Cargando…
Optimizing ECG to detect echocardiographic left ventricular hypertrophy with computer-based ECG data and machine learning
BACKGROUND: Left ventricular hypertrophy detected by echocardiography (Echo-LVH) is an independent predictor of mortality. Integration of the Philips DXL-16 algorithm into the electrocardiogram (ECG) extensively analyses the electricity of the heart. Machine learning techniques such as the C5.0 coul...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8631676/ https://www.ncbi.nlm.nih.gov/pubmed/34847202 http://dx.doi.org/10.1371/journal.pone.0260661 |
Sumario: | BACKGROUND: Left ventricular hypertrophy detected by echocardiography (Echo-LVH) is an independent predictor of mortality. Integration of the Philips DXL-16 algorithm into the electrocardiogram (ECG) extensively analyses the electricity of the heart. Machine learning techniques such as the C5.0 could lead to a new decision tree criterion to detect Echo-LVH. OBJECTIVES: To search for a new combination of ECG parameters predictive of Echo-LVH. The final model is called the Cardiac Hypertrophy Computer-based model (CHCM). METHODS: We extracted the 458 ECG parameters provided by the Philips DXL-16 algorithm in patients with Echo-LVH and controls. We used the C5.0 ML algorithm to train, test, and validate the CHCM. We compared its diagnostic performance to validate state-of-the-art criteria in our patient cohort. RESULTS: We included 439 patients and considered an alpha value of 0.05 and a power of 99%. The CHCM includes T voltage in I (≤0.055 mV), peak-to-peak QRS distance in aVL (>1.235 mV), and peak-to-peak QRS distance in aVF (>0.178 mV). The CHCM had an accuracy of 70.5% (CI95%, 65.2–75.5), a sensitivity of 74.3%, and a specificity of 68.7%. In the external validation cohort (n = 156), the CHCM had an accuracy of 63.5% (CI95%, 55.4–71), a sensitivity of 42%, and a specificity of 82.9%. The accuracies of the most relevant state-of-the-art criteria were: Romhilt-Estes (57.4%, CI95% 49–65.5), VDP Cornell (55.7%, CI95%47.6–63.7), Cornell (59%, CI95%50.8–66.8), Dalfó (62.9%, CI95%54.7–70.6), Sokolow Lyon (53.9%, CI95%45.7–61.9), and Philips DXL-16 algorithm (54.5%, CI95%46.3–62.5). CONCLUSION: ECG computer-based data and the C5.0 determined a new set of ECG parameters to predict Echo-LVH. The CHCM classifies patients as Echo-LVH with repolarization abnormalities or LVH with increased voltage. The CHCM has a similar accuracy, and is slightly more sensitive than the state-of-the-art criteria. |
---|