Cargando…

A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT

The purpose of this study was to analyze the effectiveness of newly developed dental dual-energy (DE) cone-beam computed tomography (CBCT) to compare both the voxel values in hard bone tissue of DE-CBCT and multidetector computed tomography (MDCT) images, collected in a clinical trial conducted at S...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Sungho, Lee, Sang Chul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8619558/
https://www.ncbi.nlm.nih.gov/pubmed/34833629
http://dx.doi.org/10.3390/s21227552
_version_ 1784605021918199808
author Chang, Sungho
Lee, Sang Chul
author_facet Chang, Sungho
Lee, Sang Chul
author_sort Chang, Sungho
collection PubMed
description The purpose of this study was to analyze the effectiveness of newly developed dental dual-energy (DE) cone-beam computed tomography (CBCT) to compare both the voxel values in hard bone tissue of DE-CBCT and multidetector computed tomography (MDCT) images, collected in a clinical trial conducted at Seoul National University Dental Hospital. A software implemented as a scripted module of a three-dimensional (3D) slicer was developed to register the volume data from the MDCT space to DE-CBCT, locate the same 3D regions of interest (ROIs) in each image space, and extract the statistics of the ROIs. The mean values were paired and used as representative values of the ROIs. A scatter plot with the line of equality and Bland–Altman (BA) plot of difference for a pair of measured means were used for statistical analysis. Of the ROI pairs, 96% were within ±15% from the identity line, and more than 95% of the measured ROI pairs were within the limits of agreement of the 95% confidence intervals (CIs), with the CI of the limits in BA plots. The newly developed dental DE-CBCT showed a level of voxel value accuracy similar to that of MDCT.
format Online
Article
Text
id pubmed-8619558
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86195582021-11-27 A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT Chang, Sungho Lee, Sang Chul Sensors (Basel) Article The purpose of this study was to analyze the effectiveness of newly developed dental dual-energy (DE) cone-beam computed tomography (CBCT) to compare both the voxel values in hard bone tissue of DE-CBCT and multidetector computed tomography (MDCT) images, collected in a clinical trial conducted at Seoul National University Dental Hospital. A software implemented as a scripted module of a three-dimensional (3D) slicer was developed to register the volume data from the MDCT space to DE-CBCT, locate the same 3D regions of interest (ROIs) in each image space, and extract the statistics of the ROIs. The mean values were paired and used as representative values of the ROIs. A scatter plot with the line of equality and Bland–Altman (BA) plot of difference for a pair of measured means were used for statistical analysis. Of the ROI pairs, 96% were within ±15% from the identity line, and more than 95% of the measured ROI pairs were within the limits of agreement of the 95% confidence intervals (CIs), with the CI of the limits in BA plots. The newly developed dental DE-CBCT showed a level of voxel value accuracy similar to that of MDCT. MDPI 2021-11-13 /pmc/articles/PMC8619558/ /pubmed/34833629 http://dx.doi.org/10.3390/s21227552 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chang, Sungho
Lee, Sang Chul
A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT
title A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT
title_full A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT
title_fullStr A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT
title_full_unstemmed A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT
title_short A Comparative Study on the Voxel Values in Alveolar Bones Acquired by MDCT and Newly Developed Dental Dual-Energy CBCT
title_sort comparative study on the voxel values in alveolar bones acquired by mdct and newly developed dental dual-energy cbct
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8619558/
https://www.ncbi.nlm.nih.gov/pubmed/34833629
http://dx.doi.org/10.3390/s21227552
work_keys_str_mv AT changsungho acomparativestudyonthevoxelvaluesinalveolarbonesacquiredbymdctandnewlydevelopeddentaldualenergycbct
AT leesangchul acomparativestudyonthevoxelvaluesinalveolarbonesacquiredbymdctandnewlydevelopeddentaldualenergycbct
AT changsungho comparativestudyonthevoxelvaluesinalveolarbonesacquiredbymdctandnewlydevelopeddentaldualenergycbct
AT leesangchul comparativestudyonthevoxelvaluesinalveolarbonesacquiredbymdctandnewlydevelopeddentaldualenergycbct