The Metrological Traceability, Performance and Precision of European Radon Calibration Facilities

An interlaboratory comparison for European radon calibration facilities was conducted to evaluate the establishment of a harmonized quality level for the activity concentration of radon in air and to demonstrate the performance of the facilities when calibrating measurement instruments for radon. Fi...

Descripción completa

Detalles Bibliográficos
Autores principales: Beck, Thomas R., Antohe, Andrei, Cardellini, Francesco, Cucoş, Alexandra, Fialova, Eliska, Grossi, Claudia, Hening, Kinga, Jensen, Jens, Kastratović, Dejan, Krivošík, Matej, Lobner, Patrick, Luca, Aurelian, Maringer, Franz Josef, Michielsen, Nathalie, Otahal, Petr P. S., Quindós, Luis, Rábago, Daniel, Sainz, Carlos, Szűcs, László, Teodorescu, Constantin, Tolinsson, Cathrin, Tugulan, Cornel Liviu, Turtiainen, Tuukka, Vargas, Arturo, Vosahlik, Josef, Vukoslavovic, Goran, Wiedner, Hannah, Wołoszczuk, Katarzyna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8623628/
https://www.ncbi.nlm.nih.gov/pubmed/34831904
http://dx.doi.org/10.3390/ijerph182212150
_version_ 1784605978150305792
author Beck, Thomas R.
Antohe, Andrei
Cardellini, Francesco
Cucoş, Alexandra
Fialova, Eliska
Grossi, Claudia
Hening, Kinga
Jensen, Jens
Kastratović, Dejan
Krivošík, Matej
Lobner, Patrick
Luca, Aurelian
Maringer, Franz Josef
Michielsen, Nathalie
Otahal, Petr P. S.
Quindós, Luis
Rábago, Daniel
Sainz, Carlos
Szűcs, László
Teodorescu, Constantin
Tolinsson, Cathrin
Tugulan, Cornel Liviu
Turtiainen, Tuukka
Vargas, Arturo
Vosahlik, Josef
Vukoslavovic, Goran
Wiedner, Hannah
Wołoszczuk, Katarzyna
author_facet Beck, Thomas R.
Antohe, Andrei
Cardellini, Francesco
Cucoş, Alexandra
Fialova, Eliska
Grossi, Claudia
Hening, Kinga
Jensen, Jens
Kastratović, Dejan
Krivošík, Matej
Lobner, Patrick
Luca, Aurelian
Maringer, Franz Josef
Michielsen, Nathalie
Otahal, Petr P. S.
Quindós, Luis
Rábago, Daniel
Sainz, Carlos
Szűcs, László
Teodorescu, Constantin
Tolinsson, Cathrin
Tugulan, Cornel Liviu
Turtiainen, Tuukka
Vargas, Arturo
Vosahlik, Josef
Vukoslavovic, Goran
Wiedner, Hannah
Wołoszczuk, Katarzyna
author_sort Beck, Thomas R.
collection PubMed
description An interlaboratory comparison for European radon calibration facilities was conducted to evaluate the establishment of a harmonized quality level for the activity concentration of radon in air and to demonstrate the performance of the facilities when calibrating measurement instruments for radon. Fifteen calibration facilities from 13 different European countries participated. They represented different levels in the metrological hierarchy: national metrology institutes and designated institutes, national authorities for radiation protection and participants from universities. The interlaboratory comparison was conducted by the German Federal Office for Radiation Protection (BfS) and took place from 2018 to 2020. Participants were requested to measure radon in atmospheres of their own facilities according to their own procedures and requirements for metrological traceability. A measurement device with suitable properties was used to determine the comparison values. The results of the comparison showed that the radon activity concentrations that were determined by European calibration facilities complying with metrological traceability requirements were consistent with each other and had common mean values. The deviations from these values were normally distributed. The range of variation of the common mean value was a measure of the degree of agreement between the participants. For exposures above 1000 Bq/m(3), the variation was about 4% for a level of confidence of approximately 95% [Formula: see text]. For lower exposure levels, the variation increased to about 6%.
format Online
Article
Text
id pubmed-8623628
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86236282021-11-27 The Metrological Traceability, Performance and Precision of European Radon Calibration Facilities Beck, Thomas R. Antohe, Andrei Cardellini, Francesco Cucoş, Alexandra Fialova, Eliska Grossi, Claudia Hening, Kinga Jensen, Jens Kastratović, Dejan Krivošík, Matej Lobner, Patrick Luca, Aurelian Maringer, Franz Josef Michielsen, Nathalie Otahal, Petr P. S. Quindós, Luis Rábago, Daniel Sainz, Carlos Szűcs, László Teodorescu, Constantin Tolinsson, Cathrin Tugulan, Cornel Liviu Turtiainen, Tuukka Vargas, Arturo Vosahlik, Josef Vukoslavovic, Goran Wiedner, Hannah Wołoszczuk, Katarzyna Int J Environ Res Public Health Article An interlaboratory comparison for European radon calibration facilities was conducted to evaluate the establishment of a harmonized quality level for the activity concentration of radon in air and to demonstrate the performance of the facilities when calibrating measurement instruments for radon. Fifteen calibration facilities from 13 different European countries participated. They represented different levels in the metrological hierarchy: national metrology institutes and designated institutes, national authorities for radiation protection and participants from universities. The interlaboratory comparison was conducted by the German Federal Office for Radiation Protection (BfS) and took place from 2018 to 2020. Participants were requested to measure radon in atmospheres of their own facilities according to their own procedures and requirements for metrological traceability. A measurement device with suitable properties was used to determine the comparison values. The results of the comparison showed that the radon activity concentrations that were determined by European calibration facilities complying with metrological traceability requirements were consistent with each other and had common mean values. The deviations from these values were normally distributed. The range of variation of the common mean value was a measure of the degree of agreement between the participants. For exposures above 1000 Bq/m(3), the variation was about 4% for a level of confidence of approximately 95% [Formula: see text]. For lower exposure levels, the variation increased to about 6%. MDPI 2021-11-19 /pmc/articles/PMC8623628/ /pubmed/34831904 http://dx.doi.org/10.3390/ijerph182212150 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Beck, Thomas R.
