Cargando…

Sensitive Detection of Thiourea Hazardous Toxin with Sandwich-Type Nafion/CuO/ZnO Nanospikes/Glassy Carbon Composite Electrodes

In this research study, we developed a voltammetric electrochemical sensor probe with a copolymer Nafion (Sulfonated Tetrafluoroethylene-based Fluoro-polymer) decorated with hydrothermally prepared sandwich-type CuO/ZnO nanospikes (NSs) onto a glassy carbon electrode (GCE) for reliable thiourea (TU)...

Descripción completa

Detalles Bibliográficos
Autores principales: Rahman, Mohammed M., Alam, Md M., Alfaifi, Sulaiman Y. M., Asiri, Abdullah M., Ali, Meser M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8618075/
https://www.ncbi.nlm.nih.gov/pubmed/34833297
http://dx.doi.org/10.3390/polym13223998
_version_ 1784604660422672384
author Rahman, Mohammed M.
Alam, Md M.
Alfaifi, Sulaiman Y. M.
Asiri, Abdullah M.
Ali, Meser M.
author_facet Rahman, Mohammed M.
Alam, Md M.
Alfaifi, Sulaiman Y. M.
Asiri, Abdullah M.
Ali, Meser M.
author_sort Rahman, Mohammed M.
collection PubMed
description In this research study, we developed a voltammetric electrochemical sensor probe with a copolymer Nafion (Sulfonated Tetrafluoroethylene-based Fluoro-polymer) decorated with hydrothermally prepared sandwich-type CuO/ZnO nanospikes (NSs) onto a glassy carbon electrode (GCE) for reliable thiourea (TU) detection. The detailed characterizations in terms of structural morphology, binding energy, elemental compositions, grain size and crystallinity for synthesized NSs were performed by field emission scanning electron microscopy (FESEM), X-ray photoelectron spectroscopy (XPS), energy-dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD) analysis, respectively. The differential pulse voltammetric (DPV) analysis for TU showed good linearity at current-versus-TU concentration on the calibration plot in the 0.15~1.20 mM range, which is defined as a dynamic detection range (LDR) of TU in a phosphate buffer solution. Considering the slope of LDR over the GCE-coated NSs surface area (0.0316 cm(2)), the TU sensor sensitivity (0.4122 µA µM(−1) cm(−2)) was obtained. Besides this, the low limit (LOD) for TU detection was calculated and found to be 23.03 ± 1.15 µM. The fabricated Nafion/CuO/ZnO NSs/GCE sensor probe was created as a reliable sensor based on reproducibility, interference effect, stability and response time. Real bio-samples were investigated and the results confirm the anticipated reliability of the TU sensor probe. Thus, this is a noble way to develop enzyme-free electrochemical sensors that could be an alternative approach for the detection of chemicals in the field of enzyme-free biosensor development technology.
format Online
Article
Text
id pubmed-8618075
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86180752021-11-27 Sensitive Detection of Thiourea Hazardous Toxin with Sandwich-Type Nafion/CuO/ZnO Nanospikes/Glassy Carbon Composite Electrodes Rahman, Mohammed M. Alam, Md M. Alfaifi, Sulaiman Y. M. Asiri, Abdullah M. Ali, Meser M. Polymers (Basel) Article In this research study, we developed a voltammetric electrochemical sensor probe with a copolymer Nafion (Sulfonated Tetrafluoroethylene-based Fluoro-polymer) decorated with hydrothermally prepared sandwich-type CuO/ZnO nanospikes (NSs) onto a glassy carbon electrode (GCE) for reliable thiourea (TU) detection. The detailed characterizations in terms of structural morphology, binding energy, elemental compositions, grain size and crystallinity for synthesized NSs were performed by field emission scanning electron microscopy (FESEM), X-ray photoelectron spectroscopy (XPS), energy-dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD) analysis, respectively. The differential pulse voltammetric (DPV) analysis for TU showed good linearity at current-versus-TU concentration on the calibration plot in the 0.15~1.20 mM range, which is defined as a dynamic detection range (LDR) of TU in a phosphate buffer solution. Considering the slope of LDR over the GCE-coated NSs surface area (0.0316 cm(2)), the TU sensor sensitivity (0.4122 µA µM(−1) cm(−2)) was obtained. Besides this, the low limit (LOD) for TU detection was calculated and found to be 23.03 ± 1.15 µM. The fabricated Nafion/CuO/ZnO NSs/GCE sensor probe was created as a reliable sensor based on reproducibility, interference effect, stability and response time. Real bio-samples were investigated and the results confirm the anticipated reliability of the TU sensor probe. Thus, this is a noble way to develop enzyme-free electrochemical sensors that could be an alternative approach for the detection of chemicals in the field of enzyme-free biosensor development technology. MDPI 2021-11-19 /pmc/articles/PMC8618075/ /pubmed/34833297 http://dx.doi.org/10.3390/polym13223998 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Rahman, Mohammed M.
Alam, Md M.
Alfaifi, Sulaiman Y. M.
Asiri, Abdullah M.
Ali, Meser M.
Sensitive Detection of Thiourea Hazardous Toxin with Sandwich-Type Nafion/CuO/ZnO Nanospikes/Glassy Carbon Composite Electrodes
title Sensitive Detection of Thiourea Hazardous Toxin with Sandwich-Type Nafion/CuO/ZnO Nanospikes/Glassy Carbon Composite Electrodes
title_full Sensitive Detection of Thiourea Hazardous Toxin with Sandwich-Type Nafion/CuO/ZnO Nanospikes/Glassy Carbon Composite Electrodes
title_fullStr Sensitive Detection of Thiourea Hazardous Toxin with Sandwich-Type Nafion/CuO/ZnO Nanospikes/Glassy Carbon Composite Electrodes
title_full_unstemmed Sensitive Detection of Thiourea Hazardous Toxin with Sandwich-Type Nafion/CuO/ZnO Nanospikes/Glassy Carbon Composite Electrodes
title_short Sensitive Detection of Thiourea Hazardous Toxin with Sandwich-Type Nafion/CuO/ZnO Nanospikes/Glassy Carbon Composite Electrodes
title_sort sensitive detection of thiourea hazardous toxin with sandwich-type nafion/cuo/zno nanospikes/glassy carbon composite electrodes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8618075/
https://www.ncbi.nlm.nih.gov/pubmed/34833297
http://dx.doi.org/10.3390/polym13223998
work_keys_str_mv AT rahmanmohammedm sensitivedetectionofthioureahazardoustoxinwithsandwichtypenafioncuoznonanospikesglassycarboncompositeelectrodes
AT alammdm sensitivedetectionofthioureahazardoustoxinwithsandwichtypenafioncuoznonanospikesglassycarboncompositeelectrodes
AT alfaifisulaimanym sensitivedetectionofthioureahazardoustoxinwithsandwichtypenafioncuoznonanospikesglassycarboncompositeelectrodes
AT asiriabdullahm sensitivedetectionofthioureahazardoustoxinwithsandwichtypenafioncuoznonanospikesglassycarboncompositeelectrodes
AT alimeserm sensitivedetectionofthioureahazardoustoxinwithsandwichtypenafioncuoznonanospikesglassycarboncompositeelectrodes