Comparison of the New Viscoelastic Coagulation Analyzer ClotPro® With ROTEM® Delta and Conventional Coagulation Tests in Critically Ill Patients With COVID-19
Background: Viscoelastic coagulation testing has been suggested to help manage coagulopathy in critically ill patients with COVID-19. However, results from different viscoelastic devices are not readily comparable. ClotPro® is a novel thromboelastometry analyzer offering a wider range of commerciall...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8635118/ https://www.ncbi.nlm.nih.gov/pubmed/34869496 http://dx.doi.org/10.3389/fmed.2021.777145 |
_version_ | 1784608238914764800 |
---|---|
author | Infanger, Lukas Dibiasi, Christoph Schaden, Eva Ulbing, Stefan Wiegele, Marion Lacom, Conrad Gratz, Johannes |
author_facet | Infanger, Lukas Dibiasi, Christoph Schaden, Eva Ulbing, Stefan Wiegele, Marion Lacom, Conrad Gratz, Johannes |
author_sort | Infanger, Lukas |
collection | PubMed |
description | Background: Viscoelastic coagulation testing has been suggested to help manage coagulopathy in critically ill patients with COVID-19. However, results from different viscoelastic devices are not readily comparable. ClotPro® is a novel thromboelastometry analyzer offering a wider range of commercially available assays. Methods: We compared the results from ClotPro with results from the well-established ROTEM® Delta device and conventional coagulation tests in critically ill patients with COVID-19. Results: Viscoelastic parameters indicated the presence of a potentially hypercoagulable state in the majority of patients. In up to 95 paired measurements, we found strong correlations between several parameters routinely used in clinical practice: (i) EX test vs. EXTEM CT, A5, A10, MCF, (ii) IN test vs. INTEM A5, A10, MCF, and (iii) FIB test vs. FIBTEM A5, A10, MCF (all R > 0.7 and p < 0.001). In contrast, IN test CT vs. INTEM CT showed only a moderate correlation (R = 0.53 and p < 0.001). Clot strength parameters of both devices exhibited strong correlations with platelet counts and fibrinogen levels (all R > 0.7 and p < 0.001). Divergent correlations of intrinsically activated assays with aPTT and anti-factor Xa activity were visible. Regarding absolute differences of test results, considerable delta occurred in CT, CFT, and clot strength parameters (all p < 0.001) between both devices. Conclusions: Several parameters obtained by ClotPro show strong correlations with ROTEM Delta. Due to weak correlations of intrinsically activated clotting times and considerable absolute differences in a number of parameters, our findings underline the need for device-specific algorithms in this patient cohort. |
format | Online Article Text |
id | pubmed-8635118 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-86351182021-12-02 Comparison of the New Viscoelastic Coagulation Analyzer ClotPro® With ROTEM® Delta and Conventional Coagulation Tests in Critically Ill Patients With COVID-19 Infanger, Lukas Dibiasi, Christoph Schaden, Eva Ulbing, Stefan Wiegele, Marion Lacom, Conrad Gratz, Johannes Front Med (Lausanne) Medicine Background: Viscoelastic coagulation testing has been suggested to help manage coagulopathy in critically ill patients with COVID-19. However, results from different viscoelastic devices are not readily comparable. ClotPro® is a novel thromboelastometry analyzer offering a wider range of commercially available assays. Methods: We compared the results from ClotPro with results from the well-established ROTEM® Delta device and conventional coagulation tests in critically ill patients with COVID-19. Results: Viscoelastic parameters indicated the presence of a potentially hypercoagulable state in the majority of patients. In up to 95 paired measurements, we found strong correlations between several parameters