Cargando…
Inter- and Intraobserver Repeatability of Myocardial Flow Reserve Values Determined with SPECT Study Using a Discovery NM530c Camera and Corridor 4DM Software
Background: Myocardial blood flow (MBF) and flow reserve (MFR) examination, especially useful in the diagnosis of multivessel coronary artery disease (CAD), can be assessed with a cadmium-zinc-telluride (CZT) SPECT gamma camera, as an alternative to the expensive and less available PET. However, stu...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8624690/ https://www.ncbi.nlm.nih.gov/pubmed/34834516 http://dx.doi.org/10.3390/jpm11111164 |
_version_ | 1784606236073787392 |
---|---|
author | Cichocki, Paweł Błaszczyk, Michał Cygulska, Kamila Filipczak, Krzysztof Adamczewski, Zbigniew Kuśmierek, Jacek Lipiec, Piotr Kasprzak, Jarosław Damian Płachcińska, Anna |
author_facet | Cichocki, Paweł Błaszczyk, Michał Cygulska, Kamila Filipczak, Krzysztof Adamczewski, Zbigniew Kuśmierek, Jacek Lipiec, Piotr Kasprzak, Jarosław Damian Płachcińska, Anna |
author_sort | Cichocki, Paweł |
collection | PubMed |
description | Background: Myocardial blood flow (MBF) and flow reserve (MFR) examination, especially useful in the diagnosis of multivessel coronary artery disease (CAD), can be assessed with a cadmium-zinc-telluride (CZT) SPECT gamma camera, as an alternative to the expensive and less available PET. However, study processing is not free from subjective factors. Therefore, this paper aims to evaluate intra- and interobserver repeatability of MBF and MFR values obtained by the same operator and two independent operators. Methods: This study included 57 adult patients. MBF and MFR were assessed using a Discovery NM530c camera in a two-day, rest/dipyridamople protocol, using (99m)Tc-MIBI. Data were processed using Corridor4DM software, twice by one operator and once by another operator. Results: The repeatability of the assessed values was quite good in the whole myocardium, LAD and LCX vascular territories, but was poor in the RCA territory. Conclusions: The poor repeatability of MBF and MFR in RCA vascular territory can be explained by poor automatic orientation of the heart axis during post-processing and a so-called “cardiac creep” phenomenon. Better automatic heart orientation and introduction of automatic motion correction is likely to drastically improve this repeatability. In the present state of the software, PET is better for patients requiring assessment of MFR in the RCA territory. |
format | Online Article Text |
id | pubmed-8624690 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86246902021-11-27 Inter- and Intraobserver Repeatability of Myocardial Flow Reserve Values Determined with SPECT Study Using a Discovery NM530c Camera and Corridor 4DM Software Cichocki, Paweł Błaszczyk, Michał Cygulska, Kamila Filipczak, Krzysztof Adamczewski, Zbigniew Kuśmierek, Jacek Lipiec, Piotr Kasprzak, Jarosław Damian Płachcińska, Anna J Pers Med Article Background: Myocardial blood flow (MBF) and flow reserve (MFR) examination, especially useful in the diagnosis of multivessel coronary artery disease (CAD), can be assessed with a cadmium-zinc-telluride (CZT) SPECT gamma camera, as an alternative to the expensive and less available PET. However, study processing is not free from subjective factors. Therefore, this paper aims to evaluate intra- and interobserver repeatability of MBF and MFR values obtained by the same operator and two independent operators. Methods: This study included 57 adult patients. MBF and MFR were assessed using a Discovery NM530c camera in a two-day, rest/dipyridamople protocol, using (99m)Tc-MIBI. Data were processed using Corridor4DM software, twice by one operator and once by another