Cargando…

Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study

AIM: The Aim of the study was to evaluate the reproducibility of condylar inclination values obtained using three different interocclusal recording materials in Hanau Wide-Vue semi-adjustable articulator and to compare those values of condylar inclination with panoramic radiographic images. SETTINGS...

Descripción completa

Detalles Bibliográficos
Autores principales: Keerthana, S.R., Mohammed, H.S., Hariprasad, A., Anand, M., Ayesha, Syeda
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617454/
https://www.ncbi.nlm.nih.gov/pubmed/34810368
http://dx.doi.org/10.4103/jips.jips_239_21
_version_ 1784604524641517568
author Keerthana, S.R.
Mohammed, H.S.
Hariprasad, A.
Anand, M.
Ayesha, Syeda
author_facet Keerthana, S.R.
Mohammed, H.S.
Hariprasad, A.
Anand, M.
Ayesha, Syeda
author_sort Keerthana, S.R.
collection PubMed
description AIM: The Aim of the study was to evaluate the reproducibility of condylar inclination values obtained using three different interocclusal recording materials in Hanau Wide-Vue semi-adjustable articulator and to compare those values of condylar inclination with panoramic radiographic images. SETTINGS AND DESIGN: In Vivo Comparative study. MATERIALS AND METHODS: The clinical trial was carried out in the Department of Prosthodontics, M. R Ambedkar Dental College and Hospital, Bengaluru. A total of 30 dentulous subjects aged between 20 and 40 years were selected, without any signs and symptoms of temporomandibular joint disorders. With the help of a custom-made protrusive guide, protrusive records for three materials were made. These records were used for programming the articulator and the respective horizontal condylar inclination (HCI) value, and panoramic radiographs were made. The values obtained were statistically analyzed. STATISTICAL ANALYSIS USED: Independent t-test, multiple comparisons using Bonferroni method followed by Analysis of variances (ANOVA) were used. RESULTS: Among each pair of groups there exists a significant difference, i.e., the mean condylar inclination (degree) was found to be statistically significant between wax and polyvinyl siloxane (P < 0.01) as well as between wax and polyether (P < 0.01). No significant difference was observed between polyvinyl siloxane and polyether (P > 0.05). CONCLUSION: HCI values differed depending on the type of material employed. The study concluded that the protrusive condylar guidance angles obtained by panoramic radiograph can be used in programming the semi-adjustable articulator and among the materials polyether gave the highest Condylar Guidance values with less variability and wax gave lowest values with greater variation.
format Online
Article
Text
id pubmed-8617454
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-86174542022-10-01 Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study Keerthana, S.R. Mohammed, H.S. Hariprasad, A. Anand, M. Ayesha, Syeda J Indian Prosthodont Soc Original Article AIM: The Aim of the study was to evaluate the reproducibility of condylar inclination values obtained using three different interocclusal recording materials in Hanau Wide-Vue semi-adjustable articulator and to compare those values of condylar inclination with panoramic radiographic images. SETTINGS AND DESIGN: In Vivo Comparative study. MATERIALS AND METHODS: The clinical trial was carried out in the Department of Prosthodontics, M. R Ambedkar Dental College and Hospital, Bengaluru. A total of 30 dentulous subjects aged between 20 and 40 years were selected, without any signs and symptoms of temporomandibular joint disorders. With the help of a custom-made protrusive guide, protrusive records for three materials were made. These records were used for programming the articulator and the respective horizontal condylar inclination (HCI) value, and panoramic radiographs were made. The values obtained were statistically analyzed. STATISTICAL ANALYSIS USED: Independent t-test, multiple comparisons using Bonferroni method followed by Analysis of variances (ANOVA) were used. RESULTS: Among each pair of groups there exists a significant difference, i.e., the mean condylar inclination (degree) was found to be statistically significant between wax and polyvinyl siloxane (P < 0.01) as well as between wax and polyether (P < 0.01). No significant difference was observed between polyvinyl siloxane and polyether (P > 0.05). CONCLUSION: HCI values differed depending on the type of material employed. The study concluded that the protrusive condylar guidance angles obtained by panoramic radiograph can be used in programming the semi-adjustable articulator and among the materials polyether gave the highest Condylar Guidance values with less variability and wax gave lowest values with greater variation. Wolters Kluwer - Medknow 2021 2021-11-09 /pmc/articles/PMC8617454/ /pubmed/34810368 http://dx.doi.org/10.4103/jips.jips_239_21 Text en Copyright: © 2021 The Journal of Indian Prosthodontic Society https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Keerthana, S.R.
Mohammed, H.S.
Hariprasad, A.
Anand, M.
Ayesha, Syeda
Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study
title Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study
title_full Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study
title_fullStr Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study
title_full_unstemmed Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study
title_short Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study
title_sort comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: an in vivo study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617454/
https://www.ncbi.nlm.nih.gov/pubmed/34810368
http://dx.doi.org/10.4103/jips.jips_239_21
work_keys_str_mv AT keerthanasr comparativeevaluationofcondylarguidanceobtainedbythreedifferentinterocclusalrecordingmaterialsinasemiadjustablearticulatoranddigitalpanoramicradiographicimagesindentatepatientsaninvivostudy
AT mohammedhs comparativeevaluationofcondylarguidanceobtainedbythreedifferentinterocclusalrecordingmaterialsinasemiadjustablearticulatoranddigitalpanoramicradiographicimagesindentatepatientsaninvivostudy
AT hariprasada comparativeevaluationofcondylarguidanceobtainedbythreedifferentinterocclusalrecordingmaterialsinasemiadjustablearticulatoranddigitalpanoramicradiographicimagesindentatepatientsaninvivostudy
AT anandm comparativeevaluationofcondylarguidanceobtainedbythreedifferentinterocclusalrecordingmaterialsinasemiadjustablearticulatoranddigitalpanoramicradiographicimagesindentatepatientsaninvivostudy
AT ayeshasyeda comparativeevaluationofcondylarguidanceobtainedbythreedifferentinterocclusalrecordingmaterialsinasemiadjustablearticulatoranddigitalpanoramicradiographicimagesindentatepatientsaninvivostudy