Prediction of Membrane Failure in a Water Purification Plant Using Nonhomogeneous Poisson Process Models

The prediction of membrane failure in full-scale water purification plants is an important but difficult task. Although previous studies employed accelerated laboratory-scale tests of membrane failure, it is not possible to reproduce the complex operational conditions of full-scale plants. Therefore...

Descripción completa

Detalles Bibliográficos
Autores principales: Hashimoto, Takashi, Takizawa, Satoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8624650/
https://www.ncbi.nlm.nih.gov/pubmed/34832028
http://dx.doi.org/10.3390/membranes11110800
_version_ 1784606226571591680
author Hashimoto, Takashi
Takizawa, Satoshi
author_facet Hashimoto, Takashi
Takizawa, Satoshi
author_sort Hashimoto, Takashi
collection PubMed
description The prediction of membrane failure in full-scale water purification plants is an important but difficult task. Although previous studies employed accelerated laboratory-scale tests of membrane failure, it is not possible to reproduce the complex operational conditions of full-scale plants. Therefore, we aimed to develop prediction models of membrane failure using actual membrane failure data. Because membrane filtration systems are repairable systems, nonhomogeneous Poisson process (NHPP) models, i.e., power law and log-linear models, were employed; the model parameters were estimated using the membrane failure data from a full-scale plant operated for 13 years. Both models were able to predict cumulative failures for forthcoming years; nonetheless, the power law model showed higher stability and narrower confidence intervals than the log-linear model. By integrating two membrane replacement criteria, namely deterioration of filtrate water quality and reduction of membrane permeability, it was possible to predict the time to replace all the membranes on a water purification plant. Finally, the NHPP models coupled with a nonparametric bootstrap method provided a method to select membrane modules for earlier replacement than others. Although the criteria for membrane replacement may vary among membrane filtration plants, the NHPP models presented in this study could be applied to any other plant with membrane failure data.
format Online
Article
Text
id pubmed-8624650
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86246502021-11-27 Prediction of Membrane Failure in a Water Purification Plant Using Nonhomogeneous Poisson Process Models Hashimoto, Takashi Takizawa, Satoshi Membranes (Basel) Article The prediction of membrane failure in full-scale water purification plants is an important but difficult task. Although previous studies employed accelerated laboratory-scale tests of membrane failure, it is not possible to reproduce the complex operational conditions of full-scale plants. Therefore, we aimed to develop prediction models of membrane failure using actual membrane failure data. Because membrane filtration systems are repairable systems, nonhomogeneous Poisson process (NHPP) models, i.e., power law and log-linear models, were employed; the model parameters were estimated using the membrane failure data from a full-scale plant operated for 13 years. Both models were able to predict cumulative failures for forthcoming years; nonetheless, the power law model showed higher stability and narrower confidence intervals than the log-linear model. By integrating two membrane replacement criteria, namely deterioration of filtrate water quality and reduction of membrane permeability, it was possible to predict the time to replace all the membranes on a water purification plant. Finally, the NHPP models coupled with a nonparametric bootstrap method provided a method to select membrane modules for earlier replacement than others. Although the criteria for membrane replacement may vary among membrane filtration plants, the NHPP models presented in this study could be applied to any other plant with membrane failure data. MDPI 2021-10-20 /pmc/articles/PMC8624650/ /pubmed/34832028 http://dx.doi.org/10.3390/membranes11110800 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hashimoto, Takashi
Takizawa, Satoshi
Prediction of Membrane Failure in a Water Purification Plant Using Nonhomogeneous Poisson Process Models
title Prediction of Membrane Failure in a Water Purification Plant Using Nonhomogeneous Poisson Process Models
title_full Prediction of Membrane Failure in a Water Purification Plant Using Nonhomogeneous Poisson Process Models
title_fullStr Prediction of Membrane Failure in a Water Purification Plant Using Nonhomogeneous Poisson Process Models
title_full_unstemmed Prediction of Membrane Failure in a Water Purification Plant Using Nonhomogeneous Poisson Process Models
title_short Prediction of Membrane Failure in a Water Purification Plant Using Nonhomogeneous Poisson Process Models
title_sort prediction of membrane failure in a water purification plant using nonhomogeneous poisson process models
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8624650/
https://www.ncbi.nlm.nih.gov/pubmed/34832028
http://dx.doi.org/10.3390/membranes11110800
work_keys_str_mv AT hashimototakashi predictionofmembranefailureinawaterpurificationplantusingnonhomogeneouspoissonprocessmodels
AT takizawasatoshi predictionofmembranefailureinawaterpurificationplantusingnonhomogeneouspoissonprocessmodels