Safety and efficacy of 2D-fluoroscopy-based iliosacral screw osteosynthesis: results of a retrospective monocentric study

INTRODUCTION: Iliosacral screw osteosynthesis is a well-accepted procedure for stabilization of sacral fractures and iliosacral (fracture) dislocations. MATERIALS AND METHODS: In this monocentric study, safety and efficacy of conventional 2D-fluoroscopic-guided iliosacral screw insertion were evalua...

Descripción completa

Detalles Bibliográficos
Autores principales: Rommens, Pol Maria, Nolte, Eva Mareike, Hopf, Johannes, Wagner, Daniel, Hofmann, Alexander, Hessmann, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8629807/
https://www.ncbi.nlm.nih.gov/pubmed/32296862
http://dx.doi.org/10.1007/s00068-020-01362-9
_version_ 1784607290108674048
author Rommens, Pol Maria
Nolte, Eva Mareike
Hopf, Johannes
Wagner, Daniel
Hofmann, Alexander
Hessmann, Martin
author_facet Rommens, Pol Maria
Nolte, Eva Mareike
Hopf, Johannes
Wagner, Daniel
Hofmann, Alexander
Hessmann, Martin
author_sort Rommens, Pol Maria
collection PubMed
description INTRODUCTION: Iliosacral screw osteosynthesis is a well-accepted procedure for stabilization of sacral fractures and iliosacral (fracture) dislocations. MATERIALS AND METHODS: In this monocentric study, safety and efficacy of conventional 2D-fluoroscopic-guided iliosacral screw insertion were evaluated. RESULTS: During a 10-year period (2005–2014), 98 patients between the age of 18 and 65 years received 207 iliosacral screws in 101 procedures. Average patient age was 43.2 years. There were 46 Type B and 40 Type C injuries in the AO/OTA classification, nine patients had a fragility fracture of the pelvis. In three patients, primary radiological data were missing. The indication for surgical treatment was a sacral fracture in 97 patients, a pure iliosacral dislocation in 37 patients and a fracture-dislocation in 31 patients. 70 procedures were performed with the patient in supine position, 31 with the patient in prone position. Surgery was done in a minimal-invasive technique in 76 patients, in 22 patients an open reduction was necessary before screw insertion. 81 patients received a unilateral, 17 patients a bilateral screw osteosynthesis. 199 screws were inserted in S1, only eight screws in S2. 65 patients received two screws unilaterally, ten patients two screws bilaterally. There were no vascular or neurologic complications. During in-hospital stay, there were seven complications, which needed 12 operative revisions: three wound infections, two hematomas, one screw malalignment and one early screw loosening. In 28 patients with 56 iliosacral screws, a pelvic CT-scan was performed during follow-up. A penetration of a cortical layer was diagnosed in 20 of these screws. All penetrations were seen in double screw osteosynthesis of S1. In none of the patients, complaints could be explained by the malalignment of these screws. Five operative revisions were performed during follow-up: two for screw loosening, two for fracture healing problems and one for screw malalignment. Metal removal was performed in 39 patients with 75 screws. 2D-fluoroscopic-guided iliosacral screw osteosynthesis is a safe and efficient procedure in clinical practice. DISCUSSION: A thorough preoperative evaluation of the morphology of the upper sacrum and careful operative procedure are indispensable. Fluoroscopic views in AP, lateral, inlet and outlet must allow recognition of all anatomical landmarks. The indication for double screw osteosynthesis in S1 should be taken with caution. Screw malalignments do not inevitably correlate with complaints.
format Online
Article
Text
id pubmed-8629807
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-86298072021-12-15 Safety and efficacy of 2D-fluoroscopy-based iliosacral screw osteosynthesis: results of a retrospective monocentric study Rommens, Pol Maria Nolte, Eva Mareike Hopf, Johannes Wagner, Daniel Hofmann, Alexander Hessmann, Martin Eur J Trauma Emerg Surg Original Article INTRODUCTION: Iliosacral screw osteosynthesis is a well-accepted procedure for stabilization of sacral fractures and iliosacral (fracture) dislocations. MATERIALS AND METHODS: In this monocentric study, safety and efficacy of conventional 2D-fluoroscopic-guided iliosacral screw insertion were evaluated. RESULTS: During a 10-year period (2005–2014), 98 patients between the age of 18 and 65 years received 207 iliosacral screws in 101 procedures. Average patient age was 43.2 years. There were 46 Type B and 40 Type C injuries in the AO/OTA classification, nine patients had a fragility fracture of the pelvis. In three patients, primary radiological data were missing. The indication for surgical treatment was a sacral fracture in 97 patients, a pure iliosacral dislocation in 37 patients and a fracture-dislocation in 31 patients. 