Cargando…

Tissue Adequacy and Safety of Percutaneous Transthoracic Needle Biopsy for Molecular Analysis in Non-Small Cell Lung Cancer: A Systematic Review and Meta-analysis

OBJECTIVE: We conducted a systematic review and meta-analysis of the tissue adequacy and complication rates of percutaneous transthoracic needle biopsy (PTNB) for molecular analysis in patients with non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: We performed a literature search of the OV...

Descripción completa

Detalles Bibliográficos
Autores principales: Nam, Bo Da, Yoon, Soon Ho, Hong, Hyunsook, Hwang, Jung Hwa, Goo, Jin Mo, Park, Suyeon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8628152/
https://www.ncbi.nlm.nih.gov/pubmed/34564960
http://dx.doi.org/10.3348/kjr.2021.0244
_version_ 1784606962015535104
author Nam, Bo Da
Yoon, Soon Ho
Hong, Hyunsook
Hwang, Jung Hwa
Goo, Jin Mo
Park, Suyeon
author_facet Nam, Bo Da
Yoon, Soon Ho
Hong, Hyunsook
Hwang, Jung Hwa
Goo, Jin Mo
Park, Suyeon
author_sort Nam, Bo Da
collection PubMed
description OBJECTIVE: We conducted a systematic review and meta-analysis of the tissue adequacy and complication rates of percutaneous transthoracic needle biopsy (PTNB) for molecular analysis in patients with non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: We performed a literature search of the OVID-MEDLINE and Embase databases to identify original studies on the tissue adequacy and complication rates of PTNB for molecular analysis in patients with NSCLC published between January 2005 and January 2020. Inverse variance and random-effects models were used to evaluate and acquire meta-analytic estimates of the outcomes. To explore heterogeneity across the studies, univariable and multivariable meta-regression analyses were performed. RESULTS: A total of 21 studies with 2232 biopsies (initial biopsy, 8 studies; rebiopsy after therapy, 13 studies) were included. The pooled rates of tissue adequacy and complications were 89.3% (95% confidence interval [CI]: 85.6%–92.6%; I(2) = 0.81) and 17.3% (95% CI: 12.1%–23.1%; I(2) = 0.89), respectively. These rates were 93.5% and 22.2% for the initial biopsies and 86.2% and 16.8% for the rebiopsies, respectively. Severe complications, including pneumothorax requiring chest tube placement and massive hemoptysis, occurred in 0.7% of the cases (95% CI: 0%–2.2%; I(2) = 0.67). Multivariable meta-regression analysis showed that the tissue adequacy rate was not significantly lower in studies on rebiopsies (p = 0.058). The complication rate was significantly higher in studies that preferentially included older adults (p = 0.001). CONCLUSION: PTNB demonstrated an average tissue adequacy rate of 89.3% for molecular analysis in patients with NSCLC, with a complication rate of 17.3%. PTNB is a generally safe and effective diagnostic procedure for obtaining tissue samples for molecular analysis in NSCLC. Rebiopsy may be performed actively with an acceptable risk of complications if clinically required.
format Online
Article
Text
id pubmed-8628152
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-86281522021-12-07 Tissue Adequacy and Safety of Percutaneous Transthoracic Needle Biopsy for Molecular Analysis in Non-Small Cell Lung Cancer: A Systematic Review and Meta-analysis Nam, Bo Da Yoon, Soon Ho Hong, Hyunsook Hwang, Jung Hwa Goo, Jin Mo Park, Suyeon Korean J Radiol Thoracic Imaging OBJECTIVE: We conducted a systematic review and meta-analysis of the tissue adequacy and complication rates of percutaneous transthoracic needle biopsy (PTNB) for molecular analysis in patients with non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: We performed a literature search of the OVID-MEDLINE and Embase databases to identify original studies on the tissue adequacy and complication rates of PTNB for molecular analysis in patients with NSCLC published between January 2005 and January 2020. Inverse variance and random-effects models were used to evaluate and acquire meta-analytic estimates