Cargando…
Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study
AIM: The Aim of the study was to evaluate the reproducibility of condylar inclination values obtained using three different interocclusal recording materials in Hanau Wide-Vue semi-adjustable articulator and to compare those values of condylar inclination with panoramic radiographic images. SETTINGS...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617454/ https://www.ncbi.nlm.nih.gov/pubmed/34810368 http://dx.doi.org/10.4103/jips.jips_239_21 |
_version_ | 1784604524641517568 |
---|---|
author | Keerthana, S.R. Mohammed, H.S. Hariprasad, A. Anand, M. Ayesha, Syeda |
author_facet | Keerthana, S.R. Mohammed, H.S. Hariprasad, A. Anand, M. Ayesha, Syeda |
author_sort | Keerthana, S.R. |
collection | PubMed |
description | AIM: The Aim of the study was to evaluate the reproducibility of condylar inclination values obtained using three different interocclusal recording materials in Hanau Wide-Vue semi-adjustable articulator and to compare those values of condylar inclination with panoramic radiographic images. SETTINGS AND DESIGN: In Vivo Comparative study. MATERIALS AND METHODS: The clinical trial was carried out in the Department of Prosthodontics, M. R Ambedkar Dental College and Hospital, Bengaluru. A total of 30 dentulous subjects aged between 20 and 40 years were selected, without any signs and symptoms of temporomandibular joint disorders. With the help of a custom-made protrusive guide, protrusive records for three materials were made. These records were used for programming the articulator and the respective horizontal condylar inclination (HCI) value, and panoramic radiographs were made. The values obtained were statistically analyzed. STATISTICAL ANALYSIS USED: Independent t-test, multiple comparisons using Bonferroni method followed by Analysis of variances (ANOVA) were used. RESULTS: Among each pair of groups there exists a significant difference, i.e., the mean condylar inclination (degree) was found to be statistically significant between wax and polyvinyl siloxane (P < 0.01) as well as between wax and polyether (P < 0.01). No significant difference was observed between polyvinyl siloxane and polyether (P > 0.05). CONCLUSION: HCI values differed depending on the type of material employed. The study concluded that the protrusive condylar guidance angles obtained by panoramic radiograph can be used in programming the semi-adjustable articulator and among the materials polyether gave the highest Condylar Guidance values with less variability and wax gave lowest values with greater variation. |
format | Online Article Text |
id | pubmed-8617454 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-86174542022-10-01 Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study Keerthana, S.R. Mohammed, H.S. Hariprasad, A. Anand, M. Ayesha, Syeda J Indian Prosthodont Soc Original Article AIM: The Aim of the study was to evaluate the reproducibility of condylar inclination values obtained using three different interocclusal recording materials in Hanau Wide-Vue semi-adjustable articulator and to compare those values of condylar inclination with panoramic radiographic images. SETTINGS AND DESIGN: In Vivo Comparative study. MATERIALS AND METHODS: The clinical trial was carried out in the Department of Prosthodontics, M. R Ambedkar Dental College and Hospital, Bengaluru. A total of 30 dentulous subjects aged between 20 and 40 years were selected, without any signs and symptoms of temporomandibular joint disorders. With the help of a custom-made protrusive guide, protrusive records for three materials were made. These records were used for programming the articulator and the respective horizontal condylar inclination (HCI) value, and panoramic radiographs were made. The values obtained were statistically analyzed. STATISTICAL ANALYSIS USED: Independent t-test, multiple comparisons using Bonferroni method followed by Analysis of variances (ANOVA) were used. RESULTS: Among each pair of groups there exists a significant difference, i.e., the mean condylar inclination (degree) was found to be statistically significant between wax and polyvinyl siloxane (P < 0.01) as well as between wax and polyether (P < 0.01). No significant difference was observed between polyvinyl siloxane and polyether (P > 0.05). CONCLUSION: HCI values differed depending on the type of material employed. The study concluded that the protrusive condylar guidance angles obtained by panoramic radiograph can be used in programming the semi-adjustable articulator and among the materials polyether gave the highest Condylar Guidance values with less variability and wax gave lowest values with greater variation. Wolters Kluwer - Medknow 2021 2021-11-09 /pmc/articles/PMC8617454/ /pubmed/34810368 http://dx.doi.org/10.4103/jips.jips_239_21 Text en Copyright: © 2021 The Journal of Indian Prosthodontic Society https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Keerthana, S.R. Mohammed, H.S. Hariprasad, A. Anand, M. Ayesha, Syeda Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study |
title | Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study |
title_full | Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study |
title_fullStr | Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study |
title_full_unstemmed | Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study |
title_short | Comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: An in vivo study |
title_sort | comparative evaluation of condylar guidance obtained by three different interocclusal recording materials in a semi-adjustable articulator and digital panoramic radiographic images in dentate patients: an in vivo study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617454/ https://www.ncbi.nlm.nih.gov/pubmed/34810368 http://dx.doi.org/10.4103/jips.jips_239_21 |
work_keys_str_mv | AT keerthanasr comparativeevaluationofcondylarguidanceobtainedbythreedifferentinterocclusalrecordingmaterialsinasemiadjustablearticulatoranddigitalpanoramicradiographicimagesindentatepatientsaninvivostudy AT mohammedhs comparativeevaluationofcondylarguidanceobtainedbythreedifferentinterocclusalrecordingmaterialsinasemiadjustablearticulatoranddigitalpanoramicradiographicimagesindentatepatientsaninvivostudy AT hariprasada comparativeevaluationofcondylarguidanceobtainedbythreedifferentinterocclusalrecordingmaterialsinasemiadjustablearticulatoranddigitalpanoramicradiographicimagesindentatepatientsaninvivostudy AT anandm comparativeevaluationofcondylarguidanceobtainedbythreedifferentinterocclusalrecordingmaterialsinasemiadjustablearticulatoranddigitalpanoramicradiographicimagesindentatepatientsaninvivostudy AT ayeshasyeda comparativeevaluationofcondylarguidanceobtainedbythreedifferentinterocclusalrecordingmaterialsinasemiadjustablearticulatoranddigitalpanoramicradiographicimagesindentatepatientsaninvivostudy |