Antohe, Andrei
Cardellini, Francesco
Cucoş, Alexandra
Fialova, Eliska
Grossi, Claudia
Hening, Kinga
Jensen, Jens
Kastratović, Dejan
Krivošík, Matej
Lobner, Patrick
Luca, Aurelian
Maringer, Franz Josef
Michielsen, Nathalie
Otahal, Petr P. S.
Quindós, Luis
Rábago, Daniel
Sainz, Carlos
Szűcs, László
Teodorescu, Constantin
Tolinsson, Cathrin
Tugulan, Cornel Liviu
Turtiainen, Tuukka
Vargas, Arturo
Vosahlik, Josef
Vukoslavovic, Goran
Wiedner, Hannah
Wołoszczuk, Katarzyna
The Metrological Traceability, Performance and Precision of European Radon Calibration Facilities
title The Metrological Traceability, Performance and Precision of European Radon Calibration Facilities
title_full The Metrological Traceability, Performance and Precision of European Radon Calibration Facilities
title_fullStr The Metrological Traceability, Performance and Precision of European Radon Calibration Facilities
title_full_unstemmed The Metrological Traceability, Performance and Precision of European Radon Calibration Facilities
title_short The Metrological Traceability, Performance and Precision of European Radon Calibration Facilities
title_sort metrological traceability, performance and precision of european radon calibration facilities
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8623628/
https://www.ncbi.nlm.nih.gov/pubmed/34831904
http://dx.doi.org/10.3390/ijerph182212150
work_keys_str_mv AT beckthomasr themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT antoheandrei themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT cardellinifrancesco themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT cucosalexandra themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT fialovaeliska themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT grossiclaudia themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT heningkinga themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT jensenjens themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT kastratovicdejan themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT krivosikmatej themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT lobnerpatrick themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT lucaaurelian themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT maringerfranzjosef themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT michielsennathalie themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT otahalpetrps themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT quindosluis themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT rabagodaniel themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT sainzcarlos themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT szucslaszlo themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT teodorescuconstantin themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT tolinssoncathrin themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT tugulancornelliviu themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT turtiainentuukka themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT vargasarturo themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT vosahlikjosef themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT vukoslavovicgoran themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT wiednerhannah themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT wołoszczukkatarzyna themetrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT beckthomasr metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT antoheandrei metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT cardellinifrancesco metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT cucosalexandra metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT fialovaeliska metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT grossiclaudia metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT heningkinga metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT jensenjens metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT kastratovicdejan metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT krivosikmatej metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT lobnerpatrick metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT lucaaurelian metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT maringerfranzjosef metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT michielsennathalie metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT otahalpetrps metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT quindosluis metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT rabagodaniel metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT sainzcarlos metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT szucslaszlo metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT teodorescuconstantin metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT tolinssoncathrin metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT tugulancornelliviu metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT turtiainentuukka metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT vargasarturo metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT vosahlikjosef metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT vukoslavovicgoran metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT wiednerhannah metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities
AT wołoszczukkatarzyna metrologicaltraceabilityperformanceandprecisionofeuropeanradoncalibrationfacilities