Cargando…

Proximal Femoral Nail versus Proximal Femoral Nail Antirotation: Functional and Radiological Outcome in Intertrochanteric Fractures of Femur

Introduction Newer implant designs such as Proximal Femoral Nail (PFN) and Proximal Femoral Nail Antirotation (PFN-A) have shown promising results in the treatment of intertrochanteric fractures. Despite the availability of various implants for the treatment of these fractures, there is no common co...

Descripción completa

Detalles Bibliográficos
Autor principal: Singh, Siddhartha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8626865/
https://www.ncbi.nlm.nih.gov/pubmed/34868750
http://dx.doi.org/10.7759/cureus.19093
_version_ 1784606741214789632
author Singh, Siddhartha
author_facet Singh, Siddhartha
author_sort Singh, Siddhartha
collection PubMed
description Introduction Newer implant designs such as Proximal Femoral Nail (PFN) and Proximal Femoral Nail Antirotation (PFN-A) have shown promising results in the treatment of intertrochanteric fractures. Despite the availability of various implants for the treatment of these fractures, there is no common consensus as to which implant would be ideal. Therefore, there is a need for further clinical trials to establish the biomechanical and functional outcome superiority of implants such as PFN and PFN-A, especially among osteoporotic patients. Aim To compare the functional and radiological outcomes in intertrochanteric patients treated with PFN and PFN-A. Methodology A total of 152 intertrochanteric fracture patients were included in this retrospective study, 94 in the PFN group and 58 in the PFN-A group. The postoperative radiological outcome was assessed and compared using parameters such as tip-apex distance (TAD), Cleveland index, neck-shaft angle, and type of reduction. Operative time for the procedure, pre and postoperative hemoglobin levels were recorded and compared. Fracture union rates were compared at six weeks and six months. Functional outcome was compared between the two groups at follow-up period of 6 months using Harris Hip Score (HHS) and pre and postoperative Parker Palmer Mobility Score (PPS). Complication rates were compared between the two groups. Also, osteoporotic patients were evaluated using the same parameters. Results The radiological parameters were similar in both groups. There was a shorter operative time and better hemoglobin levels after surgery in the PFN-A group. The complication rate in the PFN group was 7.4% when compared to the PFN-A group which was just 1.7%. The functional outcome based on HHS and PPS was alike in the two groups. In osteoporotic patients randomized based on Singh’s index, better union rates were observed in the PFN-A group and a higher complication rate was seen in the PFN group. Conclusion Cephalomedullary nailing using PFN-A is superior to PFN in terms of a lesser procedure time, minimal blood loss, and fewer complications even among osteoporotic patients. The radiological specifications such as neck-shaft angle post-surgery, reduction type, TAD, and Cleveland index is of paramount importance which is established in this study.
format Online
Article
Text
id pubmed-8626865
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-86268652021-12-03 Proximal Femoral Nail versus Proximal Femoral Nail Antirotation: Functional and Radiological Outcome in Intertrochanteric Fractures of Femur Singh, Siddhartha Cureus Orthopedics Introduction Newer implant designs such as Proximal Femoral Nail (PFN) and Proximal Femoral Nail Antirotation (PFN-A) have shown promising results in the treatment of intertrochanteric fractures. Despite the availability of various implants for the treatment of these fractures, there is no common consensus as to which implant would be ideal. Therefore, there is a need for further clinical trials to establish the biomechanical and functional outcome superiority of implants such as PFN and PFN-A, especially among osteoporotic patients. Aim To compare the functional and radiological outcomes in intertrochanteric patients treated with PFN and PFN-A. Methodology A total of 152 intertrochanteric fracture patients were included in this retrospective study, 94 in the PFN group and 58 in the PFN-A group. The postoperative radiological outcome was assessed and compared using parameters such as tip-apex distance (TAD), Cleveland index, neck-shaft angle, and type of reduction. Operative time for the procedure, pre and postoperative hemoglobin levels were recorded and compared. Fracture union rates were compared at six weeks and six months. Functional outcome was compared between the two groups at follow-up period of 6 months using Harris Hip Score (HHS) and pre and postoperative Parker Palmer Mobility Score (PPS). Complication rates were compared between the two groups. Also, osteoporotic patients were evaluated using the same parameters. Results The radiological parameters were similar in both groups. There was a shorter operative time and better hemoglobin levels after surgery in the PFN-A group. The complication rate in the PFN group was 7.4% when compared to the PFN-A group which was just 1.7%. The functional outcome based on HHS and PPS was alike in the two groups. In osteoporotic patients randomized based on Singh’s index, better union rates were observed in the PFN-A group and a higher complication rate was seen in the PFN group. Conclusion Cephalomedullary nailing using PFN-A is superior to PFN in terms of a lesser procedure time, minimal blood loss, and fewer complications even among osteoporotic patients. The radiological specifications such as neck-shaft angle post-surgery, reduction type, TAD, and Cleveland index is of paramount importance which is established in this study. Cureus 2021-10-28 /pmc/articles/PMC8626865/ /pubmed/34868750 http://dx.doi.org/10.7759/cureus.19093 Text en Copyright © 2021, Singh et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopedics
Singh, Siddhartha
Proximal Femoral Nail versus Proximal Femoral Nail Antirotation: Functional and Radiological Outcome in Intertrochanteric Fractures of Femur
title Proximal Femoral Nail versus Proximal Femoral Nail Antirotation: Functional and Radiological Outcome in Intertrochanteric Fractures of Femur
title_full Proximal Femoral Nail versus Proximal Femoral Nail Antirotation: Functional and Radiological Outcome in Intertrochanteric Fractures of Femur
title_fullStr Proximal Femoral Nail versus Proximal Femoral Nail Antirotation: Functional and Radiological Outcome in Intertrochanteric Fractures of Femur
title_full_unstemmed Proximal Femoral Nail versus Proximal Femoral Nail Antirotation: Functional and Radiological Outcome in Intertrochanteric Fractures of Femur
title_short Proximal Femoral Nail versus Proximal Femoral Nail Antirotation: Functional and Radiological Outcome in Intertrochanteric Fractures of Femur
title_sort proximal femoral nail versus proximal femoral nail antirotation: functional and radiological outcome in intertrochanteric fractures of femur
topic Orthopedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8626865/
https://www.ncbi.nlm.nih.gov/pubmed/34868750
http://dx.doi.org/10.7759/cureus.19093
work_keys_str_mv AT singhsiddhartha proximalfemoralnailversusproximalfemoralnailantirotationfunctionalandradiologicaloutcomeinintertrochantericfracturesoffemur