Cargando…

The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis

The purpose of this study was to compare the accuracy and the inter- and intra-observer reliability of preoperative digital 2D templating in prosthesis size prediction for the planning of cemented or uncemented THA. This study was registered in the NIHR PROSPERO database (ID: CRD42020216649) and con...

Descripción completa

Detalles Bibliográficos
Autores principales: Smith, Joshua B.V., Bishi, Habeeb, Wang, Chao, Asopa, Vipin, Field, Richard E., Sochart, David H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: British Editorial Society of Bone and Joint Surgery 2021
Materias:
Hip
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8631246/
https://www.ncbi.nlm.nih.gov/pubmed/34909222
http://dx.doi.org/10.1302/2058-5241.6.210048
_version_ 1784607515401519104
author Smith, Joshua B.V.
Bishi, Habeeb
Wang, Chao
Asopa, Vipin
Field, Richard E.
Sochart, David H.
author_facet Smith, Joshua B.V.
Bishi, Habeeb
Wang, Chao
Asopa, Vipin
Field, Richard E.
Sochart, David H.
author_sort Smith, Joshua B.V.
collection PubMed
description The purpose of this study was to compare the accuracy and the inter- and intra-observer reliability of preoperative digital 2D templating in prosthesis size prediction for the planning of cemented or uncemented THA. This study was registered in the NIHR PROSPERO database (ID: CRD42020216649) and conducted according to the PRISMA guidelines. A search of electronic databases in March 2021 found 29 papers overall. The quality of evidence was assessed using the IHE Quality Appraisal of Case Series Studies Checklist and the CASP Randomised Controlled Trials Checklist. A meta-analysis was conducted, and the accuracy was presented as proportions and the inter- and intra-observer reliability were measured using intraclass correlation coefficients (ICC). Accuracy within one prosthesis size (±1) for cemented stems was 0.89 (95% confidence interval (CI) 0.83–0.95), cemented cups 0.78 (95% CI 0.67–0.89), uncemented stems 0.74 (95% CI 0.66–0.82) and uncemented cups 0.73 (95% CI 0.67–0.79) (test of group differences: p = 0.010). Inter-observer reliability (ICC) for uncemented cups was 0.88 (95% CI 0.85–0.91), uncemented stems 0.86 (95% CI 0.81–0.91), cemented stems 0.69 (95% CI 0.54–0.84) and cemented cups 0.68 (95% CI 0.55–0.81) (test of group differences: p = 0.004). Due to lack of data, intra-observer reliability (ICC) could only be calculated for uncemented prostheses, which for the stems was 0.90 (95% CI 0.88–0.92) and for the cups was 0.87 (95% CI 0.83–0.90) (test of group differences: p = 0.124). The accuracy of preoperative digital templating is greater for cemented prostheses, but the inter-observer reliability is greater for uncemented prostheses. The intra-observer reliability showed a high level of agreement for uncemented prostheses. Cite this article: EFORT Open Rev 2021;6:1020-1039. DOI: 10.1302/2058-5241.6.210048
format Online
Article
Text
id pubmed-8631246
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher British Editorial Society of Bone and Joint Surgery
record_format MEDLINE/PubMed
spelling pubmed-86312462021-12-13 The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis Smith, Joshua B.V. Bishi, Habeeb Wang, Chao Asopa, Vipin Field, Richard E. Sochart, David H. EFORT Open Rev Hip The purpose of this study was to compare the accuracy and the inter- and intra-observer reliability of preoperative digital 2D templating in prosthesis size prediction for the planning of cemented or uncemented THA. This study was registered in the NIHR PROSPERO database (ID: CRD42020216649) and conducted according to the PRISMA guidelines. A search of electronic databases in March 2021 found 29 papers overall. The quality of evidence was assessed using the IHE Quality Appraisal of Case Series Studies Checklist and the CASP Randomised Controlled Trials Checklist. A meta-analysis was conducted, and the accuracy was presented as proportions and the inter- and intra-observer reliability were measured using intraclass correlation coefficients (ICC). Accuracy within one prosthesis size (±1) for cemented stems was 0.89 (95% confidence interval (CI) 0.83–0.95), cemented cups 0.78 (95% CI 