dx.doi.org/10.4103/aca.ACA_131_20 |
work_keys_str_mv | AT thidafnu whenechocardiographyfailsintravascularultrasoundasanalternativeforadequategraftpatencyinhybridelephanttrunksurgery AT carvajaltomas whenechocardiographyfailsintravascularultrasoundasanalternativeforadequategraftpatencyinhybridelephanttrunksurgery AT unaishinya whenechocardiographyfailsintravascularultrasoundasanalternativeforadequategraftpatencyinhybridelephanttrunksurgery AT bustamantesergioe whenechocardiographyfailsintravascularultrasoundasanalternativeforadequategraftpatencyinhybridelephanttrunksurgery |