Simply Fabricated Inexpensive Dual-Polymer-Coated Fabry-Perot Interferometer-Based Temperature Sensors with High Sensitivity
We designed simply fabricated, highly sensitive, and cost-effective dual-polymer-coated Fabry–Perot interferometer (DFPI)-based temperature sensors by employing thermosensitive polymers and non-thermosensitive polymers, as well as different two successive dip-coating techniques (stepwise dip coating...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8620928/ https://www.ncbi.nlm.nih.gov/pubmed/34833708 http://dx.doi.org/10.3390/s21227632 |
_version_ | 1784605335213834240 |
---|---|
author | Salunkhe, Tejaswi Tanaji Lee, Ho Kyung Choi, Hyung Wook Park, Sang Joon Kim, Il Tae |
author_facet | Salunkhe, Tejaswi Tanaji Lee, Ho Kyung Choi, Hyung Wook Park, Sang Joon Kim, Il Tae |
author_sort | Salunkhe, Tejaswi Tanaji |
collection | PubMed |
description | We designed simply fabricated, highly sensitive, and cost-effective dual-polymer-coated Fabry–Perot interferometer (DFPI)-based temperature sensors by employing thermosensitive polymers and non-thermosensitive polymers, as well as different two successive dip-coating techniques (stepwise dip coating and polymer mixture coating). Seven sensors were fabricated using different polymer combinations for performance optimization. The experiments demonstrated that the stepwise dip-coated dual thermosensitive polymer sensors exhibited the highest sensitivity (2142.5 pm °C(−1) for poly(methyl methacrylate)-polycarbonate (PMMA_PC) and 785.5 pm °C(−1) for poly(methyl methacrylate)- polystyrene (PMMA_PS)). Conversely, the polymer-mixture-coated sensors yielded low sensitivities (339.5 pm °C(−1) for the poly(methyl methacrylate)-polycarbonate mixture (PMMA_PC mixture) and 233.5 pm °C(−1) for the poly(methyl methacrylate)-polystyrene mixture (PMMA_PS mixture). Thus, the coating method, polymer selection, and thin air-bubble-free coating are crucial for high-sensitivity DFPI-based sensors. Furthermore, the DFPI-based sensors yielded stable readouts, based on three measurements. Our comprehensive results confirm the effectiveness, reproducibility, stability, fast response, feasibility, and accuracy of temperature measurements using the proposed sensors. The excellent performance and simplicity of our proposed sensors are promising for biomedical, biochemical, and physical applications. |
format | Online Article Text |
id | pubmed-8620928 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86209282021-11-27 Simply Fabricated Inexpensive Dual-Polymer-Coated Fabry-Perot Interferometer-Based Temperature Sensors with High Sensitivity Salunkhe, Tejaswi Tanaji Lee, Ho Kyung Choi, Hyung Wook Park, Sang Joon Kim, Il Tae Sensors (Basel) Article We designed simply fabricated, highly sensitive, and cost-effective dual-polymer-coated Fabry–Perot interferometer (DFPI)-based temperature sensors by employing thermosensitive polymers and non-thermosensitive polymers, as well as different two successive dip-coating techniques (stepwise dip coating and polymer mixture coating). Seven sensors were fabricated using different polymer combinations for performance optimization. The experiments demonstrated that the stepwise dip-coated dual thermosensitive polymer sensors exhibited the highest sensitivity (2142.5 pm °C(−1) for poly(methyl methacrylate)-polycarbonate (PMMA_PC) and 785.5 pm °C(−1) for poly(methyl methacrylate)- polystyrene (PMMA_PS)). Conversely, the polymer-mixture-coated sensors yielded low sensitivities (339.5 pm °C(−1) for the poly(methyl methacrylate)-polycarbonate mixture (PMMA_PC mixture) and 233.5 pm °C(−1) for the poly(methyl methacrylate)-polystyrene mixture (PMMA_PS mixture). Thus, the coating method, polymer selection, and thin air-bubble-free coating are crucial for high-sensitivity DFPI-based sensors. Furthermore, the DFPI-based sensors yielded stable readouts, based on three measurements. Our comprehensive results confirm the effectiveness, reproducibility, stability, fast response, feasibility, and accuracy of temperature measurements using the proposed sensors. The excellent performance and simplicity of our proposed sensors are promising for biomedical, biochemical, and physical applications. MDPI 2021-11-17 /pmc/articles/PMC8620928/ /pubmed/34833708 http://dx.doi.org/10.3390/s21227632 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Salunkhe, Tejaswi Tanaji Lee, Ho Kyung Choi, Hyung Wook Park, Sang Joon Kim, Il Tae Simply Fabricated Inexpensive Dual-Polymer-Coated Fabry-Perot Interferometer-Based Temperature Sensors with High Sensitivity |
title | Simply Fabricated Inexpensive Dual-Polymer-Coated Fabry-Perot Interferometer-Based Temperature Sensors with High Sensitivity |
title_full | Simply Fabricated Inexpensive Dual-Polymer-Coated Fabry-Perot Interferometer-Based Temperature Sensors with High Sensitivity |
title_fullStr | Simply Fabricated Inexpensive Dual-Polymer-Coated Fabry-Perot Interferometer-Based Temperature Sensors with High Sensitivity |
title_full_unstemmed | Simply Fabricated Inexpensive Dual-Polymer-Coated Fabry-Perot Interferometer-Based Temperature Sensors with High Sensitivity |
title_short | Simply Fabricated Inexpensive Dual-Polymer-Coated Fabry-Perot Interferometer-Based Temperature Sensors with High Sensitivity |
title_sort | simply fabricated inexpensive dual-polymer-coated fabry-perot interferometer-based temperature sensors with high sensitivity |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8620928/ https://www.ncbi.nlm.nih.gov/pubmed/34833708 http://dx.doi.org/10.3390/s21227632 |
work_keys_str_mv | AT salunkhetejaswitanaji simplyfabricatedinexpensivedualpolymercoatedfabryperotinterferometerbasedtemperaturesensorswithhighsensitivity AT leehokyung simplyfabricatedinexpensivedualpolymercoatedfabryperotinterferometerbasedtemperaturesensorswithhighsensitivity AT choihyungwook simplyfabricatedinexpensivedualpolymercoatedfabryperotinterferometerbasedtemperaturesensorswithhighsensitivity AT parksangjoon simplyfabricatedinexpensivedualpolymercoatedfabryperotinterferometerbasedtemperaturesensorswithhighsensitivity AT kimiltae simplyfabricatedinexpensivedualpolymercoatedfabryperotinterferometerbasedtemperaturesensorswithhighsensitivity |