Cargando…

Evaluation of Gamma Radiation Properties of Four Types of Surgical Stainless Steel in the Energy Range of 17.50–25.29 keV

In this study, the gamma radiation properties of four types of surgical-grade stainless steel (304, 304L, 316 and 316L) were investigated. The effective atomic number Z [Formula: see text] , effective electron density N [Formula: see text] and half-value layer (HVL) of four types of surgical-grade s...

Descripción completa

Detalles Bibliográficos
Autores principales: Marashdeh, Mohammad, Al-Hamarneh, Ibrahim F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8624695/
https://www.ncbi.nlm.nih.gov/pubmed/34832275
http://dx.doi.org/10.3390/ma14226873
_version_ 1784606237261824000
author Marashdeh, Mohammad
Al-Hamarneh, Ibrahim F.
author_facet Marashdeh, Mohammad
Al-Hamarneh, Ibrahim F.
author_sort Marashdeh, Mohammad
collection PubMed
description In this study, the gamma radiation properties of four types of surgical-grade stainless steel (304, 304L, 316 and 316L) were investigated. The effective atomic number Z [Formula: see text] , effective electron density N [Formula: see text] and half-value layer (HVL) of four types of surgical-grade stainless steel were determined via the mass attenuation coefficient [Formula: see text]. The [Formula: see text] coefficients were determined experimentally using an X-ray fluorescence (XRF) technique and theoretically via the WinXCOM program. The K [Formula: see text] of XRF photons in the energy range between 17.50 and 25.29 keV was used from pure metal plates of molybdenum (Mo), palladium (Pd), silver (Ag) and tin (Sn). A comparison between the experimental and theoretical values of [Formula: see text] revealed that the experimental values were lower than the theoretical calculations. The relative differences between the theoretical and experimental values were found to decrease with increasing photon energy. The lowest percentage difference between the experimental and theoretical values of [Formula: see text] was between −6.17% and −9.76% and was obtained at a photon energy of 25.29 keV. Sample 316L showed the highest value of [Formula: see text] at the energies 21.20, 22.19 and 25.29 keV. In addition, the measured results of Z [Formula: see text] and N [Formula: see text] for all samples behaved similarly in the given energy range and were found to be in good agreement with the calculations. The equivalent atomic number (Z [Formula: see text]) of the investigated stainless-steel samples was calculated using the interpolation method to compare the samples at the same source energy. The 316L stainless steel had higher values of [Formula: see text] , Z [Formula: see text] and Z [Formula: see text] and lower values of HVL compared with the other samples. Therefore, it is concluded that the 316L sample is more effective in absorbing gamma radiation.
format Online
Article
Text
id pubmed-8624695
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86246952021-11-27 Evaluation of Gamma Radiation Properties of Four Types of Surgical Stainless Steel in the Energy Range of 17.50–25.29 keV Marashdeh, Mohammad Al-Hamarneh, Ibrahim F. Materials (Basel) Article In this study, the gamma radiation properties of four types of surgical-grade stainless steel (304, 304L, 316 and 316L) were investigated. The effective atomic number Z [Formula: see text] , effective electron density N [Formula: see text] and half-value layer (HVL) of four types of surgical-grade stainless steel were determined via the mass attenuation coefficient [Formula: see text]. The [Formula: see text] coefficients were determined experimentally using an X-ray fluorescence (XRF) technique and theoretically via the WinXCOM program. The K [Formula: see text] of XRF photons in the energy range between 17.50 and 25.29 keV was used from pure metal plates of molybdenum (Mo), palladium (Pd), silver (Ag) and tin (Sn). A comparison between the experimental and theoretical values of [Formula: see text] revealed that the experimental values were lower than the theoretical calculations. The relative differences between the theoretical and experimental values were found to decrease with increasing photon energy. The lowest percentage difference between the experimental and theoretical values of [Formula: see text] was between −6.17% and −9.76% and was obtained at a photon energy of 25.29 keV. Sample 316L showed the highest value of [Formula: see text] at the energies 21.20, 22.19 and 25.29 keV. In addition, the measured results of Z [Formula: see text] and N [Formula: see text] for all samples behaved similarly in the given energy range and were found to be in good agreement with the calculations. The equivalent atomic number (Z [Formula: see text]) of the investigated stainless-steel samples was calculated using the interpolation method to compare the samples at the same source energy. The 316L stainless steel had higher values of [Formula: see text] , Z [Formula: see text] and Z [Formula: see text] and lower values of HVL compared with the other samples. Therefore, it is concluded that the 316L sample is more effective in absorbing gamma radiation. MDPI 2021-11-15 /pmc/articles/PMC8624695/ /pubmed/34832275 http://dx.doi.org/10.3390/ma14226873 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Marashdeh, Mohammad
Al-Hamarneh, Ibrahim F.
Evaluation of Gamma Radiation Properties of Four Types of Surgical Stainless Steel in the Energy Range of 17.50–25.29 keV
title Evaluation of Gamma Radiation Properties of Four Types of Surgical Stainless Steel in the Energy Range of 17.50–25.29 keV
title_full Evaluation of Gamma Radiation Properties of Four Types of Surgical Stainless Steel in the Energy Range of 17.50–25.29 keV
title_fullStr Evaluation of Gamma Radiation Properties of Four Types of Surgical Stainless Steel in the Energy Range of 17.50–25.29 keV
title_full_unstemmed Evaluation of Gamma Radiation Properties of Four Types of Surgical Stainless Steel in the Energy Range of 17.50–25.29 keV
title_short Evaluation of Gamma Radiation Properties of Four Types of Surgical Stainless Steel in the Energy Range of 17.50–25.29 keV
title_sort evaluation of gamma radiation properties of four types of surgical stainless steel in the energy range of 17.50–25.29 kev
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8624695/
https://www.ncbi.nlm.nih.gov/pubmed/34832275
http://dx.doi.org/10.3390/ma14226873
work_keys_str_mv AT marashdehmohammad evaluationofgammaradiationpropertiesoffourtypesofsurgicalstainlesssteelintheenergyrangeof17502529kev
AT alhamarnehibrahimf evaluationofgammaradiationpropertiesoffourtypesofsurgicalstainlesssteelintheenergyrangeof17502529kev