Cargando…

The reliability of the angle of deviation measurement from the Photo-Hirschberg tests and Krimsky tests

OBJECTIVE: To compare the angle of deviation measured from Photo-Hirschberg testing and Krimsky testing, with that from an alternate prism cover test (APCT) in strabismus patients. METHODS: A cross-sectional study was conducted in Songklanagarind Hospital, Thailand. Thirty-three strabismus patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Tengtrisorn, S., Tungsattayathitthan, A., Na Phatthalung, S., Singha, P., Rattanalert, N., Bhurachokviwat, S., Chouyjan, S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8635364/
https://www.ncbi.nlm.nih.gov/pubmed/34851974
http://dx.doi.org/10.1371/journal.pone.0258744
_version_ 1784608287069569024
author Tengtrisorn, S.
Tungsattayathitthan, A.
Na Phatthalung, S.
Singha, P.
Rattanalert, N.
Bhurachokviwat, S.
Chouyjan, S.
author_facet Tengtrisorn, S.
Tungsattayathitthan, A.
Na Phatthalung, S.
Singha, P.
Rattanalert, N.
Bhurachokviwat, S.
Chouyjan, S.
author_sort Tengtrisorn, S.
collection PubMed
description OBJECTIVE: To compare the angle of deviation measured from Photo-Hirschberg testing and Krimsky testing, with that from an alternate prism cover test (APCT) in strabismus patients. METHODS: A cross-sectional study was conducted in Songklanagarind Hospital, Thailand. Thirty-three strabismus patients were photographed for analysis by Photo-Hirschberg testing using computer software. The corneal light reflex displacement, converted into prism diopter (PD), was compared to the angle of deviation measured with APCT. Twenty-eight strabismus patients were tested with the Krimsky test. Data were analyzed using Pearson correlation and paired t-tests. The study excluded 4 intermittent exotropia cases, 1 intermittent esotropia case and 2 which cases missing data for krimsky test. RESULTS: The mean±SD of the deviation angle, measured by APCT with a fixation target at 30 cm and 6 m; were 48.09±16.34PD and 47.82±15.73 PD, respectively. At 1 m, the difference in the angle of deviation measured from APCT and the Photo-Hirschberg test within 10 PD were 58.8% and 63.6%, for ET and XT, respectively. The difference in the angle of deviation measured from APCT and Krimsky tests within 10 PD in ET and XT were 86.7% and 80.0%, respectively. At 4 m, the difference in angle of deviation measured from APCT and Photo-Hirschberg tests within 10 PD in ET and XT were 58.8% and 54.5%, respectively; whereas, the difference in the angle of deviation measured from APCT and Krimsky tests within 10 PD in ET and XT were 80.0% and 70.0%, respectively. CONCLUSION: The reliability of Krimsky test was better than Photo-Hirschberg test for measuring an angle of deviation.
format Online
Article
Text
id pubmed-8635364
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-86353642021-12-02 The reliability of the angle of deviation measurement from the Photo-Hirschberg tests and Krimsky tests Tengtrisorn, S. Tungsattayathitthan, A. Na Phatthalung, S. Singha, P. Rattanalert, N. Bhurachokviwat, S. Chouyjan, S. PLoS One Research Article OBJECTIVE: To compare the angle of deviation measured from Photo-Hirschberg testing and Krimsky testing, with that from an alternate prism cover test (APCT) in strabismus patients. METHODS: A cross-sectional study was conducted in Songklanagarind Hospital, Thailand. Thirty-three strabismus patients were photographed for analysis by Photo-Hirschberg testing using computer software. The corneal light reflex displacement, converted into prism diopter (PD), was compared to the angle of deviation measured with APCT. Twenty-eight strabismus patients were tested with the Krimsky test. Data were analyzed using Pearson correlation and paired t-tests. The study excluded 4 intermittent exotropia cases, 1 intermittent esotropia case and 2 which cases missing data for krimsky test. RESULTS: The mean±SD of the deviation angle, measured by APCT with a fixation target at 30 cm and 6 m; were 48.09±16.34PD and 47.82±15.73 PD, respectively. At 1 m, the difference in the angle of deviation measured from APCT and the Photo-Hirschberg test within 10 PD were 58.8% and 63.6%, for ET and XT, respectively. The difference in the angle of deviation measured from APCT and Krimsky tests within 10 PD in ET and XT were 86.7% and 80.0%, respectively. At 4 m, the difference in angle of deviation measured from APCT and Photo-Hirschberg tests within 10 PD in ET and XT were 58.8% and 54.5%, respectively; whereas, the difference in the angle of deviation measured from APCT and Krimsky tests within 10 PD in ET and XT were 80.0% and 70.0%, respectively. CONCLUSION: The reliability of Krimsky test was better than Photo-Hirschberg test for measuring an angle of deviation. Public Library of Science 2021-12-01 /pmc/articles/PMC8635364/ /pubmed/34851974 http://dx.doi.org/10.1371/journal.pone.0258744 Text en © 2021 Tengtrisorn et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Tengtrisorn, S.
Tungsattayathitthan, A.
Na Phatthalung, S.
Singha, P.
Rattanalert, N.
Bhurachokviwat, S.
Chouyjan, S.
The reliability of the angle of deviation measurement from the Photo-Hirschberg tests and Krimsky tests
title The reliability of the angle of deviation measurement from the Photo-Hirschberg tests and Krimsky tests
title_full The reliability of the angle of deviation measurement from the Photo-Hirschberg tests and Krimsky tests
title_fullStr The reliability of the angle of deviation measurement from the Photo-Hirschberg tests and Krimsky tests
title_full_unstemmed The reliability of the angle of deviation measurement from the Photo-Hirschberg tests and Krimsky tests
title_short The reliability of the angle of deviation measurement from the Photo-Hirschberg tests and Krimsky tests
title_sort reliability of the angle of deviation measurement from the photo-hirschberg tests and krimsky tests
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8635364/
https://www.ncbi.nlm.nih.gov/pubmed/34851974
http://dx.doi.org/10.1371/journal.pone.0258744
work_keys_str_mv AT tengtrisorns thereliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests
AT tungsattayathitthana thereliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests
AT naphatthalungs thereliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests
AT singhap thereliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests
AT rattanalertn thereliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests
AT bhurachokviwats thereliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests
AT chouyjans thereliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests
AT tengtrisorns reliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests
AT tungsattayathitthana reliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests
AT naphatthalungs reliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests
AT singhap reliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests
AT rattanalertn reliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests
AT bhurachokviwats reliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests
AT chouyjans reliabilityoftheangleofdeviationmeasurementfromthephotohirschbergtestsandkrimskytests