Cargando…
A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer
Background: In this study, a modified technique of resectoscopic slicing with a common bipolar loop was introduced, which facilitated the complete removal of the submucous fibroid inside the uterine cavity without any novel equipment. Results: Compared with the classical technique, our modified proc...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8631289/ https://www.ncbi.nlm.nih.gov/pubmed/34859040 http://dx.doi.org/10.3389/fsurg.2021.746936 |
_version_ | 1784607527643643904 |
---|---|
author | Zhang, Wenying Liu, Jing Wu, Qiongwei Liu, Yu Wang, Chunchun Ma, Chengbin |
author_facet | Zhang, Wenying Liu, Jing Wu, Qiongwei Liu, Yu Wang, Chunchun Ma, Chengbin |
author_sort | Zhang, Wenying |
collection | PubMed |
description | Background: In this study, a modified technique of resectoscopic slicing with a common bipolar loop was introduced, which facilitated the complete removal of the submucous fibroid inside the uterine cavity without any novel equipment. Results: Compared with the classical technique, our modified procedure possessed a shorter operation time (22.9 ± 7.3 vs. 38.9 ± 13.0 min, p < 0.05) and a smaller distending media volume (1,495.6 ± 540.1 vs. 2,393.1 ± 719.4 ml, p < 0.01). Conclusion: As a result, the current study suggested that the enucleation of submucous fibroid under hysteroscopy could be achieved by using only the bipolar loop, which reduced the consumption for novel equipment and enhanced the safety of the technique. |
format | Online Article Text |
id | pubmed-8631289 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-86312892021-12-01 A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer Zhang, Wenying Liu, Jing Wu, Qiongwei Liu, Yu Wang, Chunchun Ma, Chengbin Front Surg Surgery Background: In this study, a modified technique of resectoscopic slicing with a common bipolar loop was introduced, which facilitated the complete removal of the submucous fibroid inside the uterine cavity without any novel equipment. Results: Compared with the classical technique, our modified procedure possessed a shorter operation time (22.9 ± 7.3 vs. 38.9 ± 13.0 min, p < 0.05) and a smaller distending media volume (1,495.6 ± 540.1 vs. 2,393.1 ± 719.4 ml, p < 0.01). Conclusion: As a result, the current study suggested that the enucleation of submucous fibroid under hysteroscopy could be achieved by using only the bipolar loop, which reduced the consumption for novel equipment and enhanced the safety of the technique. Frontiers Media S.A. 2021-11-10 /pmc/articles/PMC8631289/ /pubmed/34859040 http://dx.doi.org/10.3389/fsurg.2021.746936 Text en Copyright © 2021 Zhang, Liu, Wu, Liu, Wang and Ma. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Surgery Zhang, Wenying Liu, Jing Wu, Qiongwei Liu, Yu Wang, Chunchun Ma, Chengbin A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer |
title | A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer |
title_full | A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer |
title_fullStr | A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer |
title_full_unstemmed | A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer |
title_short | A Modified Technique of Bipolar Loop Resectoscopic Slicing for Treating Submucous Fibroids With Enucleation Makes the Operation Safer |
title_sort | modified technique of bipolar loop resectoscopic slicing for treating submucous fibroids with enucleation makes the operation safer |
topic | Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8631289/ https://www.ncbi.nlm.nih.gov/pubmed/34859040 http://dx.doi.org/10.3389/fsurg.2021.746936 |
work_keys_str_mv | AT zhangwenying amodifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT liujing amodifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT wuqiongwei amodifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT liuyu amodifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT wangchunchun amodifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT machengbin amodifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT zhangwenying modifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT liujing modifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT wuqiongwei modifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT liuyu modifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT wangchunchun modifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer AT machengbin modifiedtechniqueofbipolarloopresectoscopicslicingfortreatingsubmucousfibroidswithenucleationmakestheoperationsafer |