Cargando…
Pattern Electroretinogram Parameters Are Associated with Optic Nerve Morphology in Preperimetric Glaucoma after Adjusting for Disc Area
PURPOSE: We examined the relationships between pattern electroretinogram and optical coherence tomography derived optic nerve head measurements, after controlling for disc area. METHODS: Thirty-two eyes from 20 subjects with preperimetric glaucoma underwent pattern electroretinogram and optical cohe...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8627351/ https://www.ncbi.nlm.nih.gov/pubmed/34845426 http://dx.doi.org/10.1155/2021/8025337 |
_version_ | 1784606837079801856 |
---|---|
author | Tirsi, Andrew Gliagias, Vasiliki Moehringer, Julie Orshan, Derek Tello, Sofia Derr, Peter Park, Sung Chul Obstbaum, Stephen A Tello, Celso |
author_facet | Tirsi, Andrew Gliagias, Vasiliki Moehringer, Julie Orshan, Derek Tello, Sofia Derr, Peter Park, Sung Chul Obstbaum, Stephen A Tello, Celso |
author_sort | Tirsi, Andrew |
collection | PubMed |
description | PURPOSE: We examined the relationships between pattern electroretinogram and optical coherence tomography derived optic nerve head measurements, after controlling for disc area. METHODS: Thirty-two eyes from 20 subjects with preperimetric glaucoma underwent pattern electroretinogram and optical coherence tomography. Pattern electroretinogram parameters (Magnitude, MagnitudeD, and MagnitudeD/Magnitude ratio) and optic nerve head measurements (rim area, average cup to disc ratio, vertical cup to disc ratio, cup volume, retinal nerve fiber layer thickness sectors, and Bruch's membrane opening-minimum rim width thickness sectors) were analyzed after controlling for disc area. RESULTS: Magnitude and MagnitudeD were significantly associated with rim area (r ≥ 0.503, p ≤ 0.004). All pattern electroretinogram parameters significantly correlated with Bruch's membrane opening-minimum rim width sectors—temporal superior and nasal inferior (r = 0.400, p=0.039)—and retinal nerve fiber layer sectors—superior, nasal superior, and inferior (r ≥ 0.428, p ≤ 0.026). Magnitude and MagnitudeD explained an additional 26.8% and 25.2% of variance in rim area (B = 0.174 (95% CI: 0.065, 0.283), p=0.003, and B = 0.160 (95% CI: 0.056, 0.265), p=0.004), respectively. MagnitudeD and MagnitudeD/Magnitude ratio explained an additional 13.4% and 12.8% of the variance in Bruch's membrane opening-minimum rim width global (B = 38.921 [95% CI: 3.872, 73.970], p=0.031, and B = 129.024 (95% CI: 9.589, 248.460), p=0.035), respectively. All Bruch's membrane opening-minimum rim width sectors and retinal nerve fiber layer sectors (nasal superior, nasal inferior, and inferior) were significantly correlated with rim area (r ≥ 0.389, p ≤ 0.045). CONCLUSION: PERG abnormalities can predict rim area loss in preperimetric glaucoma after controlling for disc area. We recommend controlling for disc area to increase diagnostic accuracy in early glaucoma. |
format | Online Article Text |
id | pubmed-8627351 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-86273512021-11-28 Pattern Electroretinogram Parameters Are Associated with Optic Nerve Morphology in Preperimetric Glaucoma after Adjusting for Disc Area Tirsi, Andrew Gliagias, Vasiliki Moehringer, Julie Orshan, Derek Tello, Sofia Derr, Peter Park, Sung Chul Obstbaum, Stephen A Tello, Celso J Ophthalmol Research Article PURPOSE: We examined the relationships between pattern electroretinogram and optical coherence tomography derived optic nerve head measurements, after controlling for disc area. METHODS: Thirty-two eyes from 20 subjects with preperimetric glaucoma underwent pattern electroretinogram and optical coherence tomography. Pattern electroretinogram parameters (Magnitude, MagnitudeD, and MagnitudeD/Magnitude ratio) and optic nerve head measurements (rim area, average cup to disc ratio, vertical cup to disc ratio, cup volume, retinal nerve fiber layer thickness sectors, and Bruch's membrane opening-minimum rim width thickness sectors) were analyzed after controlling for