Cargando…
Low cut-off value of serum (1,3)-beta-d-glucan for the diagnosis of Pneumocystis pneumonia in non-HIV patients: a retrospective cohort study
BACKGROUND: Non-human immunodeficiency virus (HIV) Pneumocystis pneumonia (PCP) is a fulminant disease with an increasing incidence. The serum beta-d-glucan (BDG) assay is used as an adjunct to the diagnosis of PCP; however, the cut-off value for this assay is not well-defined, especially in the non...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8628137/ https://www.ncbi.nlm.nih.gov/pubmed/34844554 http://dx.doi.org/10.1186/s12879-021-06895-x |
Sumario: | BACKGROUND: Non-human immunodeficiency virus (HIV) Pneumocystis pneumonia (PCP) is a fulminant disease with an increasing incidence. The serum beta-d-glucan (BDG) assay is used as an adjunct to the diagnosis of PCP; however, the cut-off value for this assay is not well-defined, especially in the non-HIV PCP population. Therefore, we aimed to identify the assay cut-off value for this population. METHODS: In this retrospective observational study, we reviewed the medical records of all patients (≥ 18 years old) with clinical suspicion of PCP who underwent evaluation of respiratory tract specimens between December 2008 and June 2014 at Kameda Medical Center. We created a receiver operating characteristic curve and calculated the area under the curve to determine the cut-off value for evaluating the inspection accuracy of the BDG assay. RESULTS: A total of 173 patients were included in the study. Fifty patients showed positive results in specimen staining, loop-mediated isothermal amplification assay, and polymerase chain reaction test, while 123 patients showed negative results. The receiver operating characteristic analyses suggested that the BDG cut-off level was 8.5 pg/mL, with a sensitivity and specificity of 76% and 76%, respectively. CONCLUSIONS: The Wako-BDG cut-off value for the diagnosis of non-HIV PCP is 8.5 pg/mL, which is lower than the classical cut-off value from previous studies. Clinicians should potentially consider this lower BDG cut-off value in the diagnosis and management of patients with non-HIV PCP. Trial registration: The participants were retrospectively registered. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12879-021-06895-x. |
---|