Cargando…

Alimentary tract obstruction attributed to use of barbed suture for double tract reconstruction after robot-assisted proximal gastrectomy: a case report

BACKGROUND: Anastomotic stenosis following esophagojejunostomy reconstruction by the overlap method with absorbable barbed sutures occurs only rarely in patients who have undergone laparoscopic surgery. We report anastomotic stenosis by the overlap method that we attributed to the lack of tactile se...

Descripción completa

Detalles Bibliográficos
Autores principales: Fujimoto, Daisuke, Taniguchi, Keizo, Miura, Fumihiko, Kobayashi, Hirotoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8630912/
https://www.ncbi.nlm.nih.gov/pubmed/34844585
http://dx.doi.org/10.1186/s12893-021-01407-9
_version_ 1784607455805702144
author Fujimoto, Daisuke
Taniguchi, Keizo
Miura, Fumihiko
Kobayashi, Hirotoshi
author_facet Fujimoto, Daisuke
Taniguchi, Keizo
Miura, Fumihiko
Kobayashi, Hirotoshi
author_sort Fujimoto, Daisuke
collection PubMed
description BACKGROUND: Anastomotic stenosis following esophagojejunostomy reconstruction by the overlap method with absorbable barbed sutures occurs only rarely in patients who have undergone laparoscopic surgery. We report anastomotic stenosis by the overlap method that we attributed to the lack of tactile sensation during robot-assisted surgery. CASE PRESENTATION: An 83-year-old man underwent robot-assisted laparoscopic proximal gastrectomy and lymph node dissection at our hospital for treatment of gastric cancer. Double tract reconstruction followed with side-to-side esophagojejunostomy (overlap method) performed with an endoscopic linear stapler. On completion of the anastomosis, the enterotomy was closed under robotic assistance with absorbable barbed suture. Once solid foods were introduced, the patient had difficulty swallowing and felt as though his digestive tract was stopped up. When upper gastrointestinal endoscopy was performed, we found the anastomotic lumen to be coated with food residue. After rinsing off the residue with water, we could see barbed suture protruding into the anastomotic lumen that had become entangled upon itself, which explained how the food residue had accumulated. We cut the entangled suture under endoscopic visualization using a loop cutter. CONCLUSION: This case highlights a stricture caused by insufficiently tensioning barbed suture, which subsequently protruded into the anastomotic lumen and became entangled upon itself. We believe this occurrence was associated with the lack of tactile sensation in robot-assisted surgery.
format Online
Article
Text
id pubmed-8630912
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-86309122021-12-01 Alimentary tract obstruction attributed to use of barbed suture for double tract reconstruction after robot-assisted proximal gastrectomy: a case report Fujimoto, Daisuke Taniguchi, Keizo Miura, Fumihiko Kobayashi, Hirotoshi BMC Surg Case Report BACKGROUND: Anastomotic stenosis following esophagojejunostomy reconstruction by the overlap method with absorbable barbed sutures occurs only rarely in patients who have undergone laparoscopic surgery. We report anastomotic stenosis by the overlap method that we attributed to the lack of tactile sensation during robot-assisted surgery. CASE PRESENTATION: An 83-year-old man underwent robot-assisted laparoscopic proximal gastrectomy and lymph node dissection at our hospital for treatment of gastric cancer. Double tract reconstruction followed with side-to-side esophagojejunostomy (overlap method) performed with an endoscopic linear stapler. On completion of the anastomosis, the enterotomy was closed under robotic assistance with absorbable barbed suture. Once solid foods were introduced, the patient had difficulty swallowing and felt as though his digestive tract was stopped up. When upper gastrointestinal endoscopy was performed, we found the anastomotic lumen to be coated with food residue. After rinsing off the residue with water, we could see barbed suture protruding into the anastomotic lumen that had become entangled upon itself, which explained how the food residue had accumulated. We cut the entangled suture under endoscopic visualization using a loop cutter. CONCLUSION: This case highlights a stricture caused by insufficiently tensioning barbed suture, which subsequently protruded into the anastomotic lumen and became entangled upon itself. We believe this occurrence was associated with the lack of tactile sensation in robot-assisted surgery. BioMed Central 2021-11-29 /pmc/articles/PMC8630912/ /pubmed/34844585 http://dx.doi.org/10.1186/s12893-021-01407-9 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Case Report
Fujimoto, Daisuke
Taniguchi, Keizo
Miura, Fumihiko
Kobayashi, Hirotoshi
Alimentary tract obstruction attributed to use of barbed suture for double tract reconstruction after robot-assisted proximal gastrectomy: a case report
title Alimentary tract obstruction attributed to use of barbed suture for double tract reconstruction after robot-assisted proximal gastrectomy: a case report
title_full Alimentary tract obstruction attributed to use of barbed suture for double tract reconstruction after robot-assisted proximal gastrectomy: a case report
title_fullStr Alimentary tract obstruction attributed to use of barbed suture for double tract reconstruction after robot-assisted proximal gastrectomy: a case report
title_full_unstemmed Alimentary tract obstruction attributed to use of barbed suture for double tract reconstruction after robot-assisted proximal gastrectomy: a case report
title_short Alimentary tract obstruction attributed to use of barbed suture for double tract reconstruction after robot-assisted proximal gastrectomy: a case report
title_sort alimentary tract obstruction attributed to use of barbed suture for double tract reconstruction after robot-assisted proximal gastrectomy: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8630912/
https://www.ncbi.nlm.nih.gov/pubmed/34844585
http://dx.doi.org/10.1186/s12893-021-01407-9
work_keys_str_mv AT fujimotodaisuke alimentarytractobstructionattributedtouseofbarbedsuturefordoubletractreconstructionafterrobotassistedproximalgastrectomyacasereport
AT taniguchikeizo alimentarytractobstructionattributedtouseofbarbedsuturefordoubletractreconstructionafterrobotassistedproximalgastrectomyacasereport
AT miurafumihiko alimentarytractobstructionattributedtouseofbarbedsuturefordoubletractreconstructionafterrobotassistedproximalgastrectomyacasereport
AT kobayashihirotoshi alimentarytractobstructionattributedtouseofbarbedsuturefordoubletractreconstructionafterrobotassistedproximalgastrectomyacasereport