Cargando…
Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique
(1) Background: In polytrauma patients, femur fractures are usually stabilised by external fixation for damage control, later being treated with definitive plate or nail osteosynthesis. Screw/rod systems established in spinal surgery might be inserted for internal fixation, providing sufficient frac...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8620013/ https://www.ncbi.nlm.nih.gov/pubmed/34833130 http://dx.doi.org/10.3390/life11111254 |
_version_ | 1784605122666430464 |
---|---|
author | Layher, Frank Matziolis, Georg Kayhan, Leos N. Bungartz, Matthias Brinkmann, Olaf |
author_facet | Layher, Frank Matziolis, Georg Kayhan, Leos N. Bungartz, Matthias Brinkmann, Olaf |
author_sort | Layher, Frank |
collection | PubMed |
description | (1) Background: In polytrauma patients, femur fractures are usually stabilised by external fixation for damage control, later being treated with definitive plate or nail osteosynthesis. Screw/rod systems established in spinal surgery might be inserted for internal fixation, providing sufficient fracture stability that subsequent intervention is unnecessary. This was to be investigated biomechanically. (2) Methods: The unilaterally applied spinal internal fixator (IF) was subjected to load and deformation analysis on artificial femurs with 32-A3 fracture according to AO classification. Distance of screws to fracture and rod to cortical bone were analysed as parameters influenced surgically as stiffness and deformation of the treated fracture. In addition, the stability of another construct with a second screw/rod system was determined. The axial load in stance phase during walking was simulated. The results were compared against an established fixed-angle plate osteosynthesis (IP). (3) Results: There were no implant failures in the form of fractures, avulsions or deformations. All unilateral IF combinations were inferior to IP in terms of stability and stiffness. The bilateral construct with two screw/rod systems achieved biomechanical properties comparable to IP. 4) Conclusion: Biomechanically, a biplanar screw/rod system is suitable for definitive fracture stabilisation of the femur, despite a damage control approach. |
format | Online Article Text |
id | pubmed-8620013 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86200132021-11-27 Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique Layher, Frank Matziolis, Georg Kayhan, Leos N. Bungartz, Matthias Brinkmann, Olaf Life (Basel) Article (1) Background: In polytrauma patients, femur fractures are usually stabilised by external fixation for damage control, later being treated with definitive plate or nail osteosynthesis. Screw/rod systems established in spinal surgery might be inserted for internal fixation, providing sufficient fracture stability that subsequent intervention is unnecessary. This was to be investigated biomechanically. (2) Methods: The unilaterally applied spinal internal fixator (IF) was subjected to load and deformation analysis on artificial femurs with 32-A3 fracture according to AO classification. Distance of screws to fracture and rod to cortical bone were analysed as parameters influenced surgically as stiffness and deformation of the treated fracture. In addition, the stability of another construct with a second screw/rod system was determined. The axial load in stance phase during walking was simulated. The results were compared against an established fixed-angle plate osteosynthesis (IP). (3) Results: There were no implant failures in the form of fractures, avulsions or deformations. All unilateral IF combinations were inferior to IP in terms of stability and stiffness. The bilateral construct with two screw/rod systems achieved biomechanical properties comparable to IP. 4) Conclusion: Biomechanically, a biplanar screw/rod system is suitable for definitive fracture stabilisation of the femur, despite a damage control approach. MDPI 2021-11-17 /pmc/articles/PMC8620013/ /pubmed/34833130 http://dx.doi.org/10.3390/life11111254 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Layher, Frank Matziolis, Georg Kayhan, Leos N. Bungartz, Matthias Brinkmann, Olaf Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique |
title | Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique |
title_full | Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique |
title_fullStr | Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique |
title_full_unstemmed | Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique |
title_short | Minimally Invasive Internal Fixation of Femoral Shaft Fractures—A Biomechanical Study with a Disruptive Technique |
title_sort | minimally invasive internal fixation of femoral shaft fractures—a biomechanical study with a disruptive technique |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8620013/ https://www.ncbi.nlm.nih.gov/pubmed/34833130 http://dx.doi.org/10.3390/life11111254 |
work_keys_str_mv | AT layherfrank minimallyinvasiveinternalfixationoffemoralshaftfracturesabiomechanicalstudywithadisruptivetechnique AT matziolisgeorg minimallyinvasiveinternalfixationoffemoralshaftfracturesabiomechanicalstudywithadisruptivetechnique AT kayhanleosn minimallyinvasiveinternalfixationoffemoralshaftfracturesabiomechanicalstudywithadisruptivetechnique AT bungartzmatthias minimallyinvasiveinternalfixationoffemoralshaftfracturesabiomechanicalstudywithadisruptivetechnique AT brinkmannolaf minimallyinvasiveinternalfixationoffemoralshaftfracturesabiomechanicalstudywithadisruptivetechnique |