The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study

AIM: Bacterial micro leakage at implant-abutment interface under functional loading is an important factor, may lead to crestal bone loss and affect the long term success of dental implants. Due to the limited studies about the implant systems with a connection of Slip joint design, this study aimed...

Descripción completa

Detalles Bibliográficos
Autores principales: Amjadi, Mehrak, Khajavi, Azadeh, Youssefi, Navid, Barjini, Negar, Kazemi, Zahra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617451/
https://www.ncbi.nlm.nih.gov/pubmed/34810371
http://dx.doi.org/10.4103/jips.jips_96_21
_version_ 1784604523924291584
author Amjadi, Mehrak
Khajavi, Azadeh
Youssefi, Navid
Barjini, Negar
Kazemi, Zahra
author_facet Amjadi, Mehrak
Khajavi, Azadeh
Youssefi, Navid
Barjini, Negar
Kazemi, Zahra
author_sort Amjadi, Mehrak
collection PubMed
description AIM: Bacterial micro leakage at implant-abutment interface under functional loading is an important factor, may lead to crestal bone loss and affect the long term success of dental implants. Due to the limited studies about the implant systems with a connection of Slip joint design, this study aimed to evaluate the effect of dynamic loading on bacterial leakage at the implant-abutment interface with slip joint connection. SETTINGS AND DESIGN: In vitro- comparative study. MATERIALS AND METHODS: A total of 20 implants and abutments with slip joint connections (Tapered Screw-Vent, 3.7 mm ×10 mm, Zimmer Dental, USA) was examined and depends on using functional loading were divided into two groups; loaded and unloaded. Initially, 10 μl of Brain Heart Infusion (BHI) culture broth was pipetted to the internal lumen of each implant, then the abutments were tightened to the fixtures and crowns were cemented. In the unloaded group, samples were immersed in E-Coli suspension for 5 days. In the loaded group, samples were immersed in microbial suspension under 500000 cycles using a cyclic load device. Following disconnection of fixtures and abutments, microbial samples were taken from the internal lumen of implants and colonies were counted. Data were analyzed using. STATISTICAL ANALYSIS USED: Mann-Whitney statistical test, SPSS version 24. RESULTS: The mean rate of micro leakage in unloaded and loaded groups was 4000 CFU/ml and 27000 ± 31640 CFU/ml respectively. Bacterial colonies grew in 10% of unloaded samples and 50% of loaded samples. This difference was statistically significant. (P < 0.05) CONCLUSIONS: Microbial micro leakage at the implant-abutment interface with slip joint design increased significantly after functional loading.
format Online
Article
Text
id pubmed-8617451
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-86174512022-10-01 The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study Amjadi, Mehrak Khajavi, Azadeh Youssefi, Navid Barjini, Negar Kazemi, Zahra J Indian Prosthodont Soc Original Article AIM: Bacterial micro leakage at implant-abutment interface under functional loading is an important factor, may lead to crestal bone loss and affect the long term success of dental implants. Due to the limited studies about the implant systems with a connection of Slip joint design, this study aimed to evaluate the effect of dynamic loading on bacterial leakage at the implant-abutment interface with slip joint connection. SETTINGS AND DESIGN: In vitro- comparative study. MATERIALS AND METHODS: A total of 20 implants and abutments with slip joint connections (Tapered Screw-Vent, 3.7 mm ×10 mm, Zimmer Dental, USA) was examined and depends on using functional loading were divided into two groups; loaded and unloaded. Initially, 10 μl of Brain Heart Infusion (BHI) culture broth was pipetted to the internal lumen of each implant, then the abutments were tightened to the fixtures and crowns were cemented. In the unloaded group, samples were immersed in E-Coli suspension for 5 days. In the loaded group, samples were immersed in microbial suspension under 500000 cycles using a cyclic load device. Following disconnection of fixtures and abutments, microbial samples were taken from the internal lumen of implants and colonies were counted. Data were analyzed using. STATISTICAL ANALYSIS USED: Mann-Whitney statistical test, SPSS version 24. RESULTS: The mean rate of micro leakage in unloaded and loaded groups was 4000 CFU/ml and 27000 ± 31640 CFU/ml respectively. Bacterial colonies grew in 10% of unloaded samples and 50% of loaded samples. This difference was statistically significant. (P < 0.05) CONCLUSIONS: Microbial micro leakage at the implant-abutment interface with slip joint design increased significantly after functional loading. Wolters Kluwer - Medknow 2021 2021-11-09 /pmc/articles/PMC8617451/ /pubmed/34810371 http://dx.doi.org/10.4103/jips.jips_96_21 Text en Copyright: © 2021 The Journal of Indian Prosthodontic Society https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Amjadi, Mehrak
Khajavi, Azadeh
Youssefi, Navid
Barjini, Negar
Kazemi, Zahra
The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study
title The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study
title_full The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study
title_fullStr The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study
title_full_unstemmed The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study
title_short The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study
title_sort effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617451/
https://www.ncbi.nlm.nih.gov/pubmed/34810371
http://dx.doi.org/10.4103/jips.jips_96_21
work_keys_str_mv AT amjadimehrak theeffectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy
AT khajaviazadeh theeffectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy
AT youssefinavid theeffectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy
AT barjininegar theeffectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy
AT kazemizahra theeffectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy
AT amjadimehrak effectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy
AT khajaviazadeh effectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy
AT youssefinavid effectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy
AT barjininegar effectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy
AT kazemizahra effectofdynamicloadingonbacterialmicroleakageofthedentalimplantfixtureabutmentinterfaceaninvitrostudy