Cargando…

Biomimetic Composite Coatings for Activation of Titanium Implant Surfaces: Methodological Approach and In Vivo Enhanced Osseointegration

Innovative nanomaterials are required for the coatings of titanium (Ti) implants to ensure the activation of Ti surfaces for improved osseointegration, enhanced bone fracture healing and bone regeneration. This paper presents a systematic investigation of biomimetic composite (BC) coatings on Ti imp...

Descripción completa

Detalles Bibliográficos
Autores principales: Oltean-Dan, Daniel, Dogaru, Gabriela-Bombonica, Jianu, Elena-Mihaela, Riga, Sorin, Tomoaia-Cotisel, Maria, Mocanu, Aurora, Barbu-Tudoran, Lucian, Tomoaia, Gheorghe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8618198/
https://www.ncbi.nlm.nih.gov/pubmed/34832764
http://dx.doi.org/10.3390/mi12111352
_version_ 1784604689936941056
author Oltean-Dan, Daniel
Dogaru, Gabriela-Bombonica
Jianu, Elena-Mihaela
Riga, Sorin
Tomoaia-Cotisel, Maria
Mocanu, Aurora
Barbu-Tudoran, Lucian
Tomoaia, Gheorghe
author_facet Oltean-Dan, Daniel
Dogaru, Gabriela-Bombonica
Jianu, Elena-Mihaela
Riga, Sorin
Tomoaia-Cotisel, Maria
Mocanu, Aurora
Barbu-Tudoran, Lucian
Tomoaia, Gheorghe
author_sort Oltean-Dan, Daniel
collection PubMed
description Innovative nanomaterials are required for the coatings of titanium (Ti) implants to ensure the activation of Ti surfaces for improved osseointegration, enhanced bone fracture healing and bone regeneration. This paper presents a systematic investigation of biomimetic composite (BC) coatings on Ti implant surfaces in a rat model of a diaphyseal femoral fracture. Methodological approaches of surface modification of the Ti implants via the usual joining methods (e.g., grit blasting and acid etching) and advanced physicochemical coating via a self-assembled dip-coating method were used. The biomimetic procedure used multi-substituted hydroxyapatite (ms-HAP) HAP-1.5 wt% Mg-0.2 wt% Zn-0.2 wt% Si nanoparticles (NPs), which were functionalized using collagen type 1 molecules (COL), resulting in ms-HAP/COL (core/shell) NPs that were embedded into a polylactic acid (PLA) matrix and finally covered with COL layers, obtaining the ms-HAP/COL@PLA/COL composite. To assess the osseointegration issue, first, the thickness, surface morphology and roughness of the BC coating on the Ti implants were determined using AFM and SEM. The BC-coated Ti implants and uncoated Ti implants were then used in Wistar albino rats with a diaphyseal femoral fracture, both in the absence and the presence of high-frequency pulsed electromagnetic shortwave (HF-PESW) stimulation. This study was performed using a bone marker serum concentration and histological and computer tomography (micro-CT) analysis at 2 and 8 weeks after surgical implantation. The implant osseointegration was evaluated through the bone–implant contact (BIC). The bone–implant interface was investigated using FE-SEM images and EDX spectra of the retrieved surgical implants at 8 weeks in the four animal groups. The obtained results showed significantly higher bone–implants contact and bone volume per tissue volume, as well as a greater amount of newly formed bone, in the BC-coated Ti implants than in the uncoated Ti implants. Direct bone–implant contact was also confirmed via histological examination. The results of this study confirmed that these biomimetic composite coatings on Ti implants were essential for a significant enhancement of osseointegration of BC-coated Ti implants and bone regeneration. This research provides a novel strategy for the treatment of bone fractures with possible orthopedic applications.
format Online
Article
Text
id pubmed-8618198
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86181982021-11-27 Biomimetic Composite Coatings for Activation of Titanium Implant Surfaces: Methodological Approach and In Vivo Enhanced Osseointegration Oltean-Dan, Daniel Dogaru, Gabriela-Bombonica Jianu, Elena-Mihaela Riga, Sorin Tomoaia-Cotisel, Maria Mocanu, Aurora Barbu-Tudoran, Lucian Tomoaia, Gheorghe Micromachines (Basel) Article Innovative nanomaterials are required for the coatings of titanium (Ti) implants to ensure the activation of Ti surfaces for improved osseointegration, enhanced bone fracture healing and bone regeneration. This paper presents a systematic investigation of biomimetic composite (BC) coatings on Ti implant surfaces in a rat model of a diaphyseal femoral fracture. Methodological approaches of surface modification of the Ti implants via the usual joining methods (e.g., grit blasting and acid etching) and advanced physicochemical coating via a self-assembled dip-coating method were used. The biomimetic procedure used multi-substituted hydroxyapatite (ms-HAP) HAP-1.5 wt% Mg-0.2 wt% Zn-0.2 wt% Si nanoparticles (NPs), which were functionalized using collagen type 1 molecules (COL), resulting in ms-HAP/COL (core/shell) NPs that were embedded into a polylactic acid (PLA) matrix and finally covered with COL layers, obtaining the ms-HAP/COL@PLA/COL composite. To assess the osseointegration issue, first, the thickness, surface morphology and roughness of the BC coating on the Ti implants were determined using AFM and SEM. The BC-coated Ti implants and uncoated Ti implants were then used in Wistar albino rats with a diaphyseal femoral fracture, both in the absence and the presence of high-frequency pulsed electromagnetic shortwave (HF-PESW) stimulation. This study was performed using a bone marker serum concentration and histological and computer tomography (micro-CT) analysis at 2 and 8 weeks after surgical implantation. The implant osseointegration was evaluated through the bone–implant contact (BIC). The bone–implant interface was investigated using FE-SEM images and EDX spectra of the retrieved surgical implants at 8 weeks in the four animal groups. The obtained results showed significantly higher bone–implants contact and bone volume per tissue volume, as well as a greater amount of newly formed bone, in the BC-coated Ti implants than in the uncoated Ti implants. Direct bone–implant contact was also confirmed via histological examination. The results of this study confirmed that these biomimetic composite coatings on Ti implants were essential for a significant enhancement of osseointegration of BC-coated Ti implants and bone regeneration. This research provides a novel strategy for the treatment of bone fractures with possible orthopedic applications. MDPI 2021-10-31 /pmc/articles/PMC8618198/ /pubmed/34832764 http://dx.doi.org/10.3390/mi12111352 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Oltean-Dan, Daniel
Dogaru, Gabriela-Bombonica
Jianu, Elena-Mihaela
Riga, Sorin
Tomoaia-Cotisel, Maria
Mocanu, Aurora
Barbu-Tudoran, Lucian
Tomoaia, Gheorghe
Biomimetic Composite Coatings for Activation of Titanium Implant Surfaces: Methodological Approach and In Vivo Enhanced Osseointegration
title Biomimetic Composite Coatings for Activation of Titanium Implant Surfaces: Methodological Approach and In Vivo Enhanced Osseointegration
title_full Biomimetic Composite Coatings for Activation of Titanium Implant Surfaces: Methodological Approach and In Vivo Enhanced Osseointegration
title_fullStr Biomimetic Composite Coatings for Activation of Titanium Implant Surfaces: Methodological Approach and In Vivo Enhanced Osseointegration
title_full_unstemmed Biomimetic Composite Coatings for Activation of Titanium Implant Surfaces: Methodological Approach and In Vivo Enhanced Osseointegration
title_short Biomimetic Composite Coatings for Activation of Titanium Implant Surfaces: Methodological Approach and In Vivo Enhanced Osseointegration
title_sort biomimetic composite coatings for activation of titanium implant surfaces: methodological approach and in vivo enhanced osseointegration
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8618198/
https://www.ncbi.nlm.nih.gov/pubmed/34832764
http://dx.doi.org/10.3390/mi12111352
work_keys_str_mv AT olteandandaniel biomimeticcompositecoatingsforactivationoftitaniumimplantsurfacesmethodologicalapproachandinvivoenhancedosseointegration
AT dogarugabrielabombonica biomimeticcompositecoatingsforactivationoftitaniumimplantsurfacesmethodologicalapproachandinvivoenhancedosseointegration
AT jianuelenamihaela biomimeticcompositecoatingsforactivationoftitaniumimplantsurfacesmethodologicalapproachandinvivoenhancedosseointegration
AT rigasorin biomimeticcompositecoatingsforactivationoftitaniumimplantsurfacesmethodologicalapproachandinvivoenhancedosseointegration
AT tomoaiacotiselmaria biomimeticcompositecoatingsforactivationoftitaniumimplantsurfacesmethodologicalapproachandinvivoenhancedosseointegration
AT mocanuaurora biomimeticcompositecoatingsforactivationoftitaniumimplantsurfacesmethodologicalapproachandinvivoenhancedosseointegration
AT barbutudoranlucian biomimeticcompositecoatingsforactivationoftitaniumimplantsurfacesmethodologicalapproachandinvivoenhancedosseointegration
AT tomoaiagheorghe biomimeticcompositecoatingsforactivationoftitaniumimplantsurfacesmethodologicalapproachandinvivoenhancedosseointegration