The value of 3D reconstructions in determining post-operative reduction in acetabular fractures: a pilot study
BACKGROUND: In patients with acetabular fractures, the reconstructed three-dimensional (3D) model of the contralateral acetabulum could be used as a mirrored template for the anatomical configuration of the affected joint. This has not been validated. OBJECTIVE: To investigate whether the right and...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8629799/ https://www.ncbi.nlm.nih.gov/pubmed/31154463 http://dx.doi.org/10.1007/s00068-019-01148-8 |
_version_ | 1784607288461361152 |
---|---|
author | Arts, Elke Nijsink, Han Verhamme, Luc Biert, Jan Bemelman, Mike Brouwers, Lars van Wageningen, Bas |
author_facet | Arts, Elke Nijsink, Han Verhamme, Luc Biert, Jan Bemelman, Mike Brouwers, Lars van Wageningen, Bas |
author_sort | Arts, Elke |
collection | PubMed |
description | BACKGROUND: In patients with acetabular fractures, the reconstructed three-dimensional (3D) model of the contralateral acetabulum could be used as a mirrored template for the anatomical configuration of the affected joint. This has not been validated. OBJECTIVE: To investigate whether the right and left acetabula, as reconstructed 3D models, are valid mirrored duplicates that can be used as a reference model for the contralateral side. METHODS: CT scans of twenty patients with unaffected acetabula were used. The symmetry of the generated 3D models was evaluated through: (1) mirroring of the acetabulum; (2) initial rough matching; (3) automatic optimisation of the matching via surface-based matching; (4) calculation of distances between surfaces by evaluating the Euclidean (straight-line) error distance between the closest points between left and right. The percentages of surface points of the left and right acetabulum with a distance smaller than 0.5, 1.0, 1.5 and 2.0 mm were calculated and evaluated, in relation to Matta’s criteria, for acetabular fracture reductions. RESULTS: The mean distance deviation was less than 0.75 mm in all 40 comparisons. The calculated distances in 90.7% of the surface points of the left and right acetabulum were below the tolerance threshold of 1.0 mm, based on Matta’s anatomical reduction criteria, and 98.7% of the surface points scored below Matta’s imperfect tolerance threshold of 2.0 mm. CONCLUSION: This study demonstrates 3D reconstructed models of healthy left and right acetabula are highly similar and could potentially be used as mirrored duplicates. The next step will be to investigate these results in patients with reduced acetabular fractures. |
format | Online Article Text |
id | pubmed-8629799 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-86297992021-12-15 The value of 3D reconstructions in determining post-operative reduction in acetabular fractures: a pilot study Arts, Elke Nijsink, Han Verhamme, Luc Biert, Jan Bemelman, Mike Brouwers, Lars van Wageningen, Bas Eur J Trauma Emerg Surg Original Article BACKGROUND: In patients with acetabular fractures, the reconstructed three-dimensional (3D) model of the contralateral acetabulum could be used as a mirrored template for the anatomical configuration of the affected joint. This has not been validated. OBJECTIVE: To investigate whether the right and left acetabula, as reconstructed 3D models, are valid mirrored duplicates that can be used as a reference model for the contralateral side. METHODS: CT scans of twenty patients with unaffected acetabula were used. The symmetry of the generated 3D models was evaluated through: (1) mirroring of the acetabulum; (2) initial rough matching; (3) automatic optimisation of the matching via surface-based matching; (4) calculation of distances between surfaces by evaluating the Euclidean (straight-line) error distance between the closest points between left and right. The percentages of surface points of the left and right acetabulum with a distance smaller than 0.5, 1.0, 1.5 and 2.0 mm were calculated and evaluated, in relation to Matta’s criteria, for acetabular fracture reductions. RESULTS: The mean distance deviation was less than 0.75 mm in all 40 comparisons. The calculated distances in 90.7% of the surface points of the left and right acetabulum were below the tolerance threshold of 1.0 mm, based on Matta’s anatomical reduction criteria, and 98.7% of the surface points scored below Matta’s imperfect tolerance threshold of 2.0 mm. CONCLUSION: This study demonstrates 3D reconstructed models of healthy left and right acetabula are highly similar and could potentially be used as mirrored duplicates. The next step will be to investigate these results in patients with reduced acetabular fractures. Springer Berlin Heidelberg 2019-06-01 2021 /pmc/articles/PMC8629799/ /pubmed/31154463 http://dx.doi.org/10.1007/s00068-019-01148-8 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Arts, Elke Nijsink, Han Verhamme, Luc Biert, Jan Bemelman, Mike Brouwers, Lars van Wageningen, Bas The value of 3D reconstructions in determining post-operative reduction in acetabular fractures: a pilot study |
title | The value of 3D reconstructions in determining post-operative reduction in acetabular fractures: a pilot study |
title_full | The value of 3D reconstructions in determining post-operative reduction in acetabular fractures: a pilot study |
title_fullStr | The value of 3D reconstructions in determining post-operative reduction in acetabular fractures: a pilot study |
title_full_unstemmed | The value of 3D reconstructions in determining post-operative reduction in acetabular fractures: a pilot study |
title_short | The value of 3D reconstructions in determining post-operative reduction in acetabular fractures: a pilot study |
title_sort | value of 3d reconstructions in determining post-operative reduction in acetabular fractures: a pilot study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8629799/ https://www.ncbi.nlm.nih.gov/pubmed/31154463 http://dx.doi.org/10.1007/s00068-019-01148-8 |
work_keys_str_mv | AT artselke thevalueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy AT nijsinkhan thevalueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy AT verhammeluc thevalueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy AT biertjan thevalueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy AT bemelmanmike thevalueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy AT brouwerslars thevalueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy AT vanwageningenbas thevalueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy AT artselke valueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy AT nijsinkhan valueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy AT verhammeluc valueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy AT biertjan valueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy AT bemelmanmike valueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy AT brouwerslars valueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy AT vanwageningenbas valueof3dreconstructionsindeterminingpostoperativereductioninacetabularfracturesapilotstudy |