routinely used in clinical practice: (i) EX test vs. EXTEM CT, A5, A10, MCF, (ii) IN test vs. INTEM A5, A10, MCF, and (iii) FIB test vs. FIBTEM A5, A10, MCF (all R > 0.7 and p < 0.001). In contrast, IN test CT vs. INTEM CT showed only a moderate correlation (R = 0.53 and p < 0.001). Clot strength parameters of both devices exhibited strong correlations with platelet counts and fibrinogen levels (all R > 0.7 and p < 0.001). Divergent correlations of intrinsically activated assays with aPTT and anti-factor Xa activity were visible. Regarding absolute differences of test results, considerable delta occurred in CT, CFT, and clot strength parameters (all p < 0.001) between both devices. Conclusions: Several parameters obtained by ClotPro show strong correlations with ROTEM Delta. Due to weak correlations of intrinsically activated clotting times and considerable absolute differences in a number of parameters, our findings underline the need for device-specific algorithms in this patient cohort. Frontiers Media S.A. 2021-11-16 /pmc/articles/PMC8635118/ /pubmed/34869496 http://dx.doi.org/10.3389/fmed.2021.777145 Text en Copyright © 2021 Infanger, Dibiasi, Schaden, Ulbing, Wiegele, Lacom and Gratz. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Infanger, Lukas Dibiasi, Christoph Schaden, Eva Ulbing, Stefan Wiegele, Marion Lacom, Conrad Gratz, Johannes Comparison of the New Viscoelastic Coagulation Analyzer ClotPro® With ROTEM® Delta and Conventional Coagulation Tests in Critically Ill Patients With COVID-19 |
title | Comparison of the New Viscoelastic Coagulation Analyzer ClotPro® With ROTEM® Delta and Conventional Coagulation Tests in Critically Ill Patients With COVID-19 |
title_full | Comparison of the New Viscoelastic Coagulation Analyzer ClotPro® With ROTEM® Delta and Conventional Coagulation Tests in Critically Ill Patients With COVID-19 |
title_fullStr | Comparison of the New Viscoelastic Coagulation Analyzer ClotPro® With ROTEM® Delta and Conventional Coagulation Tests in Critically Ill Patients With COVID-19 |
title_full_unstemmed | Comparison of the New Viscoelastic Coagulation Analyzer ClotPro® With ROTEM® Delta and Conventional Coagulation Tests in Critically Ill Patients With COVID-19 |
title_short | Comparison of the New Viscoelastic Coagulation Analyzer ClotPro® With ROTEM® Delta and Conventional Coagulation Tests in Critically Ill Patients With COVID-19 |
title_sort | comparison of the new viscoelastic coagulation analyzer clotpro® with rotem® delta and conventional coagulation tests in critically ill patients with covid-19 |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8635118/ https://www.ncbi.nlm.nih.gov/pubmed/34869496 http://dx.doi.org/10.3389/fmed.2021.777145 |
work_keys_str_mv | AT infangerlukas comparisonofthenewviscoelasticcoagulationanalyzerclotprowithrotemdeltaandconventionalcoagulationtestsincriticallyillpatientswithcovid19 AT dibiasichristoph comparisonofthenewviscoelasticcoagulationanalyzerclotprowithrotemdeltaandconventionalcoagulationtestsincriticallyillpatientswithcovid19 AT schadeneva comparisonofthenewviscoelasticcoagulationanalyzerclotprowithrotemdeltaandconventionalcoagulationtestsincriticallyillpatientswithcovid19 AT ulbingstefan comparisonofthenewviscoelasticcoagulationanalyzerclotprowithrotemdeltaandconventionalcoagulationtestsincriticallyillpatientswithcovid19 AT wiegelemarion comparisonofthenewviscoelasticcoagulationanalyzerclotprowithrotemdeltaandconventionalcoagulationtestsincriticallyillpatientswithcovid19 AT lacomconrad comparisonofthenewviscoelasticcoagulationanalyzerclotprowithrotemdeltaandconventionalcoagulationtestsincriticallyillpatientswithcovid19 AT gratzjohannes comparisonofthenewviscoelasticcoagulationanalyzerclotprowithrotemdeltaandconventionalcoagulationtestsincriticallyillpatientswithcovid19 |