disc area. RESULTS: Magnitude and MagnitudeD were significantly associated with rim area (r ≥ 0.503, p ≤ 0.004). All pattern electroretinogram parameters significantly correlated with Bruch's membrane opening-minimum rim width sectors—temporal superior and nasal inferior (r = 0.400, p=0.039)—and retinal nerve fiber layer sectors—superior, nasal superior, and inferior (r ≥ 0.428, p ≤ 0.026). Magnitude and MagnitudeD explained an additional 26.8% and 25.2% of variance in rim area (B = 0.174 (95% CI: 0.065, 0.283), p=0.003, and B = 0.160 (95% CI: 0.056, 0.265), p=0.004), respectively. MagnitudeD and MagnitudeD/Magnitude ratio explained an additional 13.4% and 12.8% of the variance in Bruch's membrane opening-minimum rim width global (B = 38.921 [95% CI: 3.872, 73.970], p=0.031, and B = 129.024 (95% CI: 9.589, 248.460), p=0.035), respectively. All Bruch's membrane opening-minimum rim width sectors and retinal nerve fiber layer sectors (nasal superior, nasal inferior, and inferior) were significantly correlated with rim area (r ≥ 0.389, p ≤ 0.045). CONCLUSION: PERG abnormalities can predict rim area loss in preperimetric glaucoma after controlling for disc area. We recommend controlling for disc area to increase diagnostic accuracy in early glaucoma. Hindawi 2021-10-13 /pmc/articles/PMC8627351/ /pubmed/34845426 http://dx.doi.org/10.1155/2021/8025337 Text en Copyright © 2021 Andrew Tirsi et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Tirsi, Andrew Gliagias, Vasiliki Moehringer, Julie Orshan, Derek Tello, Sofia Derr, Peter Park, Sung Chul Obstbaum, Stephen A Tello, Celso Pattern Electroretinogram Parameters Are Associated with Optic Nerve Morphology in Preperimetric Glaucoma after Adjusting for Disc Area |
title | Pattern Electroretinogram Parameters Are Associated with Optic Nerve Morphology in Preperimetric Glaucoma after Adjusting for Disc Area |
title_full | Pattern Electroretinogram Parameters Are Associated with Optic Nerve Morphology in Preperimetric Glaucoma after Adjusting for Disc Area |
title_fullStr | Pattern Electroretinogram Parameters Are Associated with Optic Nerve Morphology in Preperimetric Glaucoma after Adjusting for Disc Area |
title_full_unstemmed | Pattern Electroretinogram Parameters Are Associated with Optic Nerve Morphology in Preperimetric Glaucoma after Adjusting for Disc Area |
title_short | Pattern Electroretinogram Parameters Are Associated with Optic Nerve Morphology in Preperimetric Glaucoma after Adjusting for Disc Area |
title_sort | pattern electroretinogram parameters are associated with optic nerve morphology in preperimetric glaucoma after adjusting for disc area |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8627351/ https://www.ncbi.nlm.nih.gov/pubmed/34845426 http://dx.doi.org/10.1155/2021/8025337 |
work_keys_str_mv | AT tirsiandrew patternelectroretinogramparametersareassociatedwithopticnervemorphologyinpreperimetricglaucomaafteradjustingfordiscarea AT gliagiasvasiliki patternelectroretinogramparametersareassociatedwithopticnervemorphologyinpreperimetricglaucomaafteradjustingfordiscarea AT moehringerjulie patternelectroretinogramparametersareassociatedwithopticnervemorphologyinpreperimetricglaucomaafteradjustingfordiscarea AT orshanderek patternelectroretinogramparametersareassociatedwithopticnervemorphologyinpreperimetricglaucomaafteradjustingfordiscarea AT tellosofia patternelectroretinogramparametersareassociatedwithopticnervemorphologyinpreperimetricglaucomaafteradjustingfordiscarea AT derrpeter patternelectroretinogramparametersareassociatedwithopticnervemorphologyinpreperimetricglaucomaafteradjustingfordiscarea AT parksungchul patternelectroretinogramparametersareassociatedwithopticnervemorphologyinpreperimetricglaucomaafteradjustingfordiscarea AT obstbaumstephena patternelectroretinogramparametersareassociatedwithopticnervemorphologyinpreperimetricglaucomaafteradjustingfordiscarea AT tellocelso patternelectroretinogramparametersareassociatedwithopticnervemorphologyinpreperimetricglaucomaafteradjustingfordiscarea |