Cargando…

To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes

ECMO is the most frequently used mechanical support for patients suffering from low cardiac output syndrome. Combining IABP with ECMO is believed to increase coronary artery blood flow, decrease high afterload, and restore systemic pulsatile flow conditions. This study evaluates that combined effect...

Descripción completa

Detalles Bibliográficos
Autores principales: Reymond, Philippe, Bendjelid, Karim, Giraud, Raphaël, Richard, Gérald, Murith, Nicolas, Cikirikcioglu, Mustafa, Huber, Christoph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8624867/
https://www.ncbi.nlm.nih.gov/pubmed/34830619
http://dx.doi.org/10.3390/jcm10225333
_version_ 1784606279081132032
author Reymond, Philippe
Bendjelid, Karim
Giraud, Raphaël
Richard, Gérald
Murith, Nicolas
Cikirikcioglu, Mustafa
Huber, Christoph
author_facet Reymond, Philippe
Bendjelid, Karim
Giraud, Raphaël
Richard, Gérald
Murith, Nicolas
Cikirikcioglu, Mustafa
Huber, Christoph
author_sort Reymond, Philippe
collection PubMed
description ECMO is the most frequently used mechanical support for patients suffering from low cardiac output syndrome. Combining IABP with ECMO is believed to increase coronary artery blood flow, decrease high afterload, and restore systemic pulsatile flow conditions. This study evaluates that combined effect on coronary artery flow during various load conditions using an in vitro circuit. In doing so, different clinical scenarios were simulated, such as normal cardiac output and moderate-to-severe heart failure. In the heart failure scenarios, we used peripheral ECMO support to compensate for the lowered cardiac output value and reach a default normal value. The increase in coronary blood flow using the combined IABP-ECMO setup was more noticeable in low heart rate conditions. At baseline, intermediate and severe LV failure levels, adding IABP increased coronary mean flow by 16%, 7.5%, and 3.4% (HR 60 bpm) and by 6%, 4.5%, and 2.5% (HR 100 bpm) respectively. Based on our in vitro study results, combining ECMO and IABP in a heart failure setup further improves coronary blood flow. This effect was more pronounced at a lower heart rate and decreased with heart failure, which might positively impact recovery from cardiac failure.
format Online
Article
Text
id pubmed-8624867
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86248672021-11-27 To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes Reymond, Philippe Bendjelid, Karim Giraud, Raphaël Richard, Gérald Murith, Nicolas Cikirikcioglu, Mustafa Huber, Christoph J Clin Med Article ECMO is the most frequently used mechanical support for patients suffering from low cardiac output syndrome. Combining IABP with ECMO is believed to increase coronary artery blood flow, decrease high afterload, and restore systemic pulsatile flow conditions. This study evaluates that combined effect on coronary artery flow during various load conditions using an in vitro circuit. In doing so, different clinical scenarios were simulated, such as normal cardiac output and moderate-to-severe heart failure. In the heart failure scenarios, we used peripheral ECMO support to compensate for the lowered cardiac output value and reach a default normal value. The increase in coronary blood flow using the combined IABP-ECMO setup was more noticeable in low heart rate conditions. At baseline, intermediate and severe LV failure levels, adding IABP increased coronary mean flow by 16%, 7.5%, and 3.4% (HR 60 bpm) and by 6%, 4.5%, and 2.5% (HR 100 bpm) respectively. Based on our in vitro study results, combining ECMO and IABP in a heart failure setup further improves coronary blood flow. This effect was more pronounced at a lower heart rate and decreased with heart failure, which might positively impact recovery from cardiac failure. MDPI 2021-11-16 /pmc/articles/PMC8624867/ /pubmed/34830619 http://dx.doi.org/10.3390/jcm10225333 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Reymond, Philippe
Bendjelid, Karim
Giraud, Raphaël
Richard, Gérald
Murith, Nicolas
Cikirikcioglu, Mustafa
Huber, Christoph
To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes
title To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes
title_full To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes
title_fullStr To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes
title_full_unstemmed To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes
title_short To Balloon or Not to Balloon? The Effects of an Intra-Aortic Balloon-Pump on Coronary Artery Flow during Extracorporeal Circulation Simulating Normal and Low Cardiac Output Syndromes
title_sort to balloon or not to balloon? the effects of an intra-aortic balloon-pump on coronary artery flow during extracorporeal circulation simulating normal and low cardiac output syndromes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8624867/
https://www.ncbi.nlm.nih.gov/pubmed/34830619
http://dx.doi.org/10.3390/jcm10225333
work_keys_str_mv AT reymondphilippe toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes
AT bendjelidkarim toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes
AT giraudraphael toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes
AT richardgerald toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes
AT murithnicolas toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes
AT cikirikcioglumustafa toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes
AT huberchristoph toballoonornottoballoontheeffectsofanintraaorticballoonpumponcoronaryarteryflowduringextracorporealcirculationsimulatingnormalandlowcardiacoutputsyndromes