Cargando…

Analysis and Modification of Methods for Calculating Axial Load Capacity of High-Strength Steel-Reinforced Concrete Composite Columns

To investigate the applicability of the methods for calculating the bearing capacity of high-strength steel-reinforced concrete (SRC) composite columns according to specifications and the effect of confinement of stirrups and steel on the bearing capacity of SRC columns. The axial compression tests...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Jun, Duan, Yuxin, Wang, Yifan, Wang, Xinran, Liu, Qi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8618388/
https://www.ncbi.nlm.nih.gov/pubmed/34832262
http://dx.doi.org/10.3390/ma14226860
_version_ 1784604735469256704
author Wang, Jun
Duan, Yuxin
Wang, Yifan
Wang, Xinran
Liu, Qi
author_facet Wang, Jun
Duan, Yuxin
Wang, Yifan
Wang, Xinran
Liu, Qi
author_sort Wang, Jun
collection PubMed
description To investigate the applicability of the methods for calculating the bearing capacity of high-strength steel-reinforced concrete (SRC) composite columns according to specifications and the effect of confinement of stirrups and steel on the bearing capacity of SRC columns. The axial compression tests were conducted on 10 high-strength SRC columns and 4 ordinary SRC columns. The influences of the steel strength grade, the steel ratio, the types of stirrups and slenderness ratio on the bearing capacity of such members were examined. The analysis results indicate that using high-strength steel and improving the steel ratio can significantly enhance the bearing capacity of the SRC columns. When the slenderness ratio increases dramatically, the bearing capacity of the SRC columns plummets. As the confinement effect of the stirrups on the concrete improves, the utilization ratio of the high-strength steel in the SRC columns increases. Furthermore, the results calculated by AISC360-19(U.S.), EN1994-1-1-2004 (Europe), and JGJ138-2016(China) are too conservative compared with test results. Finally, a modified formula for calculating the bearing capacity of the SRC columns is proposed based on the confinement effect of the stirrups and steel on concrete. The results calculated by the modified formula and the finite element modeling results based on the confinement effect agree well with the test results.
format Online
Article
Text
id pubmed-8618388
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86183882021-11-27 Analysis and Modification of Methods for Calculating Axial Load Capacity of High-Strength Steel-Reinforced Concrete Composite Columns Wang, Jun Duan, Yuxin Wang, Yifan Wang, Xinran Liu, Qi Materials (Basel) Article To investigate the applicability of the methods for calculating the bearing capacity of high-strength steel-reinforced concrete (SRC) composite columns according to specifications and the effect of confinement of stirrups and steel on the bearing capacity of SRC columns. The axial compression tests were conducted on 10 high-strength SRC columns and 4 ordinary SRC columns. The influences of the steel strength grade, the steel ratio, the types of stirrups and slenderness ratio on the bearing capacity of such members were examined. The analysis results indicate that using high-strength steel and improving the steel ratio can significantly enhance the bearing capacity of the SRC columns. When the slenderness ratio increases dramatically, the bearing capacity of the SRC columns plummets. As the confinement effect of the stirrups on the concrete improves, the utilization ratio of the high-strength steel in the SRC columns increases. Furthermore, the results calculated by AISC360-19(U.S.), EN1994-1-1-2004 (Europe), and JGJ138-2016(China) are too conservative compared with test results. Finally, a modified formula for calculating the bearing capacity of the SRC columns is proposed based on the confinement effect of the stirrups and steel on concrete. The results calculated by the modified formula and the finite element modeling results based on the confinement effect agree well with the test results. MDPI 2021-11-14 /pmc/articles/PMC8618388/ /pubmed/34832262 http://dx.doi.org/10.3390/ma14226860 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Jun
Duan, Yuxin
Wang, Yifan
Wang, Xinran
Liu, Qi
Analysis and Modification of Methods for Calculating Axial Load Capacity of High-Strength Steel-Reinforced Concrete Composite Columns
title Analysis and Modification of Methods for Calculating Axial Load Capacity of High-Strength Steel-Reinforced Concrete Composite Columns
title_full Analysis and Modification of Methods for Calculating Axial Load Capacity of High-Strength Steel-Reinforced Concrete Composite Columns
title_fullStr Analysis and Modification of Methods for Calculating Axial Load Capacity of High-Strength Steel-Reinforced Concrete Composite Columns
title_full_unstemmed Analysis and Modification of Methods for Calculating Axial Load Capacity of High-Strength Steel-Reinforced Concrete Composite Columns
title_short Analysis and Modification of Methods for Calculating Axial Load Capacity of High-Strength Steel-Reinforced Concrete Composite Columns
title_sort analysis and modification of methods for calculating axial load capacity of high-strength steel-reinforced concrete composite columns
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8618388/
https://www.ncbi.nlm.nih.gov/pubmed/34832262
http://dx.doi.org/10.3390/ma14226860
work_keys_str_mv AT wangjun analysisandmodificationofmethodsforcalculatingaxialloadcapacityofhighstrengthsteelreinforcedconcretecompositecolumns
AT duanyuxin analysisandmodificationofmethodsforcalculatingaxialloadcapacityofhighstrengthsteelreinforcedconcretecompositecolumns
AT wangyifan analysisandmodificationofmethodsforcalculatingaxialloadcapacityofhighstrengthsteelreinforcedconcretecompositecolumns
AT wangxinran analysisandmodificationofmethodsforcalculatingaxialloadcapacityofhighstrengthsteelreinforcedconcretecompositecolumns
AT liuqi analysisandmodificationofmethodsforcalculatingaxialloadcapacityofhighstrengthsteelreinforcedconcretecompositecolumns