Cargando…
Fabrication of High Performance PVDF Hollow Fiber Membrane Using Less Toxic Solvent at Different Additive Loading and Air Gap
Existing toxic solvents in the manufacturing of polymeric membranes have been raising concerns due to the risks of exposure to health and the environment. Furthermore, the lower tensile strength of the membrane renders these membranes unable to endure greater pressure during water treatment. To sust...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8622764/ https://www.ncbi.nlm.nih.gov/pubmed/34832072 http://dx.doi.org/10.3390/membranes11110843 |
_version_ | 1784605770541694976 |
---|---|
author | Zakria, Hazirah Syahirah Othman, Mohd Hafiz Dzarfan Kadir, Siti Hamimah Sheikh Abdul Kamaludin, Roziana Jilani, Asim Omar, Muhammad Firdaus Bakar, Suriani Abu Jaafar, Juhana Rahman, Mukhlis A. Abdullah, Huda Puteh, Mohd Hafiz Sinsamphanh, Oulavanh Ayub, Muhammad |
author_facet | Zakria, Hazirah Syahirah Othman, Mohd Hafiz Dzarfan Kadir, Siti Hamimah Sheikh Abdul Kamaludin, Roziana Jilani, Asim Omar, Muhammad Firdaus Bakar, Suriani Abu Jaafar, Juhana Rahman, Mukhlis A. Abdullah, Huda Puteh, Mohd Hafiz Sinsamphanh, Oulavanh Ayub, Muhammad |
author_sort | Zakria, Hazirah Syahirah |
collection | PubMed |
description | Existing toxic solvents in the manufacturing of polymeric membranes have been raising concerns due to the risks of exposure to health and the environment. Furthermore, the lower tensile strength of the membrane renders these membranes unable to endure greater pressure during water treatment. To sustain a healthier ecosystem, fabrication of polyvinylidene fluoride (PVDF) hollow fiber membrane using a less toxic solvent, triethyl phosphate (TEP), with a lower molecular weight polyethylene glycol (PEG 400) (0–3 wt.%) additive were experimentally demonstrated via a phase inversion-based spinning technique at various air gap (10, 20 and 30 cm). Membrane with 2 wt.% of PEG 400 exhibited the desired ultrafiltration asymmetric morphology, while 3 wt.% PEG 400 resulting microfiltration. The surface roughness, porosity, and water flux performance increased as the loading of PEG 400 increased. The mechanical properties and contact angle of the fabricated membrane were influenced by the air gap where 20 cm indicate 2.91 MPa and 84.72°, respectively, leading to a stronger tensile and hydrophilicity surface. Lower toxicity TEP as a solvent helped in increasing the tensile properties of the membrane as well as producing an eco-friendly membrane towards creating a sustainable environment. The comprehensive investigation in this study may present a novel composition for the robust structure of polymeric hollow fiber membrane that is suitable in membrane technology. |
format | Online Article Text |
id | pubmed-8622764 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86227642021-11-27 Fabrication of High Performance PVDF Hollow Fiber Membrane Using Less Toxic Solvent at Different Additive Loading and Air Gap Zakria, Hazirah Syahirah Othman, Mohd Hafiz Dzarfan Kadir, Siti Hamimah Sheikh Abdul Kamaludin, Roziana Jilani, Asim Omar, Muhammad Firdaus Bakar, Suriani Abu Jaafar, Juhana Rahman, Mukhlis A. Abdullah, Huda Puteh, Mohd Hafiz Sinsamphanh, Oulavanh Ayub, Muhammad Membranes (Basel) Article Existing toxic solvents in the manufacturing of polymeric membranes have been raising concerns due to the risks of exposure to health and the environment. Furthermore, the lower tensile strength of the membrane renders these membranes unable to endure greater pressure during water treatment. To sustain a healthier ecosystem, fabrication of polyvinylidene fluoride (PVDF) hollow fiber membrane using a less toxic solvent, triethyl phosphate (TEP), with a lower molecular weight polyethylene glycol (PEG 400) (0–3 wt.%) additive were experimentally demonstrated via a phase inversion-based spinning technique at various air gap (10, 20 and 30 cm). Membrane with 2 wt.% of PEG 400 exhibited the desired ultrafiltration asymmetric morphology, while 3 wt.