Cargando…
Digital analysis of external fixation area of proximal humerus fractures in elderly patients
INTRODUCTION: The purpose is based on anatomical basis, combined with three-dimensional measurement, to guide the clinical repositioning of proximal humeral fractures, select the appropriate pin entry point and angle, and simulate surgery. METHODS: 11 fresh cadaveric specimens were collected, the di...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8626931/ https://www.ncbi.nlm.nih.gov/pubmed/34836534 http://dx.doi.org/10.1186/s12891-021-04826-0 |
_version_ | 1784606754526461952 |
---|---|
author | Xing, Baorui Zhang, Yadi Hou, Xiuxiu Li, Yunmei Li, Guoliang Han, Guangpu |
author_facet | Xing, Baorui Zhang, Yadi Hou, Xiuxiu Li, Yunmei Li, Guoliang Han, Guangpu |
author_sort | Xing, Baorui |
collection | PubMed |
description | INTRODUCTION: The purpose is based on anatomical basis, combined with three-dimensional measurement, to guide the clinical repositioning of proximal humeral fractures, select the appropriate pin entry point and angle, and simulate surgery. METHODS: 11 fresh cadaveric specimens were collected, the distance of the marked points around the shoulder joint was measured anatomically, and the vertical distance between the inferior border of the acromion and the superior border of the axillary nerve, the vertical distance between the apex of the humeral head and the superior border of the axillary nerve, the vertical distance between the inferior border of the acromion and the superior border of the anterior rotator humeral artery, and the vertical distance between the apex of the humeral head and the superior border of the anterior rotator humeral artery were marked on the 3D model based on the anatomical data to find the relative safety zone for pin placement. RESULTS: Contralateral data can be used to guide the repositioning and fixation of that side of the proximal humerus fracture, and uniform data cannot be used between male and female patients. For lateral pining, the distance of the inferior border of the acromion from the axillary nerve (5.90 ± 0.43) cm, range (5.3-6.9) cm, was selected for pining along the medial axis of the humeral head, close to the medial cervical cortex, and the pining angle was measured in the coronal plane (42.84 ± 2.45)°, range (37.02° ~ 46.31°), and in the sagittal plane (28.24 ± 2.25)°, range (19.22° ~ 28.51°). The pin was advanced laterally in front of the same level of the lateral approach point to form a cross-fixed support with the lateral pin, and the pin angle was measured in the coronal plane (36.14 ± 1.75)°, range (30.32° ~ 39.61°), and in the sagittal plane (28.64 ± 1.37)°, range (22.82° ~ 32.11°). Two pins were taken at the greater humeral tuberosity for fixation, with the proximal pin at an angle (159.26 ± 1.98) to the coronal surface of the humeral stem, range (155.79° ~ 165.08°), and the sagittal angle (161.76 ± 2.15)°, with the pin end between the superior surface of the humeral talus and the inferior surface of the humeral talus. The distal needle of the greater humeral tuberosity was parallel to the proximal approach trajectory, and the needle end was on the inferior surface of the humeral talus. CONCLUSION: Based on the anatomical data, we can accurately identify the corresponding bony structures of the proximal humerus and mark the location of the pin on the 3D model for pin placement, which is simple and practical to meet the relevant individual parameters. |
format | Online Article Text |
id | pubmed-8626931 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-86269312021-11-29 Digital analysis of external fixation area of proximal humerus fractures in elderly patients Xing, Baorui Zhang, Yadi Hou, Xiuxiu Li, Yunmei Li, Guoliang Han, Guangpu BMC Musculoskelet Disord Research INTRODUCTION: The purpose is based on anatomical basis, combined with three-dimensional measurement, to guide the clinical repositioning of proximal humeral fractures, select the appropriate pin entry point and angle, and simulate surgery. METHODS: 11 fresh cadaveric specimens were collected, the distance of the marked points around the shoulder joint was measured anatomically, and the vertical distance between the inferior border of the acromion and the superior border of the axillary nerve, the vertical distance between the apex of the humeral head and the superior border of the axillary nerve, the vertical distance between the inferior border of the acromion and the superior border of the anterior rotator humeral artery, and the vertical distance between the apex of the humeral head and the superior border of the anterior rotator humeral artery were marked on the 3D model based on the anatomical data to find the relative safety zone for pin placement. RESULTS: Contralateral data can be used to guide the repositioning and fixation of that side of the proximal humerus fracture, and uniform data cannot be used between male and female patients. For lateral pining, the distance of the inferior border of the acromion from the axillary nerve (5.90 ± 0.43) cm, range (5.3-6.9) cm, was selected for pining along the medial axis of the humeral head, close to the medial cervical cortex, and the pining angle was measured in the coronal plane (42.84 ± 2.45)°, range (37.02° ~ 46.31°), and in the sagittal plane (28.24 ± 2.25)°, range (19.22° ~ 28.51°). The pin was advanced laterally in front of the same level of the lateral approach point to form a cross-fixed support with the lateral pin, and the pin angle was measured in the coronal plane (36.14 ± 1.75)°, range (30.32° ~ 39.61°), and in the sagittal plane (28.64 ± 1.37)°, range (22.82° ~ 32.11°). Two pins were taken at the greater humeral tuberosity for fixation, with the proximal pin at an angle (159.26 ± 1.98) to the coronal surface of the humeral stem, range (155.79° ~ 165.08°), and the sagittal angle (161.76 ± 2.15)°, with the pin end between the superior surface of the humeral talus and the inferior surface of the humeral talus. The distal needle of the greater humeral tuberosity was parallel to the proximal approach trajectory, and the needle end was on the inferior surface of the humeral talus. CONCLUSION: Based on the anatomical data, we can accurately identify the corresponding bony structures of the proximal humerus and mark the location of the pin on the 3D model for pin placement, which is simple and practical to meet the relevant individual parameters. BioMed Central 2021-11-26 /pmc/articles/PMC8626931/ /pubmed/34836534 http://dx.doi.org/10.1186/s12891-021-04826-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Xing, Baorui Zhang, Yadi Hou, Xiuxiu Li, Yunmei Li, Guoliang Han, Guangpu Digital analysis of external fixation area of proximal humerus fractures in elderly patients |
title | Digital analysis of external fixation area of proximal humerus fractures in elderly patients |
title_full | Digital analysis of external fixation area of proximal humerus fractures in elderly patients |
title_fullStr | Digital analysis of external fixation area of proximal humerus fractures in elderly patients |
title_full_unstemmed | Digital analysis of external fixation area of proximal humerus fractures in elderly patients |
title_short | Digital analysis of external fixation area of proximal humerus fractures in elderly patients |
title_sort | digital analysis of external fixation area of proximal humerus fractures in elderly patients |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8626931/ https://www.ncbi.nlm.nih.gov/pubmed/34836534 http://dx.doi.org/10.1186/s12891-021-04826-0 |
work_keys_str_mv | AT xingbaorui digitalanalysisofexternalfixationareaofproximalhumerusfracturesinelderlypatients AT zhangyadi digitalanalysisofexternalfixationareaofproximalhumerusfracturesinelderlypatients AT houxiuxiu digitalanalysisofexternalfixationareaofproximalhumerusfracturesinelderlypatients AT liyunmei digitalanalysisofexternalfixationareaofproximalhumerusfracturesinelderlypatients AT liguoliang digitalanalysisofexternalfixationareaofproximalhumerusfracturesinelderlypatients AT hanguangpu digitalanalysisofexternalfixationareaofproximalhumerusfracturesinelderlypatients |