0.67–0.89), uncemented stems 0.74 (95% CI 0.66–0.82) and uncemented cups 0.73 (95% CI 0.67–0.79) (test of group differences: p = 0.010). Inter-observer reliability (ICC) for uncemented cups was 0.88 (95% CI 0.85–0.91), uncemented stems 0.86 (95% CI 0.81–0.91), cemented stems 0.69 (95% CI 0.54–0.84) and cemented cups 0.68 (95% CI 0.55–0.81) (test of group differences: p = 0.004). Due to lack of data, intra-observer reliability (ICC) could only be calculated for uncemented prostheses, which for the stems was 0.90 (95% CI 0.88–0.92) and for the cups was 0.87 (95% CI 0.83–0.90) (test of group differences: p = 0.124). The accuracy of preoperative digital templating is greater for cemented prostheses, but the inter-observer reliability is greater for uncemented prostheses. The intra-observer reliability showed a high level of agreement for uncemented prostheses. Cite this article: EFORT Open Rev 2021;6:1020-1039. DOI: 10.1302/2058-5241.6.210048 British Editorial Society of Bone and Joint Surgery 2021-11-19 /pmc/articles/PMC8631246/ /pubmed/34909222 http://dx.doi.org/10.1302/2058-5241.6.210048 Text en © 2021 The author(s) https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-Non Commercial 4.0 International (CC BY-NC 4.0) licence (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed.
spellingShingle Hip
Smith, Joshua B.V.
Bishi, Habeeb
Wang, Chao
Asopa, Vipin
Field, Richard E.
Sochart, David H.
The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis
title The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis
title_full The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis
title_fullStr The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis
title_full_unstemmed The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis
title_short The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis
title_sort accuracy and reliability of preoperative digital 2d templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis
topic Hip
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8631246/
https://www.ncbi.nlm.nih.gov/pubmed/34909222
http://dx.doi.org/10.1302/2058-5241.6.210048
work_keys_str_mv AT smithjoshuabv theaccuracyandreliabilityofpreoperativedigital2dtemplatinginprosthesissizepredictioninuncementedversuscementedtotalhiparthroplastyasystematicreviewandmetaanalysis
AT bishihabeeb theaccuracyandreliabilityofpreoperativedigital2dtemplatinginprosthesissizepredictioninuncementedversuscementedtotalhiparthroplastyasystematicreviewandmetaanalysis
AT wangchao theaccuracyandreliabilityofpreoperativedigital2dtemplatinginprosthesissizepredictioninuncementedversuscementedtotalhiparthroplastyasystematicreviewandmetaanalysis
AT asopavipin theaccuracyandreliabilityofpreoperativedigital2dtemplatinginprosthesissizepredictioninuncementedversuscementedtotalhiparthroplastyasystematicreviewandmetaanalysis
AT fieldricharde theaccuracyandreliabilityofpreoperativedigital2dtemplatinginprosthesissizepredictioninuncementedversuscementedtotalhiparthroplastyasystematicreviewandmetaanalysis
AT sochartdavidh theaccuracyandreliabilityofpreoperativedigital2dtemplatinginprosthesissizepredictioninuncementedversuscementedtotalhiparthroplastyasystematicreviewandmetaanalysis
AT smithjoshuabv accuracyandreliabilityofpreoperativedigital2dtemplatinginprosthesissizepredictioninuncementedversuscementedtotalhiparthroplastyasystematicreviewandmetaanalysis
AT bishihabeeb accuracyandreliabilityofpreoperativedigital2dtemplatinginprosthesissizepredictioninuncementedversuscementedtotalhiparthroplastyasystematicreviewandmetaanalysis
AT wangchao accuracyandreliabilityofpreoperativedigital2dtemplatinginprosthesissizepredictioninuncementedversuscementedtotalhiparthroplastyasystematicreviewandmetaanalysis
AT asopavipin accuracyandreliabilityofpreoperativedigital2dtemplatinginprosthesissizepredictioninuncementedversuscementedtotalhiparthroplastyasystematicreviewandmetaanalysis
AT fieldricharde accuracyandreliabilityofpreoperativedigital2dtemplatinginprosthesissizepredictioninuncementedversuscementedtotalhiparthroplastyasystematicreviewandmetaanalysis
AT sochartdavidh accuracyandreliabilityofpreoperativedigital2dtemplatinginprosthesissizepredictioninuncementedversuscementedtotalhiparthroplastyasystematicreviewandmetaanalysis