Cargando…

Application of Multislice Spiral CT Imaging Technology in the Diagnosis of Patients with Chest Sarcoidosis

OBJECTIVE: To study the qualitative value of multislice spiral CT (MSCT) dynamic enhancement scanning for solitary nodules (SPN) of the chest. METHODS: In this paper, 40 cases of chest nodules (including 25 cases of malignant nodules, 8 cases of inflammatory nodules, and 7 cases of benign nodules) w...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Hong-Fei, Chen, Liang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8632395/
https://www.ncbi.nlm.nih.gov/pubmed/34858562
http://dx.doi.org/10.1155/2021/2887639
_version_ 1784607747000500224
author Ma, Hong-Fei
Chen, Liang
author_facet Ma, Hong-Fei
Chen, Liang
author_sort Ma, Hong-Fei
collection PubMed
description OBJECTIVE: To study the qualitative value of multislice spiral CT (MSCT) dynamic enhancement scanning for solitary nodules (SPN) of the chest. METHODS: In this paper, 40 cases of chest nodules (including 25 cases of malignant nodules, 8 cases of inflammatory nodules, and 7 cases of benign nodules) were first scanned to determine the scope of nodules. At the two rates of 5 ml/s and 3 ml/s, CT dynamic enhancement scans were performed at the center of the nodule, and the CT values, peak enhancement (PH) and peak time (PT) before and after SPN enhancement, were recorded. It is mainly strengthened, with 80% (20/25) of net added value between 20 and 60 Hu, and 20% (5/25) >60 Hu or <20 Hu. The enhancement peak and peak time are (31.31 ± 10.62) Hu and 45 s, respectively. The time-density curve (T-DC) showed a slowly rising type; the inflammatory nodules were mainly severely strengthened, with a net increase of >40 Hu. The enhancement peak value is (49.25 ± 12.44) Hu, and the peak time is 80 s and 140 s. There is a characteristic of rising and falling and then rising in the curve. CONCLUSION: Multislice spiral CT dynamic enhancement scan reflects the dynamic characteristics of chest nodular blood flow, which can be used to noninvasively evaluate and diagnose SPN.
format Online
Article
Text
id pubmed-8632395
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-86323952021-12-01 Application of Multislice Spiral CT Imaging Technology in the Diagnosis of Patients with Chest Sarcoidosis Ma, Hong-Fei Chen, Liang J Healthc Eng Research Article OBJECTIVE: To study the qualitative value of multislice spiral CT (MSCT) dynamic enhancement scanning for solitary nodules (SPN) of the chest. METHODS: In this paper, 40 cases of chest nodules (including 25 cases of malignant nodules, 8 cases of inflammatory nodules, and 7 cases of benign nodules) were first scanned to determine the scope of nodules. At the two rates of 5 ml/s and 3 ml/s, CT dynamic enhancement scans were performed at the center of the nodule, and the CT values, peak enhancement (PH) and peak time (PT) before and after SPN enhancement, were recorded. It is mainly strengthened, with 80% (20/25) of net added value between 20 and 60 Hu, and 20% (5/25) >60 Hu or <20 Hu. The enhancement peak and peak time are (31.31 ± 10.62) Hu and 45 s, respectively. The time-density curve (T-DC) showed a slowly rising type; the inflammatory nodules were mainly severely strengthened, with a net increase of >40 Hu. The enhancement peak value is (49.25 ± 12.44) Hu, and the peak time is 80 s and 140 s. There is a characteristic of rising and falling and then rising in the curve. CONCLUSION: Multislice spiral CT dynamic enhancement scan reflects the dynamic characteristics of chest nodular blood flow, which can be used to noninvasively evaluate and diagnose SPN. Hindawi 2021-11-23 /pmc/articles/PMC8632395/ /pubmed/34858562 http://dx.doi.org/10.1155/2021/2887639 Text en Copyright © 2021 Hong-Fei Ma and Liang Chen. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ma, Hong-Fei
Chen, Liang
Application of Multislice Spiral CT Imaging Technology in the Diagnosis of Patients with Chest Sarcoidosis
title Application of Multislice Spiral CT Imaging Technology in the Diagnosis of Patients with Chest Sarcoidosis
title_full Application of Multislice Spiral CT Imaging Technology in the Diagnosis of Patients with Chest Sarcoidosis
title_fullStr Application of Multislice Spiral CT Imaging Technology in the Diagnosis of Patients with Chest Sarcoidosis
title_full_unstemmed Application of Multislice Spiral CT Imaging Technology in the Diagnosis of Patients with Chest Sarcoidosis
title_short Application of Multislice Spiral CT Imaging Technology in the Diagnosis of Patients with Chest Sarcoidosis
title_sort application of multislice spiral ct imaging technology in the diagnosis of patients with chest sarcoidosis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8632395/
https://www.ncbi.nlm.nih.gov/pubmed/34858562
http://dx.doi.org/10.1155/2021/2887639
work_keys_str_mv AT mahongfei applicationofmultislicespiralctimagingtechnologyinthediagnosisofpatientswithchestsarcoidosis
AT chenliang applicationofmultislicespiralctimagingtechnologyinthediagnosisofpatientswithchestsarcoidosis