operator. Results: The repeatability of the assessed values was quite good in the whole myocardium, LAD and LCX vascular territories, but was poor in the RCA territory. Conclusions: The poor repeatability of MBF and MFR in RCA vascular territory can be explained by poor automatic orientation of the heart axis during post-processing and a so-called “cardiac creep” phenomenon. Better automatic heart orientation and introduction of automatic motion correction is likely to drastically improve this repeatability. In the present state of the software, PET is better for patients requiring assessment of MFR in the RCA territory. MDPI 2021-11-09 /pmc/articles/PMC8624690/ /pubmed/34834516 http://dx.doi.org/10.3390/jpm11111164 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Cichocki, Paweł Błaszczyk, Michał Cygulska, Kamila Filipczak, Krzysztof Adamczewski, Zbigniew Kuśmierek, Jacek Lipiec, Piotr Kasprzak, Jarosław Damian Płachcińska, Anna Inter- and Intraobserver Repeatability of Myocardial Flow Reserve Values Determined with SPECT Study Using a Discovery NM530c Camera and Corridor 4DM Software |
title | Inter- and Intraobserver Repeatability of Myocardial Flow Reserve Values Determined with SPECT Study Using a Discovery NM530c Camera and Corridor 4DM Software |
title_full | Inter- and Intraobserver Repeatability of Myocardial Flow Reserve Values Determined with SPECT Study Using a Discovery NM530c Camera and Corridor 4DM Software |
title_fullStr | Inter- and Intraobserver Repeatability of Myocardial Flow Reserve Values Determined with SPECT Study Using a Discovery NM530c Camera and Corridor 4DM Software |
title_full_unstemmed | Inter- and Intraobserver Repeatability of Myocardial Flow Reserve Values Determined with SPECT Study Using a Discovery NM530c Camera and Corridor 4DM Software |
title_short | Inter- and Intraobserver Repeatability of Myocardial Flow Reserve Values Determined with SPECT Study Using a Discovery NM530c Camera and Corridor 4DM Software |
title_sort | inter- and intraobserver repeatability of myocardial flow reserve values determined with spect study using a discovery nm530c camera and corridor 4dm software |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8624690/ https://www.ncbi.nlm.nih.gov/pubmed/34834516 http://dx.doi.org/10.3390/jpm11111164 |
work_keys_str_mv | AT cichockipaweł interandintraobserverrepeatabilityofmyocardialflowreservevaluesdeterminedwithspectstudyusingadiscoverynm530ccameraandcorridor4dmsoftware AT błaszczykmichał interandintraobserverrepeatabilityofmyocardialflowreservevaluesdeterminedwithspectstudyusingadiscoverynm530ccameraandcorridor4dmsoftware AT cygulskakamila interandintraobserverrepeatabilityofmyocardialflowreservevaluesdeterminedwithspectstudyusingadiscoverynm530ccameraandcorridor4dmsoftware AT filipczakkrzysztof interandintraobserverrepeatabilityofmyocardialflowreservevaluesdeterminedwithspectstudyusingadiscoverynm530ccameraandcorridor4dmsoftware AT adamczewskizbigniew interandintraobserverrepeatabilityofmyocardialflowreservevaluesdeterminedwithspectstudyusingadiscoverynm530ccameraandcorridor4dmsoftware AT kusmierekjacek interandintraobserverrepeatabilityofmyocardialflowreservevaluesdeterminedwithspectstudyusingadiscoverynm530ccameraandcorridor4dmsoftware AT lipiecpiotr interandintraobserverrepeatabilityofmyocardialflowreservevaluesdeterminedwithspectstudyusingadiscoverynm530ccameraandcorridor4dmsoftware AT kasprzakjarosławdamian interandintraobserverrepeatabilityofmyocardialflowreservevaluesdeterminedwithspectstudyusingadiscoverynm530ccameraandcorridor4dmsoftware AT płachcinskaanna interandintraobserverrepeatabilityofmyocardialflowreservevaluesdeterminedwithspectstudyusingadiscoverynm530ccameraandcorridor4dmsoftware |