Cargando…

Comparison of quality of bone and insertion torque values of early implants placed at 6 and 8 weeks in sockets preserved with advanced platelet-rich fibrin: A randomized controlled trial

AIM: Successful functional and esthetic rehabilitation of edentulous jaws with implants depends on the optimal timing of placement, surgical protocol, materials used, cost-effectiveness, and satisfying patient needs. Increasing demand for shorter treatment times necessitates the immediate placement...

Descripción completa

Detalles Bibliográficos
Autores principales: Chary, Nukalamarri Om Brahma Prasad, Raju, M Satyanarayana, Sajjan, M C Suresh, Gottumukkala, Sruthima NVS, Manyam, Ravikanth
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617450/
https://www.ncbi.nlm.nih.gov/pubmed/34810364
http://dx.doi.org/10.4103/jips.jips_331_21
_version_ 1784604523690459136
author Chary, Nukalamarri Om Brahma Prasad
Raju, M Satyanarayana
Sajjan, M C Suresh
Gottumukkala, Sruthima NVS
Manyam, Ravikanth
author_facet Chary, Nukalamarri Om Brahma Prasad
Raju, M Satyanarayana
Sajjan, M C Suresh
Gottumukkala, Sruthima NVS
Manyam, Ravikanth
author_sort Chary, Nukalamarri Om Brahma Prasad
collection PubMed
description AIM: Successful functional and esthetic rehabilitation of edentulous jaws with implants depends on the optimal timing of placement, surgical protocol, materials used, cost-effectiveness, and satisfying patient needs. Increasing demand for shorter treatment times necessitates the immediate placement protocol. However, researchers have demonstrateda higher failure rate. A-PRF (Advanced platelet-rich fibrin) has exhibited accelerated bone regeneration potential. Early implant placement with a limited healing period, along with A-PRF, can be beneficial over conventional and immediate implant placement. SETTINGS AND DESIGN: This prospective randomized clinical trial aims to assess the outcome of early implant placement in sockets preserved using A-PRF at six weeks and eight weeks of post-extraction. Two groups of 10 participantseach were formed. All patients underwent atraumatic extraction and socket preservation using A-PRF. MATERIALS AND METHODS: A Partial-thickness pedicle graft was raised, and the extraction socket wasclosed. Implants wereplaced in at six and eight weeks of post-extraction in group A group B, respectively. The histomorphometric analysisassessedthe bone quality present at the timeof surgery. The insertion torque values were recorded during implant placement. STATISTICAL ANALYSIS USED: The obtained data were statistically analyzed using parametric tests, namely independent T-test for intergroup comparison. RESULTS: T-test for torque values indicated a significantly higher torque value at eight weeks. The meanhistomorphometric value showeda significantly higher percentage of bone formation at eight weeks than at six weeks (P = 0.03). CONCLUSION: Within the study's limitations, early implant placement in extraction sockets preserved with A-PRF had significantly higher insertion torque values and predictable bone at eight weeks compared to six weeks.
format Online
Article
Text
id pubmed-8617450
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-86174502022-10-01 Comparison of quality of bone and insertion torque values of early implants placed at 6 and 8 weeks in sockets preserved with advanced platelet-rich fibrin: A randomized controlled trial Chary, Nukalamarri Om Brahma Prasad Raju, M Satyanarayana Sajjan, M C Suresh Gottumukkala, Sruthima NVS Manyam, Ravikanth J Indian Prosthodont Soc Original Article AIM: Successful functional and esthetic rehabilitation of edentulous jaws with implants depends on the optimal timing of placement, surgical protocol, materials used, cost-effectiveness, and satisfying patient needs. Increasing demand for shorter treatment times necessitates the immediate placement protocol. However, researchers have demonstrateda higher failure rate. A-PRF (Advanced platelet-rich fibrin) has exhibited accelerated bone regeneration potential. Early implant placement with a limited healing period, along with A-PRF, can be beneficial over conventional