Cargando…

Micromachined Tactile Sensor Array for RTSA

This work presents a polymer-based tactile capacitive sensor capable of measuring joint reaction forces of reverse total shoulder arthroplasty (RTSA). The capacitive sensor contains a polydimethylsiloxane (PDMS) dielectric layer with an array of electrodes. The sensor was designed in such a way that...

Descripción completa

Detalles Bibliográficos
Autores principales: Leinauer, Elliott C., Kim, H. Mike, Kwon, Jae W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8620456/
https://www.ncbi.nlm.nih.gov/pubmed/34832841
http://dx.doi.org/10.3390/mi12111430
_version_ 1784605224471625728
author Leinauer, Elliott C.
Kim, H. Mike
Kwon, Jae W.
author_facet Leinauer, Elliott C.
Kim, H. Mike
Kwon, Jae W.
author_sort Leinauer, Elliott C.
collection PubMed
description This work presents a polymer-based tactile capacitive sensor capable of measuring joint reaction forces of reverse total shoulder arthroplasty (RTSA). The capacitive sensor contains a polydimethylsiloxane (PDMS) dielectric layer with an array of electrodes. The sensor was designed in such a way that four components of glenohumeral contact forces can be quantified to help ensure proper soft tissue tensioning during the procedure. Fabricated using soft lithography, the sensor has a loading time of approximately 400 ms when a 14.13 kPa load is applied and has a sensitivity of 1.24 × 10(−3) pF/kPa at a load of 1649 kPa. A replica RTSA prothesis was 3D printed, and the sensor was mounted inside the humeral cap. Four static right shoulder positions were tested, and the results provided an intuitive graphical description of the pressure distribution across four quadrants of the glenohumeral joint contact surface. It may help clinicians choose a right implant size and offset that best fit a patient’s anatomy and reduce postoperative biomechanical complications such as dislocation and stress fracture of the scapula.
format Online
Article
Text
id pubmed-8620456
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86204562021-11-27 Micromachined Tactile Sensor Array for RTSA Leinauer, Elliott C. Kim, H. Mike Kwon, Jae W. Micromachines (Basel) Article This work presents a polymer-based tactile capacitive sensor capable of measuring joint reaction forces of reverse total shoulder arthroplasty (RTSA). The capacitive sensor contains a polydimethylsiloxane (PDMS) dielectric layer with an array of electrodes. The sensor was designed in such a way that four components of glenohumeral contact forces can be quantified to help ensure proper soft tissue tensioning during the procedure. Fabricated using soft lithography, the sensor has a loading time of approximately 400 ms when a 14.13 kPa load is applied and has a sensitivity of 1.24 × 10(−3) pF/kPa at a load of 1649 kPa. A replica RTSA prothesis was 3D printed, and the sensor was mounted inside the humeral cap. Four static right shoulder positions were tested, and the results provided an intuitive graphical description of the pressure distribution across four quadrants of the glenohumeral joint contact surface. It may help clinicians choose a right implant size and offset that best fit a patient’s anatomy and reduce postoperative biomechanical complications such as dislocation and stress fracture of the scapula. MDPI 2021-11-21 /pmc/articles/PMC8620456/ /pubmed/34832841 http://dx.doi.org/10.3390/mi12111430 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Leinauer, Elliott C.
Kim, H. Mike
Kwon, Jae W.
Micromachined Tactile Sensor Array for RTSA
title Micromachined Tactile Sensor Array for RTSA
title_full Micromachined Tactile Sensor Array for RTSA
title_fullStr Micromachined Tactile Sensor Array for RTSA
title_full_unstemmed Micromachined Tactile Sensor Array for RTSA
title_short Micromachined Tactile Sensor Array for RTSA
title_sort micromachined tactile sensor array for rtsa
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8620456/
https://www.ncbi.nlm.nih.gov/pubmed/34832841
http://dx.doi.org/10.3390/mi12111430
work_keys_str_mv AT leinauerelliottc micromachinedtactilesensorarrayforrtsa
AT kimhmike micromachinedtactilesensorarrayforrtsa
AT kwonjaew micromachinedtactilesensorarrayforrtsa