Cargando…

Low cut-off value of serum (1,3)-beta-d-glucan for the diagnosis of Pneumocystis pneumonia in non-HIV patients: a retrospective cohort study

BACKGROUND: Non-human immunodeficiency virus (HIV) Pneumocystis pneumonia (PCP) is a fulminant disease with an increasing incidence. The serum beta-d-glucan (BDG) assay is used as an adjunct to the diagnosis of PCP; however, the cut-off value for this assay is not well-defined, especially in the non...

Descripción completa

Detalles Bibliográficos
Autores principales: Taniguchi, Jumpei, Nakashima, Kei, Matsui, Hiroki, Watari, Tomohisa, Otsuki, Ayumu, Ito, Hiroyuki, Otsuka, Yoshihito
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8628137/
https://www.ncbi.nlm.nih.gov/pubmed/34844554
http://dx.doi.org/10.1186/s12879-021-06895-x
_version_ 1784606958656946176
author Taniguchi, Jumpei
Nakashima, Kei
Matsui, Hiroki
Watari, Tomohisa
Otsuki, Ayumu
Ito, Hiroyuki
Otsuka, Yoshihito
author_facet Taniguchi, Jumpei
Nakashima, Kei
Matsui, Hiroki
Watari, Tomohisa
Otsuki, Ayumu
Ito, Hiroyuki
Otsuka, Yoshihito
author_sort Taniguchi, Jumpei
collection PubMed
description BACKGROUND: Non-human immunodeficiency virus (HIV) Pneumocystis pneumonia (PCP) is a fulminant disease with an increasing incidence. The serum beta-d-glucan (BDG) assay is used as an adjunct to the diagnosis of PCP; however, the cut-off value for this assay is not well-defined, especially in the non-HIV PCP population. Therefore, we aimed to identify the assay cut-off value for this population. METHODS: In this retrospective observational study, we reviewed the medical records of all patients (≥ 18 years old) with clinical suspicion of PCP who underwent evaluation of respiratory tract specimens between December 2008 and June 2014 at Kameda Medical Center. We created a receiver operating characteristic curve and calculated the area under the curve to determine the cut-off value for evaluating the inspection accuracy of the BDG assay. RESULTS: A total of 173 patients were included in the study. Fifty patients showed positive results in specimen staining, loop-mediated isothermal amplification assay, and polymerase chain reaction test, while 123 patients showed negative results. The receiver operating characteristic analyses suggested that the BDG cut-off level was 8.5 pg/mL, with a sensitivity and specificity of 76% and 76%, respectively. CONCLUSIONS: The Wako-BDG cut-off value for the diagnosis of non-HIV PCP is 8.5 pg/mL, which is lower than the classical cut-off value from previous studies. Clinicians should potentially consider this lower BDG cut-off value in the diagnosis and management of patients with non-HIV PCP. Trial registration: The participants were retrospectively registered. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12879-021-06895-x.
format Online
Article
Text
id pubmed-8628137
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-86281372021-11-29 Low cut-off value of serum (1,3)-beta-d-glucan for the diagnosis of Pneumocystis pneumonia in non-HIV patients: a retrospective cohort study Taniguchi, Jumpei Nakashima, Kei Matsui, Hiroki Watari, Tomohisa Otsuki, Ayumu Ito, Hiroyuki Otsuka, Yoshihito BMC Infect Dis Research BACKGROUND: Non-human immunodeficiency virus (HIV) Pneumocystis pneumonia (PCP) is a fulminant disease with an increasing incidence. The serum beta-d-glucan (BDG) assay is used as an adjunct to the diagnosis of PCP; however, the cut-off value for this assay is not well-defined, especially in the non-HIV PCP population. Therefore, we aimed to identify the assay cut-off value for this population. METHODS: In this retrospective observational study, we reviewed the medical records of all patients (≥ 18 years old) with clinical suspicion of PCP who underwent evaluation of respiratory tract specimens between December 2008 and June 2014 at Kameda Medical Center. We created a receiver operating characteristic curve and calculated the area under the curve to determine the cut-off value for evaluating the inspection accuracy of the BDG assay. RESULTS: A total of 173 patients were included in the study. Fifty patients showed positive results in specimen staining, loop-mediated isothermal amplification assay, and polymerase chain reaction test, while 123 patients showed negative results. The receiver operating characteristic analyses suggested that the BDG cut-off level was 8.5 pg/mL, with a sensitivity and specificity of 76% and 76%, respectively. CONCLUSIONS: The Wako-BDG cut-off value for the diagnosis of non-HIV PCP is 8.5 pg/mL, which is lower than the classical cut-off value from previous studies. Clinicians should potentially consider this lower BDG cut-off value in the diagnosis and management of patients with non-HIV PCP. Trial registration: The participants were retrospectively registered. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12879-021-06895-x. BioMed Central 2021-11-29 /pmc/articles/PMC8628137/ /pubmed/34844554 http://dx.doi.org/10.1186/s12879-021-06895-x Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Taniguchi, Jumpei
Nakashima, Kei
Matsui, Hiroki
Watari, Tomohisa
Otsuki, Ayumu
Ito, Hiroyuki
Otsuka, Yoshihito
Low cut-off value of serum (1,3)-beta-d-glucan for the diagnosis of Pneumocystis pneumonia in non-HIV patients: a retrospective cohort study
title Low cut-off value of serum (1,3)-beta-d-glucan for the diagnosis of Pneumocystis pneumonia in non-HIV patients: a retrospective cohort study
title_full Low cut-off value of serum (1,3)-beta-d-glucan for the diagnosis of Pneumocystis pneumonia in non-HIV patients: a retrospective cohort study
title_fullStr Low cut-off value of serum (1,3)-beta-d-glucan for the diagnosis of Pneumocystis pneumonia in non-HIV patients: a retrospective cohort study
title_full_unstemmed Low cut-off value of serum (1,3)-beta-d-glucan for the diagnosis of Pneumocystis pneumonia in non-HIV patients: a retrospective cohort study
title_short Low cut-off value of serum (1,3)-beta-d-glucan for the diagnosis of Pneumocystis pneumonia in non-HIV patients: a retrospective cohort study
title_sort low cut-off value of serum (1,3)-beta-d-glucan for the diagnosis of pneumocystis pneumonia in non-hiv patients: a retrospective cohort study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8628137/
https://www.ncbi.nlm.nih.gov/pubmed/34844554
http://dx.doi.org/10.1186/s12879-021-06895-x
work_keys_str_mv AT taniguchijumpei lowcutoffvalueofserum13betadglucanforthediagnosisofpneumocystispneumoniainnonhivpatientsaretrospectivecohortstudy
AT nakashimakei lowcutoffvalueofserum13betadglucanforthediagnosisofpneumocystispneumoniainnonhivpatientsaretrospectivecohortstudy
AT matsuihiroki lowcutoffvalueofserum13betadglucanforthediagnosisofpneumocystispneumoniainnonhivpatientsaretrospectivecohortstudy
AT wataritomohisa lowcutoffvalueofserum13betadglucanforthediagnosisofpneumocystispneumoniainnonhivpatientsaretrospectivecohortstudy
AT otsukiayumu lowcutoffvalueofserum13betadglucanforthediagnosisofpneumocystispneumoniainnonhivpatientsaretrospectivecohortstudy
AT itohiroyuki lowcutoffvalueofserum13betadglucanforthediagnosisofpneumocystispneumoniainnonhivpatientsaretrospectivecohortstudy
AT otsukayoshihito lowcutoffvalueofserum13betadglucanforthediagnosisofpneumocystispneumoniainnonhivpatientsaretrospectivecohortstudy