% PEG 400 resulting microfiltration. The surface roughness, porosity, and water flux performance increased as the loading of PEG 400 increased. The mechanical properties and contact angle of the fabricated membrane were influenced by the air gap where 20 cm indicate 2.91 MPa and 84.72°, respectively, leading to a stronger tensile and hydrophilicity surface. Lower toxicity TEP as a solvent helped in increasing the tensile properties of the membrane as well as producing an eco-friendly membrane towards creating a sustainable environment. The comprehensive investigation in this study may present a novel composition for the robust structure of polymeric hollow fiber membrane that is suitable in membrane technology. MDPI 2021-10-29 /pmc/articles/PMC8622764/ /pubmed/34832072 http://dx.doi.org/10.3390/membranes11110843 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zakria, Hazirah Syahirah Othman, Mohd Hafiz Dzarfan Kadir, Siti Hamimah Sheikh Abdul Kamaludin, Roziana Jilani, Asim Omar, Muhammad Firdaus Bakar, Suriani Abu Jaafar, Juhana Rahman, Mukhlis A. Abdullah, Huda Puteh, Mohd Hafiz Sinsamphanh, Oulavanh Ayub, Muhammad Fabrication of High Performance PVDF Hollow Fiber Membrane Using Less Toxic Solvent at Different Additive Loading and Air Gap |
title | Fabrication of High Performance PVDF Hollow Fiber Membrane Using Less Toxic Solvent at Different Additive Loading and Air Gap |
title_full | Fabrication of High Performance PVDF Hollow Fiber Membrane Using Less Toxic Solvent at Different Additive Loading and Air Gap |
title_fullStr | Fabrication of High Performance PVDF Hollow Fiber Membrane Using Less Toxic Solvent at Different Additive Loading and Air Gap |
title_full_unstemmed | Fabrication of High Performance PVDF Hollow Fiber Membrane Using Less Toxic Solvent at Different Additive Loading and Air Gap |
title_short | Fabrication of High Performance PVDF Hollow Fiber Membrane Using Less Toxic Solvent at Different Additive Loading and Air Gap |
title_sort | fabrication of high performance pvdf hollow fiber membrane using less toxic solvent at different additive loading and air gap |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8622764/ https://www.ncbi.nlm.nih.gov/pubmed/34832072 http://dx.doi.org/10.3390/membranes11110843 |
work_keys_str_mv | AT zakriahazirahsyahirah fabricationofhighperformancepvdfhollowfibermembraneusinglesstoxicsolventatdifferentadditiveloadingandairgap AT othmanmohdhafizdzarfan fabricationofhighperformancepvdfhollowfibermembraneusinglesstoxicsolventatdifferentadditiveloadingandairgap AT kadirsitihamimahsheikhabdul fabricationofhighperformancepvdfhollowfibermembraneusinglesstoxicsolventatdifferentadditiveloadingandairgap AT kamaludinroziana fabricationofhighperformancepvdfhollowfibermembraneusinglesstoxicsolventatdifferentadditiveloadingandairgap AT jilaniasim fabricationofhighperformancepvdfhollowfibermembraneusinglesstoxicsolventatdifferentadditiveloadingandairgap AT omarmuhammadfirdaus fabricationofhighperformancepvdfhollowfibermembraneusinglesstoxicsolventatdifferentadditiveloadingandairgap AT bakarsurianiabu fabricationofhighperformancepvdfhollowfibermembraneusinglesstoxicsolventatdifferentadditiveloadingandairgap AT jaafarjuhana fabricationofhighperformancepvdfhollowfibermembraneusinglesstoxicsolventatdifferentadditiveloadingandairgap AT rahmanmukhlisa fabricationofhighperformancepvdfhollowfibermembraneusinglesstoxicsolventatdifferentadditiveloadingandairgap AT abdullahhuda fabricationofhighperformancepvdfhollowfibermembraneusinglesstoxicsolventatdifferentadditiveloadingandairgap AT putehmohdhafiz fabricationofhighperformancepvdfhollowfibermembraneusinglesstoxicsolventatdifferentadditiveloadingandairgap AT sinsamphanhoulavanh fabricationofhighperformancepvdfhollowfibermembraneusinglesstoxicsolventatdifferentadditiveloadingandairgap AT ayubmuhammad fabricationofhighperformancepvdfhollowfibermembraneusinglesstoxicsolventatdifferentadditiveloadingandairgap |