of the outcomes. To explore heterogeneity across the studies, univariable and multivariable meta-regression analyses were performed. RESULTS: A total of 21 studies with 2232 biopsies (initial biopsy, 8 studies; rebiopsy after therapy, 13 studies) were included. The pooled rates of tissue adequacy and complications were 89.3% (95% confidence interval [CI]: 85.6%–92.6%; I(2) = 0.81) and 17.3% (95% CI: 12.1%–23.1%; I(2) = 0.89), respectively. These rates were 93.5% and 22.2% for the initial biopsies and 86.2% and 16.8% for the rebiopsies, respectively. Severe complications, including pneumothorax requiring chest tube placement and massive hemoptysis, occurred in 0.7% of the cases (95% CI: 0%–2.2%; I(2) = 0.67). Multivariable meta-regression analysis showed that the tissue adequacy rate was not significantly lower in studies on rebiopsies (p = 0.058). The complication rate was significantly higher in studies that preferentially included older adults (p = 0.001). CONCLUSION: PTNB demonstrated an average tissue adequacy rate of 89.3% for molecular analysis in patients with NSCLC, with a complication rate of 17.3%. PTNB is a generally safe and effective diagnostic procedure for obtaining tissue samples for molecular analysis in NSCLC. Rebiopsy may be performed actively with an acceptable risk of complications if clinically required. The Korean Society of Radiology 2021-12 2021-08-31 /pmc/articles/PMC8628152/ /pubmed/34564960 http://dx.doi.org/10.3348/kjr.2021.0244 Text en Copyright © 2021 The Korean Society of Radiology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Thoracic Imaging
Nam, Bo Da
Yoon, Soon Ho
Hong, Hyunsook
Hwang, Jung Hwa
Goo, Jin Mo
Park, Suyeon
Tissue Adequacy and Safety of Percutaneous Transthoracic Needle Biopsy for Molecular Analysis in Non-Small Cell Lung Cancer: A Systematic Review and Meta-analysis
title Tissue Adequacy and Safety of Percutaneous Transthoracic Needle Biopsy for Molecular Analysis in Non-Small Cell Lung Cancer: A Systematic Review and Meta-analysis
title_full Tissue Adequacy and Safety of Percutaneous Transthoracic Needle Biopsy for Molecular Analysis in Non-Small Cell Lung Cancer: A Systematic Review and Meta-analysis
title_fullStr Tissue Adequacy and Safety of Percutaneous Transthoracic Needle Biopsy for Molecular Analysis in Non-Small Cell Lung Cancer: A Systematic Review and Meta-analysis
title_full_unstemmed Tissue Adequacy and Safety of Percutaneous Transthoracic Needle Biopsy for Molecular Analysis in Non-Small Cell Lung Cancer: A Systematic Review and Meta-analysis
title_short Tissue Adequacy and Safety of Percutaneous Transthoracic Needle Biopsy for Molecular Analysis in Non-Small Cell Lung Cancer: A Systematic Review and Meta-analysis
title_sort tissue adequacy and safety of percutaneous transthoracic needle biopsy for molecular analysis in non-small cell lung cancer: a systematic review and meta-analysis
topic Thoracic Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8628152/
https://www.ncbi.nlm.nih.gov/pubmed/34564960
http://dx.doi.org/10.3348/kjr.2021.0244
work_keys_str_mv AT namboda tissueadequacyandsafetyofpercutaneoustransthoracicneedlebiopsyformolecularanalysisinnonsmallcelllungcancerasystematicreviewandmetaanalysis
AT yoonsoonho tissueadequacyandsafetyofpercutaneoustransthoracicneedlebiopsyformolecularanalysisinnonsmallcelllungcancerasystematicreviewandmetaanalysis
AT honghyunsook tissueadequacyandsafetyofpercutaneoustransthoracicneedlebiopsyformolecularanalysisinnonsmallcelllungcancerasystematicreviewandmetaanalysis
AT hwangjunghwa tissueadequacyandsafetyofpercutaneoustransthoracicneedlebiopsyformolecularanalysisinnonsmallcelllungcancerasystematicreviewandmetaanalysis
AT goojinmo tissueadequacyandsafetyofpercutaneoustransthoracicneedlebiopsyformolecularanalysisinnonsmallcelllungcancerasystematicreviewandmetaanalysis
AT parksuyeon tissueadequacyandsafetyofpercutaneoustransthoracicneedlebiopsyformolecularanalysisinnonsmallcelllungcancerasystematicreviewandmetaanalysis