Cargando…
To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes
ECMO is the most frequently used mechanical support for patients suffering from low cardiac output syndrome. Combining IABP with ECMO is believed to increase coronary artery blood flow, decrease high afterload, and restore systemic pulsatile flow conditions. This study evaluates that combined effect...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8624867/ https://www.ncbi.nlm.nih.gov/pubmed/34830619 http://dx.doi.org/10.3390/jcm10225333 |
_version_ | 1784606279081132032 |
---|---|
author | Reymond, Philippe Bendjelid, Karim Giraud, Raphaël Richard, Gérald Murith, Nicolas Cikirikcioglu, Mustafa Huber, Christoph |
author_facet | Reymond, Philippe Bendjelid, Karim Giraud, Raphaël Richard, Gérald Murith, Nicolas Cikirikcioglu, Mustafa Huber, Christoph |
author_sort | Reymond, Philippe |
collection | PubMed |
description | ECMO is the most frequently used mechanical support for patients suffering from low cardiac output syndrome. Combining IABP with ECMO is believed to increase coronary artery blood flow, decrease high afterload, and restore systemic pulsatile flow conditions. This study evaluates that combined effect on coronary artery flow during various load conditions using an in vitro circuit. In doing so, different clinical scenarios were simulated, such as normal cardiac output and moderate-to-severe heart failure. In the heart failure scenarios, we used peripheral ECMO support to compensate for the lowered cardiac output value and reach a default normal value. The increase in coronary blood flow using the combined IABP-ECMO setup was more noticeable in low heart rate conditions. At baseline, intermediate and severe LV failure levels, adding IABP increased coronary mean flow by 16%, 7.5%, and 3.4% (HR 60 bpm) and by 6%, 4.5%, and 2.5% (HR 100 bpm) respectively. Based on our in vitro study results, combining ECMO and IABP in a heart failure setup further improves coronary blood flow. This effect was more pronounced at a lower heart rate and decreased with heart failure, which might positively impact recovery from cardiac failure. |
format | Online Article Text |
id | pubmed-8624867 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-86248672021-11-27 To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes Reymond, Philippe Bendjelid, Karim Giraud, Raphaël Richard, Gérald Murith, Nicolas Cikirikcioglu, Mustafa Huber, Christoph J Clin Med Article ECMO is the most frequently used mechanical support for patients suffering from low cardiac output syndrome. Combining IABP with ECMO is believed to increase coronary artery blood flow, decrease high afterload, and restore systemic pulsatile flow conditions. This study evaluates that combined effect on coronary artery flow during various load conditions using an in vitro circuit. In doing so, different clinical scenarios were simulated, such as normal cardiac output and moderate-to-severe heart failure. In the heart failure scenarios, we used peripheral ECMO support to compensate for the lowered cardiac output value and reach a default normal value. The increase in coronary blood flow using the combined IABP-ECMO setup was more noticeable in low heart rate conditions. At baseline, intermediate and severe LV failure levels, adding IABP increased coronary mean flow by 16%, 7.5%, and 3.4% (HR 60 bpm) and by 6%, 4.5%, and 2.5% (HR 100 bpm) respectively. Based on our in vitro study results, combining ECMO and IABP in a heart failure setup further improves coronary blood flow. This effect was more pronounced at a lower heart rate and decreased with heart failure, which might positively impact recovery from cardiac failure. MDPI 2021-11-16 /pmc/articles/PMC8624867/ /pubmed/34830619 http://dx.doi.org/10.3390/jcm10225333 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Reymond, Philippe Bendjelid, Karim Giraud, Raphaël Richard, Gérald Murith, Nicolas Cikirikcioglu, Mustafa Huber, Christoph To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes |
title | To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes |
title_full | To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes |
title_fullStr | To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes |
title_full_unstemmed | To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes |
title_short | To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes |
title_sort | to balloon or not to balloon? the effects of an intra-aortic balloon-pump on coronary artery flow during extracorporeal circulation simulating normal and low cardiac output syndromes |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8624867/ https://www.ncbi.nlm.nih.gov/pubmed/34830619 http://dx.doi.org/10.3390/jcm10225333 |
work_keys_str_mv | AT reymondphilippe toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes AT bendjelidkarim toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes AT giraudraphael toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes AT richardgerald toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes AT murithnicolas toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes AT cikirikcioglumustafa toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes AT huberchristoph toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes |