Cargando…

Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range

In order to design electromagnetic applicators for diagnostic and therapeutic applications, an adequate dielectric tissue model is required. In addition, tissue temperature will heavily influence the dielectric properties and the dielectric model should, thus, be extended to incorporate this tempera...

Descripción completa

Detalles Bibliográficos
Autores principales: Maenhout, Gertjan, Markovic, Tomislav, Nauwelaers, Bart
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617941/
https://www.ncbi.nlm.nih.gov/pubmed/34833716
http://dx.doi.org/10.3390/s21227644
_version_ 1784604627927302144
author Maenhout, Gertjan
Markovic, Tomislav
Nauwelaers, Bart
author_facet Maenhout, Gertjan
Markovic, Tomislav
Nauwelaers, Bart
author_sort Maenhout, Gertjan
collection PubMed
description In order to design electromagnetic applicators for diagnostic and therapeutic applications, an adequate dielectric tissue model is required. In addition, tissue temperature will heavily influence the dielectric properties and the dielectric model should, thus, be extended to incorporate this temperature dependence. Thus, this work has a dual purpose. Given the influence of temperature, dehydration, and probe-to-tissue contact pressure on dielectric measurements, this work will initially present the first setup to actively control and monitor the temperature of the sample, the dehydration rate of the investigated sample, and the applied probe-to-tissue contact pressure. Secondly, this work measured the dielectric properties of porcine muscle in the 0.5–40 GHz frequency range for temperatures from 20 °C to 45 °C. Following measurements, a single-pole Cole–Cole model is presented, in which the five Cole–Cole parameters ([Formula: see text] , [Formula: see text] , [Formula: see text] , [Formula: see text] , and [Formula: see text]) are given by a first order polynomial as function of tissue temperature. The dielectric model closely agrees with the limited dielectric models known in literature for muscle tissue at 37 °C, which makes it suited for the design of in vivo applicators. Furthermore, the dielectric data at 41–45 °C is of great importance for the design of hyperthermia applicators.
format Online
Article
Text
id pubmed-8617941
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86179412021-11-27 Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range Maenhout, Gertjan Markovic, Tomislav Nauwelaers, Bart Sensors (Basel) Article In order to design electromagnetic applicators for diagnostic and therapeutic applications, an adequate dielectric tissue model is required. In addition, tissue temperature will heavily influence the dielectric properties and the dielectric model should, thus, be extended to incorporate this temperature dependence. Thus, this work has a dual purpose. Given the influence of temperature, dehydration, and probe-to-tissue contact pressure on dielectric measurements, this work will initially present the first setup to actively control and monitor the temperature of the sample, the dehydration rate of the investigated sample, and the applied probe-to-tissue contact pressure. Secondly, this work measured the dielectric properties of porcine muscle in the 0.5–40 GHz frequency range for temperatures from 20 °C to 45 °C. Following measurements, a single-pole Cole–Cole model is presented, in which the five Cole–Cole parameters ([Formula: see text] , [Formula: see text] , [Formula: see text] , [Formula: see text] , and [Formula: see text]) are given by a first order polynomial as function of tissue temperature. The dielectric model closely agrees with the limited dielectric models known in literature for muscle tissue at 37 °C, which makes it suited for the design of in vivo applicators. Furthermore, the dielectric data at 41–45 °C is of great importance for the design of hyperthermia applicators. MDPI 2021-11-17 /pmc/articles/PMC8617941/ /pubmed/34833716 http://dx.doi.org/10.3390/s21227644 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Maenhout, Gertjan
Markovic, Tomislav
Nauwelaers, Bart
Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range
title Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range
title_full Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range
title_fullStr Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range
title_full_unstemmed Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range
title_short Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range
title_sort controlled measurement setup for ultra-wideband dielectric modeling of muscle tissue in 20–45 °c temperature range
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617941/
https://www.ncbi.nlm.nih.gov/pubmed/34833716
http://dx.doi.org/10.3390/s21227644
work_keys_str_mv AT maenhoutgertjan controlledmeasurementsetupforultrawidebanddielectricmodelingofmuscletissuein2045ctemperaturerange
AT markovictomislav controlledmeasurementsetupforultrawidebanddielectricmodelingofmuscletissuein2045ctemperaturerange
AT nauwelaersbart controlledmeasurementsetupforultrawidebanddielectricmodelingofmuscletissuein2045ctemperaturerange