Early Benchmarking Total Hip Arthroplasty Implants Using Data from the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI)
BACKGROUND: Benchmarking arthroplasty implant revision risk is an informative way to address implant performance. National benchmarking efforts exist in the United Kingdom, Netherlands, and Australia. Recently, the International Prosthesis Benchmarking Working Group, including representatives from i...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8627892/ https://www.ncbi.nlm.nih.gov/pubmed/34853539 http://dx.doi.org/10.2147/ORR.S325042 |
_version_ | 1784606907601780736 |
---|---|
author | Chubb, Heather A Cornish, Eric R Hallstrom, Brian R Hughes, Richard E |
author_facet | Chubb, Heather A Cornish, Eric R Hallstrom, Brian R Hughes, Richard E |
author_sort | Chubb, Heather A |
collection | PubMed |
description | BACKGROUND: Benchmarking arthroplasty implant revision risk is an informative way to address implant performance. National benchmarking efforts exist in the United Kingdom, Netherlands, and Australia. Recently, the International Prosthesis Benchmarking Working Group, including representatives from industry, academia, and national registries, produced a guideline describing arthroplasty benchmarking methodology. The proposal was applied to data from the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) to assess its feasibility for benchmarking implants in the United States. METHODS: Primary elective total hip arthroplasty procedures performed for osteoarthritis between 2/15/2012 and 12/31/2018 and their associated revisions were identified in the MARCQI registry. The guidelines recommend that all prostheses combinations receive an early benchmark if they have at least 250 procedures at risk and the revision rate does not exceed the pre-determined standard of 2% at 2 years and 3% at 5 years. RESULTS: A total of 72,949 primary cases met the inclusion criteria. Of these, 1369 had revisions. Twenty-nine and six stem/cup combinations satisfied the minimum case requirement at 2 and 5 years, respectively. Three implant combinations would not receive a benchmark at 2 years: Secur-Fit/Trident, Anthology/Reflection 3, Taperloc 133/G7. CONCLUSION: The guideline can be implemented in the United States by a regional registry. Moreover, not all hip implants currently in use would receive an early benchmark. This raises concern as these implant combinations represent a significant number of cases in Michigan, some with increasing utilization. |
format | Online Article Text |
id | pubmed-8627892 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-86278922021-11-30 Early Benchmarking Total Hip Arthroplasty Implants Using Data from the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) Chubb, Heather A Cornish, Eric R Hallstrom, Brian R Hughes, Richard E Orthop Res Rev Original Research BACKGROUND: Benchmarking arthroplasty implant revision risk is an informative way to address implant performance. National benchmarking efforts exist in the United Kingdom, Netherlands, and Australia. Recently, the International Prosthesis Benchmarking Working Group, including representatives from industry, academia, and national registries, produced a guideline describing arthroplasty benchmarking methodology. The proposal was applied to data from the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) to assess its feasibility for benchmarking implants in the United States. METHODS: Primary elective total hip arthroplasty procedures performed for osteoarthritis between 2/15/2012 and 12/31/2018 and their associated revisions were identified in the MARCQI registry. The guidelines recommend that all prostheses combinations receive an early benchmark if they have at least 250 procedures at risk and the revision rate does not exceed the pre-determined standard of 2% at 2 years and 3% at 5 years. RESULTS: A total of 72,949 primary cases met the inclusion criteria. Of these, 1369 had revisions. Twenty-nine and six stem/cup combinations satisfied the minimum case requirement at 2 and 5 years, respectively. Three implant combinations would not receive a benchmark at 2 years: Secur-Fit/Trident, Anthology/Reflection 3, Taperloc 133/G7. CONCLUSION: The guideline can be implemented in the United States by a regional registry. Moreover, not all hip implants currently in use would receive an early benchmark. This raises concern as these implant combinations represent a significant number of cases in Michigan, some with increasing utilization. Dove 2021-11-24 /pmc/articles/PMC8627892/ /pubmed/34853539 http://dx.doi.org/10.2147/ORR.S325042 Text en © 2021 Chubb et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Chubb, Heather A Cornish, Eric R Hallstrom, Brian R Hughes, Richard E Early Benchmarking Total Hip Arthroplasty Implants Using Data from the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) |
title | Early Benchmarking Total Hip Arthroplasty Implants Using Data from the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) |
title_full | Early Benchmarking Total Hip Arthroplasty Implants Using Data from the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) |
title_fullStr | Early Benchmarking Total Hip Arthroplasty Implants Using Data from the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) |
title_full_unstemmed | Early Benchmarking Total Hip Arthroplasty Implants Using Data from the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) |
title_short | Early Benchmarking Total Hip Arthroplasty Implants Using Data from the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI) |
title_sort | early benchmarking total hip arthroplasty implants using data from the michigan arthroplasty registry collaborative quality initiative (marcqi) |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8627892/ https://www.ncbi.nlm.nih.gov/pubmed/34853539 http://dx.doi.org/10.2147/ORR.S325042 |
work_keys_str_mv | AT chubbheathera earlybenchmarkingtotalhiparthroplastyimplantsusingdatafromthemichiganarthroplastyregistrycollaborativequalityinitiativemarcqi AT cornishericr earlybenchmarkingtotalhiparthroplastyimplantsusingdatafromthemichiganarthroplastyregistrycollaborativequalityinitiativemarcqi AT hallstrombrianr earlybenchmarkingtotalhiparthroplastyimplantsusingdatafromthemichiganarthroplastyregistrycollaborativequalityinitiativemarcqi AT hughesricharde earlybenchmarkingtotalhiparthroplastyimplantsusingdatafromthemichiganarthroplastyregistrycollaborativequalityinitiativemarcqi |