and immediate implant placement. SETTINGS AND DESIGN: This prospective randomized clinical trial aims to assess the outcome of early implant placement in sockets preserved using A-PRF at six weeks and eight weeks of post-extraction. Two groups of 10 participantseach were formed. All patients underwent atraumatic extraction and socket preservation using A-PRF. MATERIALS AND METHODS: A Partial-thickness pedicle graft was raised, and the extraction socket wasclosed. Implants wereplaced in at six and eight weeks of post-extraction in group A group B, respectively. The histomorphometric analysisassessedthe bone quality present at the timeof surgery. The insertion torque values were recorded during implant placement. STATISTICAL ANALYSIS USED: The obtained data were statistically analyzed using parametric tests, namely independent T-test for intergroup comparison. RESULTS: T-test for torque values indicated a significantly higher torque value at eight weeks. The meanhistomorphometric value showeda significantly higher percentage of bone formation at eight weeks than at six weeks (P = 0.03). CONCLUSION: Within the study's limitations, early implant placement in extraction sockets preserved with A-PRF had significantly higher insertion torque values and predictable bone at eight weeks compared to six weeks. Wolters Kluwer - Medknow 2021 2021-11-09 /pmc/articles/PMC8617450/ /pubmed/34810364 http://dx.doi.org/10.4103/jips.jips_331_21 Text en Copyright: © 2021 The Journal of Indian Prosthodontic Society https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Chary, Nukalamarri Om Brahma Prasad
Raju, M Satyanarayana
Sajjan, M C Suresh
Gottumukkala, Sruthima NVS
Manyam, Ravikanth
Comparison of quality of bone and insertion torque values of early implants placed at 6 and 8 weeks in sockets preserved with advanced platelet-rich fibrin: A randomized controlled trial
title Comparison of quality of bone and insertion torque values of early implants placed at 6 and 8 weeks in sockets preserved with advanced platelet-rich fibrin: A randomized controlled trial
title_full Comparison of quality of bone and insertion torque values of early implants placed at 6 and 8 weeks in sockets preserved with advanced platelet-rich fibrin: A randomized controlled trial
title_fullStr Comparison of quality of bone and insertion torque values of early implants placed at 6 and 8 weeks in sockets preserved with advanced platelet-rich fibrin: A randomized controlled trial
title_full_unstemmed Comparison of quality of bone and insertion torque values of early implants placed at 6 and 8 weeks in sockets preserved with advanced platelet-rich fibrin: A randomized controlled trial
title_short Comparison of quality of bone and insertion torque values of early implants placed at 6 and 8 weeks in sockets preserved with advanced platelet-rich fibrin: A randomized controlled trial
title_sort comparison of quality of bone and insertion torque values of early implants placed at 6 and 8 weeks in sockets preserved with advanced platelet-rich fibrin: a randomized controlled trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617450/
https://www.ncbi.nlm.nih.gov/pubmed/34810364
http://dx.doi.org/10.4103/jips.jips_331_21
work_keys_str_mv AT charynukalamarriombrahmaprasad comparisonofqualityofboneandinsertiontorquevaluesofearlyimplantsplacedat6and8weeksinsocketspreservedwithadvancedplateletrichfibrinarandomizedcontrolledtrial
AT rajumsatyanarayana comparisonofqualityofboneandinsertiontorquevaluesofearlyimplantsplacedat6and8weeksinsocketspreservedwithadvancedplateletrichfibrinarandomizedcontrolledtrial
AT sajjanmcsuresh comparisonofqualityofboneandinsertiontorquevaluesofearlyimplantsplacedat6and8weeksinsocketspreservedwithadvancedplateletrichfibrinarandomizedcontrolledtrial
AT gottumukkalasruthimanvs comparisonofqualityofboneandinsertiontorquevaluesofearlyimplantsplacedat6and8weeksinsocketspreservedwithadvancedplateletrichfibrinarandomizedcontrolledtrial
AT manyamravikanth comparisonofqualityofboneandinsertiontorquevaluesofearlyimplantsplacedat6and8weeksinsocketspreservedwithadvancedplateletrichfibrinarandomizedcontrolledtrial