70 procedures were performed with the patient in supine position, 31 with the patient in prone position. Surgery was done in a minimal-invasive technique in 76 patients, in 22 patients an open reduction was necessary before screw insertion. 81 patients received a unilateral, 17 patients a bilateral screw osteosynthesis. 199 screws were inserted in S1, only eight screws in S2. 65 patients received two screws unilaterally, ten patients two screws bilaterally. There were no vascular or neurologic complications. During in-hospital stay, there were seven complications, which needed 12 operative revisions: three wound infections, two hematomas, one screw malalignment and one early screw loosening. In 28 patients with 56 iliosacral screws, a pelvic CT-scan was performed during follow-up. A penetration of a cortical layer was diagnosed in 20 of these screws. All penetrations were seen in double screw osteosynthesis of S1. In none of the patients, complaints could be explained by the malalignment of these screws. Five operative revisions were performed during follow-up: two for screw loosening, two for fracture healing problems and one for screw malalignment. Metal removal was performed in 39 patients with 75 screws. 2D-fluoroscopic-guided iliosacral screw osteosynthesis is a safe and efficient procedure in clinical practice. DISCUSSION: A thorough preoperative evaluation of the morphology of the upper sacrum and careful operative procedure are indispensable. Fluoroscopic views in AP, lateral, inlet and outlet must allow recognition of all anatomical landmarks. The indication for double screw osteosynthesis in S1 should be taken with caution. Screw malalignments do not inevitably correlate with complaints. Springer Berlin Heidelberg 2020-04-15 2021 /pmc/articles/PMC8629807/ /pubmed/32296862 http://dx.doi.org/10.1007/s00068-020-01362-9 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Rommens, Pol Maria
Nolte, Eva Mareike
Hopf, Johannes
Wagner, Daniel
Hofmann, Alexander
Hessmann, Martin
Safety and efficacy of 2D-fluoroscopy-based iliosacral screw osteosynthesis: results of a retrospective monocentric study
title Safety and efficacy of 2D-fluoroscopy-based iliosacral screw osteosynthesis: results of a retrospective monocentric study
title_full Safety and efficacy of 2D-fluoroscopy-based iliosacral screw osteosynthesis: results of a retrospective monocentric study
title_fullStr Safety and efficacy of 2D-fluoroscopy-based iliosacral screw osteosynthesis: results of a retrospective monocentric study
title_full_unstemmed Safety and efficacy of 2D-fluoroscopy-based iliosacral screw osteosynthesis: results of a retrospective monocentric study
title_short Safety and efficacy of 2D-fluoroscopy-based iliosacral screw osteosynthesis: results of a retrospective monocentric study
title_sort safety and efficacy of 2d-fluoroscopy-based iliosacral screw osteosynthesis: results of a retrospective monocentric study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8629807/
https://www.ncbi.nlm.nih.gov/pubmed/32296862
http://dx.doi.org/10.1007/s00068-020-01362-9
work_keys_str_mv AT rommenspolmaria safetyandefficacyof2dfluoroscopybasediliosacralscrewosteosynthesisresultsofaretrospectivemonocentricstudy
AT nolteevamareike safetyandefficacyof2dfluoroscopybasediliosacralscrewosteosynthesisresultsofaretrospectivemonocentricstudy
AT hopfjohannes safetyandefficacyof2dfluoroscopybasediliosacralscrewosteosynthesisresultsofaretrospectivemonocentricstudy
AT wagnerdaniel safetyandefficacyof2dfluoroscopybasediliosacralscrewosteosynthesisresultsofaretrospectivemonocentricstudy
AT hofmannalexander safetyandefficacyof2dfluoroscopybasediliosacralscrewosteosynthesisresultsofaretrospectivemonocentricstudy
AT hessmannmartin safetyandefficacyof2dfluoroscopybasediliosacralscrewosteosynthesisresultsofaretrospectivemonocentricstudy