Cargando…
Diagnostic Accuracy of Nipple Discharge Fluid Cytology: A Meta-Analysis and Systematic Review of the Literature
BACKGROUND: Nipple discharge is the third most frequent complaint of women attending rapid diagnostic breast clinics. Nipple smear cytology remains the single most used diagnostic method for investigating fluid content. This study aimed to conduct a systematic review and meta-analysis of the diagnos...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8627297/ https://www.ncbi.nlm.nih.gov/pubmed/34839426 http://dx.doi.org/10.1245/s10434-021-11070-2 |
_version_ | 1784606824727576576 |
---|---|
author | Jiwa, Natasha Kumar, Swathica Gandhewar, Rishikesh Chauhan, Hemali Nagarajan, Vikneswaran Wright, Corrina Hadjiminas, Dimitri Takats, Zoltan Ashrafian, Hutan Leff, Daniel Richard |
author_facet | Jiwa, Natasha Kumar, Swathica Gandhewar, Rishikesh Chauhan, Hemali Nagarajan, Vikneswaran Wright, Corrina Hadjiminas, Dimitri Takats, Zoltan Ashrafian, Hutan Leff, Daniel Richard |
author_sort | Jiwa, Natasha |
collection | PubMed |
description | BACKGROUND: Nipple discharge is the third most frequent complaint of women attending rapid diagnostic breast clinics. Nipple smear cytology remains the single most used diagnostic method for investigating fluid content. This study aimed to conduct a systematic review and meta-analysis of the diagnostic accuracy of nipple discharge fluid assessment. METHODS: The study incorporated searches for studies interrogating the diagnostic data of nipple discharge fluid cytology compared with the histopathology gold standard. Data from studies published from 1956 to 2019 were analyzed. The analysis included 8648 cytology samples of women with a presenting complaint of nipple discharge. Both hierarchical and bivariate models for diagnostic meta-analysis were used to attain overall pooled sensitivity and specificity. RESULTS: Of 837 studies retrieved, 45 fulfilled the criteria for inclusion. The diagnostic accuracy of the meta-analysis examining nipple discharge fluid had a sensitivity of 75 % (95 % confidence interval [CI], 0.74–0.77) and a specificity of 87 % (95 % CI, 0.86–0.87) for benign breast disease. For breast cancer, it had a sensitivity of 62 % (95 % CI, 0.53–0.71) and a specificity 71 % (95 % CI, 0.57–0.81). Furthermore, patients presenting with blood-stained discharge yielded an overall malignancy rate of 58 % (95 % CI, 0.54–0.60) with a positive predictive value (PPV) of 27 % (95 % CI, 0.17–0.36). CONCLUSIONS: Pooled data from studies encompassing nipple discharge fluid assessment suggest that nipple smear cytology is of limited diagnostic accuracy. The authors recommend that a tailored approach to diagnosis be required given the variable sensitivities of currently available tests. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1245/s10434-021-11070-2. |
format | Online Article Text |
id | pubmed-8627297 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-86272972021-11-29 Diagnostic Accuracy of Nipple Discharge Fluid Cytology: A Meta-Analysis and Systematic Review of the Literature Jiwa, Natasha Kumar, Swathica Gandhewar, Rishikesh Chauhan, Hemali Nagarajan, Vikneswaran Wright, Corrina Hadjiminas, Dimitri Takats, Zoltan Ashrafian, Hutan Leff, Daniel Richard Ann Surg Oncol Breast Oncology BACKGROUND: Nipple discharge is the third most frequent complaint of women attending rapid diagnostic breast clinics. Nipple smear cytology remains the single most used diagnostic method for investigating fluid content. This study aimed to conduct a systematic review and meta-analysis of the diagnostic accuracy of nipple discharge fluid assessment. METHODS: The study incorporated searches for studies interrogating the diagnostic data of nipple discharge fluid cytology compared with the histopathology gold standard. Data from studies