A Short Dynamic Scan Method of Measuring Bone Metabolic Flux Using [(18)F]NaF PET

[(18)F]NaF PET measurements of bone metabolic flux (K(i)) are conventionally obtained with 60-min dynamic scans analysed using the Hawkins model. However, long scan times make this method expensive and uncomfortable for subjects. Therefore, we evaluated and compared measurements of K(i) with shorter...

Descripción completa

Detalles Bibliográficos
Autores principales: Puri, Tanuj, Siddique, Musib M., Frost, Michelle L., Moore, Amelia E. B., Blake, Glen M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8628944/
https://www.ncbi.nlm.nih.gov/pubmed/34842815
http://dx.doi.org/10.3390/tomography7040053
_version_ 1784607102999724032
author Puri, Tanuj
Siddique, Musib M.
Frost, Michelle L.
Moore, Amelia E. B.
Blake, Glen M.
author_facet Puri, Tanuj
Siddique, Musib M.
Frost, Michelle L.
Moore, Amelia E. B.
Blake, Glen M.
author_sort Puri, Tanuj
collection PubMed
description [(18)F]NaF PET measurements of bone metabolic flux (K(i)) are conventionally obtained with 60-min dynamic scans analysed using the Hawkins model. However, long scan times make this method expensive and uncomfortable for subjects. Therefore, we evaluated and compared measurements of K(i) with shorter scan times analysed with fixed values of the Hawkins model rate constants. The scans were acquired in a trial in 30 postmenopausal women, half treated with teriparatide (TPT) and half untreated. Sixty-minute PET-CT scans of both hips were acquired at baseline and week 12 after injection with 180 MBq [(18)F]NaF. Scans were analysed using the Hawkins model by fitting bone time–activity curves at seven volumes of interest (VOIs) with a semi-population arterial input function. The model was re-run with fixed rate-constants for dynamic scan times from 0–12 min increasing in 4-min steps up to 0–60 min. Using the Hawkins model with fixed rate-constants, K(i) measurements with statistical power equivalent or superior to conventionally analysed 60-min dynamic scans were obtained with scan times as short as 12 min.
format Online
Article
Text
id pubmed-8628944
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86289442021-11-30 A Short Dynamic Scan Method of Measuring Bone Metabolic Flux Using [(18)F]NaF PET Puri, Tanuj Siddique, Musib M. Frost, Michelle L. Moore, Amelia E. B. Blake, Glen M. Tomography Article [(18)F]NaF PET measurements of bone metabolic flux (K(i)) are conventionally obtained with 60-min dynamic scans analysed using the Hawkins model. However, long scan times make this method expensive and uncomfortable for subjects. Therefore, we evaluated and compared measurements of K(i) with shorter scan times analysed with fixed values of the Hawkins model rate constants. The scans were acquired in a trial in 30 postmenopausal women, half treated with teriparatide (TPT) and half untreated. Sixty-minute PET-CT scans of both hips were acquired at baseline and week 12 after injection with 180 MBq [(18)F]NaF. Scans were analysed using the Hawkins model by fitting bone time–activity curves at seven volumes of interest (VOIs) with a semi-population arterial input function. The model was re-run with fixed rate-constants for dynamic scan times from 0–12 min increasing in 4-min steps up to 0–60 min. Using the Hawkins model with fixed rate-constants, K(i) measurements with statistical power equivalent or superior to conventionally analysed 60-min dynamic scans were obtained with scan times as short as 12 min. MDPI 2021-10-25 /pmc/articles/PMC8628944/ /pubmed/34842815 http://dx.doi.org/10.3390/tomography7040053 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Puri, Tanuj
Siddique, Musib M.
Frost, Michelle L.
Moore, Amelia E. B.
Blake, Glen M.
A Short Dynamic Scan Method of Measuring Bone Metabolic Flux Using [(18)F]NaF PET
title A Short Dynamic Scan Method of Measuring Bone Metabolic Flux Using [(18)F]NaF PET
title_full A Short Dynamic Scan Method of Measuring Bone Metabolic Flux Using [(18)F]NaF PET
title_fullStr A Short Dynamic Scan Method of Measuring Bone Metabolic Flux Using [(18)F]NaF PET
title_full_unstemmed A Short Dynamic Scan Method of Measuring Bone Metabolic Flux Using [(18)F]NaF PET
title_short A Short Dynamic Scan Method of Measuring Bone Metabolic Flux Using [(18)F]NaF PET
title_sort short dynamic scan method of measuring bone metabolic flux using [(18)f]naf pet
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8628944/
https://www.ncbi.nlm.nih.gov/pubmed/34842815
http://dx.doi.org/10.3390/tomography7040053
work_keys_str_mv AT puritanuj ashortdynamicscanmethodofmeasuringbonemetabolicfluxusing18fnafpet
AT siddiquemusibm ashortdynamicscanmethodofmeasuringbonemetabolicfluxusing18fnafpet
AT frostmichellel ashortdynamicscanmethodofmeasuringbonemetabolicfluxusing18fnafpet
AT mooreameliaeb ashortdynamicscanmethodofmeasuringbonemetabolicfluxusing18fnafpet
AT blakeglenm ashortdynamicscanmethodofmeasuringbonemetabolicfluxusing18fnafpet
AT puritanuj shortdynamicscanmethodofmeasuringbonemetabolicfluxusing18fnafpet
AT siddiquemusibm shortdynamicscanmethodofmeasuringbonemetabolicfluxusing18fnafpet
AT frostmichellel shortdynamicscanmethodofmeasuringbonemetabolicfluxusing18fnafpet
AT mooreameliaeb shortdynamicscanmethodofmeasuringbonemetabolicfluxusing18fnafpet
AT blakeglenm shortdynamicscanmethodofmeasuringbonemetabolicfluxusing18fnafpet