Cargando…
Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range
In order to design electromagnetic applicators for diagnostic and therapeutic applications, an adequate dielectric tissue model is required. In addition, tissue temperature will heavily influence the dielectric properties and the dielectric model should, thus, be extended to incorporate this tempera...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617941/ https://www.ncbi.nlm.nih.gov/pubmed/34833716 http://dx.doi.org/10.3390/s21227644 |
_version_ | 1784604627927302144 |
---|---|
author | Maenhout, Gertjan Markovic, Tomislav Nauwelaers, Bart |
author_facet | Maenhout, Gertjan Markovic, Tomislav Nauwelaers, Bart |
author_sort | Maenhout, Gertjan |
collection | PubMed |
description | In order to design electromagnetic applicators for diagnostic and therapeutic applications, an adequate dielectric tissue model is required. In addition, tissue temperature will heavily influence the dielectric properties and the dielectric model should, thus, be extended to incorporate this temperature dependence. Thus, this work has a dual purpose. Given the influence of temperature, dehydration, and probe-to-tissue contact pressure on dielectric measurements, this work will initially present the first setup to actively control and monitor the temperature of the sample, the dehydration rate of the investigated sample, and the applied probe-to-tissue contact pressure. Secondly, this work measured the dielectric properties of porcine muscle in the 0.5–40 GHz frequency range for temperatures from 20 °C to 45 °C. Following measurements, a single-pole Cole–Cole model is presented, in which the five Cole–Cole parameters ([Formula: see text] , [Formula: see text] , [Formula: see text] , [Formula: see text] , and [Formula: see text]) are given by a first order polynomial as function of tissue temperature. The dielectric model closely agrees with the limited dielectric models known in literature for muscle tissue at 37 °C, which makes it suited for the design of in vivo applicators. Furthermore, the dielectric data at 41–45 °C is of great importance for the design of hyperthermia applicators. |
format | Online Article Text |
id | pubmed-8617941 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86179412021-11-27 Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range Maenhout, Gertjan Markovic, Tomislav Nauwelaers, Bart Sensors (Basel) Article In order to design electromagnetic applicators for diagnostic and therapeutic applications, an adequate dielectric tissue model is required. In addition, tissue temperature will heavily influence the dielectric properties and the dielectric model should, thus, be extended to incorporate this temperature dependence. Thus, this work has a dual purpose. Given the influence of temperature, dehydration, and probe-to-tissue contact pressure on dielectric measurements, this work will initially present the first setup to actively control and monitor the temperature of the sample, the dehydration rate of the investigated sample, and the applied probe-to-tissue contact pressure. Secondly, this work measured the dielectric properties of porcine muscle in the 0.5–40 GHz frequency range for temperatures from 20 °C to 45 °C. Following measurements, a single-pole Cole–Cole model is presented, in which the five Cole–Cole parameters ([Formula: see text] , [Formula: see text] , [Formula: see text] , [Formula: see text] , and [Formula: see text]) are given by a first order polynomial as function of tissue temperature. The dielectric model closely agrees with the limited dielectric models known in literature for muscle tissue at 37 °C, which makes it suited for the design of in vivo applicators. Furthermore, the dielectric data at 41–45 °C is of great importance for the design of hyperthermia applicators. MDPI 2021-11-17 /pmc/articles/PMC8617941/ /pubmed/34833716 http://dx.doi.org/10.3390/s21227644 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Maenhout, Gertjan Markovic, Tomislav Nauwelaers, Bart Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range |
title | Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range |
title_full | Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range |
title_fullStr | Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range |
title_full_unstemmed | Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range |
title_short | Controlled Measurement Setup for Ultra-Wideband Dielectric Modeling of Muscle Tissue in 20–45 °C Temperature Range |
title_sort | controlled measurement setup for ultra-wideband dielectric modeling of muscle tissue in 20–45 °c temperature range |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8617941/ https://www.ncbi.nlm.nih.gov/pubmed/34833716 http://dx.doi.org/10.3390/s21227644 |
work_keys_str_mv | AT maenhoutgertjan controlledmeasurementsetupforultrawidebanddielectricmodelingofmuscletissuein2045ctemperaturerange AT markovictomislav controlledmeasurementsetupforultrawidebanddielectricmodelingofmuscletissuein2045ctemperaturerange AT nauwelaersbart controlledmeasurementsetupforultrawidebanddielectricmodelingofmuscletissuein2045ctemperaturerange |