published from 1956 to 2019 were analyzed. The analysis included 8648 cytology samples of women with a presenting complaint of nipple discharge. Both hierarchical and bivariate models for diagnostic meta-analysis were used to attain overall pooled sensitivity and specificity. RESULTS: Of 837 studies retrieved, 45 fulfilled the criteria for inclusion. The diagnostic accuracy of the meta-analysis examining nipple discharge fluid had a sensitivity of 75 % (95 % confidence interval [CI], 0.74–0.77) and a specificity of 87 % (95 % CI, 0.86–0.87) for benign breast disease. For breast cancer, it had a sensitivity of 62 % (95 % CI, 0.53–0.71) and a specificity 71 % (95 % CI, 0.57–0.81). Furthermore, patients presenting with blood-stained discharge yielded an overall malignancy rate of 58 % (95 % CI, 0.54–0.60) with a positive predictive value (PPV) of 27 % (95 % CI, 0.17–0.36). CONCLUSIONS: Pooled data from studies encompassing nipple discharge fluid assessment suggest that nipple smear cytology is of limited diagnostic accuracy. The authors recommend that a tailored approach to diagnosis be required given the variable sensitivities of currently available tests. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1245/s10434-021-11070-2. Springer International Publishing 2021-11-27 2022 /pmc/articles/PMC8627297/ /pubmed/34839426 http://dx.doi.org/10.1245/s10434-021-11070-2 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Breast Oncology Jiwa, Natasha Kumar, Swathica Gandhewar, Rishikesh Chauhan, Hemali Nagarajan, Vikneswaran Wright, Corrina Hadjiminas, Dimitri Takats, Zoltan Ashrafian, Hutan Leff, Daniel Richard Diagnostic Accuracy of Nipple Discharge Fluid Cytology: A Meta-Analysis and Systematic Review of the Literature |
title | Diagnostic Accuracy of Nipple Discharge Fluid Cytology: A Meta-Analysis and Systematic Review of the Literature |
title_full | Diagnostic Accuracy of Nipple Discharge Fluid Cytology: A Meta-Analysis and Systematic Review of the Literature |
title_fullStr | Diagnostic Accuracy of Nipple Discharge Fluid Cytology: A Meta-Analysis and Systematic Review of the Literature |
title_full_unstemmed | Diagnostic Accuracy of Nipple Discharge Fluid Cytology: A Meta-Analysis and Systematic Review of the Literature |
title_short | Diagnostic Accuracy of Nipple Discharge Fluid Cytology: A Meta-Analysis and Systematic Review of the Literature |
title_sort | diagnostic accuracy of nipple discharge fluid cytology: a meta-analysis and systematic review of the literature |
topic | Breast Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8627297/ https://www.ncbi.nlm.nih.gov/pubmed/34839426 http://dx.doi.org/10.1245/s10434-021-11070-2 |
work_keys_str_mv | AT jiwanatasha diagnosticaccuracyofnippledischargefluidcytologyametaanalysisandsystematicreviewoftheliterature AT kumarswathica diagnosticaccuracyofnippledischargefluidcytologyametaanalysisandsystematicreviewoftheliterature AT gandhewarrishikesh diagnosticaccuracyofnippledischargefluidcytologyametaanalysisandsystematicreviewoftheliterature AT chauhanhemali diagnosticaccuracyofnippledischargefluidcytologyametaanalysisandsystematicreviewoftheliterature AT nagarajanvikneswaran diagnosticaccuracyofnippledischargefluidcytologyametaanalysisandsystematicreviewoftheliterature AT wrightcorrina diagnosticaccuracyofnippledischargefluidcytologyametaanalysisandsystematicreviewoftheliterature AT hadjiminasdimitri diagnosticaccuracyofnippledischargefluidcytologyametaanalysisandsystematicreviewoftheliterature AT takatszoltan diagnosticaccuracyofnippledischargefluidcytologyametaanalysisandsystematicreviewoftheliterature AT ashrafianhutan diagnosticaccuracyofnippledischargefluidcytologyametaanalysisandsystematicreviewoftheliterature AT leffdanielrichard diagnosticaccuracyofnippledischargefluidcytologyametaanalysisandsystematicreviewoftheliterature |