Cargando…

Diagnostic Performance of 2D and 3D T2WI-Based Radiomics Features With Machine Learning Algorithms to Distinguish Solid Solitary Pulmonary Lesion

OBJECTIVE: To evaluate the performance of 2D and 3D radiomics features with different machine learning approaches to classify SPLs based on magnetic resonance(MR) T2 weighted imaging (T2WI). MATERIAL AND METHODS: A total of 132 patients with pathologically confirmed SPLs were examined and randomly d...

Descripción completa

Detalles Bibliográficos
Autores principales: Wan, Qi, Zhou, Jiaxuan, Xia, Xiaoying, Hu, Jianfeng, Wang, Peng, Peng, Yu, Zhang, Tianjing, Sun, Jianqing, Song, Yang, Yang, Guang, Li, Xinchun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8637439/
https://www.ncbi.nlm.nih.gov/pubmed/34868905
http://dx.doi.org/10.3389/fonc.2021.683587
_version_ 1784608741186863104
author Wan, Qi
Zhou, Jiaxuan
Xia, Xiaoying
Hu, Jianfeng
Wang, Peng
Peng, Yu
Zhang, Tianjing
Sun, Jianqing
Song, Yang
Yang, Guang
Li, Xinchun
author_facet Wan, Qi
Zhou, Jiaxuan
Xia, Xiaoying
Hu, Jianfeng
Wang, Peng
Peng, Yu
Zhang, Tianjing
Sun, Jianqing
Song, Yang
Yang, Guang
Li, Xinchun
author_sort Wan, Qi
collection PubMed
description OBJECTIVE: To evaluate the performance of 2D and 3D radiomics features with different machine learning approaches to classify SPLs based on magnetic resonance(MR) T2 weighted imaging (T2WI). MATERIAL AND METHODS: A total of 132 patients with pathologically confirmed SPLs were examined and randomly divided into training (n = 92) and test datasets (n = 40). A total of 1692 3D and 1231 2D radiomics features per patient were extracted. Both radiomics features and clinical data were evaluated. A total of 1260 classification models, comprising 3 normalization methods, 2 dimension reduction algorithms, 3 feature selection methods, and 10 classifiers with 7 different feature numbers (confined to 3–9), were compared. The ten-fold cross-validation on the training dataset was applied to choose the candidate final model. The area under the receiver operating characteristic curve (AUC), precision-recall plot, and Matthews Correlation Coefficient were used to evaluate the performance of machine learning approaches. RESULTS: The 3D features were significantly superior to 2D features, showing much more machine learning combinations with AUC greater than 0.7 in both validation and test groups (129 vs. 11). The feature selection method Analysis of Variance(ANOVA), Recursive Feature Elimination(RFE) and the classifier Logistic Regression(LR), Linear Discriminant Analysis(LDA), Support Vector Machine(SVM), Gaussian Process(GP) had relatively better performance. The best performance of 3D radiomics features in the test dataset (AUC = 0.824, AUC-PR = 0.927, MCC = 0.514) was higher than that of 2D features (AUC = 0.740, AUC-PR = 0.846, MCC = 0.404). The joint 3D and 2D features (AUC=0.813, AUC-PR = 0.926, MCC = 0.563) showed similar results as 3D features. Incorporating clinical features with 3D and 2D radiomics features slightly improved the AUC to 0.836 (AUC-PR = 0.918, MCC = 0.620) and 0.780 (AUC-PR = 0.900, MCC = 0.574), respectively. CONCLUSIONS: After algorithm optimization, 2D feature-based radiomics models yield favorable results in differentiating malignant and benign SPLs, but 3D features are still preferred because of the availability of more machine learning algorithmic combinations with better performance. Feature selection methods ANOVA and RFE, and classifier LR, LDA, SVM and GP are more likely to demonstrate better diagnostic performance for 3D features in the current study.
format Online
Article
Text
id pubmed-8637439
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-86374392021-12-03 Diagnostic Performance of 2D and 3D T2WI-Based Radiomics Features With Machine Learning Algorithms to Distinguish Solid Solitary Pulmonary Lesion Wan, Qi Zhou, Jiaxuan Xia, Xiaoying Hu, Jianfeng Wang, Peng Peng, Yu Zhang, Tianjing Sun, Jianqing Song, Yang Yang, Guang Li, Xinchun Front Oncol Oncology OBJECTIVE: To evaluate the performance of 2D and 3D radiomics features with different machine learning approaches to classify SPLs based on magnetic resonance(MR) T2 weighted imaging (T2WI). MATERIAL AND METHODS: A total of 132 patients with pathologically confirmed SPLs were examined and randomly divided into training (n = 92) and test datasets (n = 40). A total of 1692 3D and 1231 2D radiomics features per patient were extracted. Both radiomics features and clinical data were evaluated. A total of 1260 classification models, comprising 3 normalization methods, 2 dimension reduction algorithms, 3 feature selection methods, and 10 classifiers with 7 different feature numbers (confined to 3–9), were compared. The ten-fold cross-validation on the training dataset was applied to choose the candidate final model. The area under the receiver operating characteristic curve (AUC), precision-recall plot, and Matthews Correlation Coefficient were used to evaluate the performance of machine learning approaches. RESULTS: The 3D features were significantly superior to 2D features, showing much more machine learning combinations with AUC greater than 0.7 in both validation and test groups (129 vs. 11). The feature selection method Analysis of Variance(ANOVA), Recursive Feature Elimination(RFE) and the classifier Logistic Regression(LR), Linear Discriminant Analysis(LDA), Support Vector Machine(SVM), Gaussian Process(GP) had relatively better performance. The best performance of 3D radiomics features in the test dataset (AUC = 0.824, AUC-PR = 0.927, MCC = 0.514) was higher than that of 2D features (AUC = 0.740, AUC-PR = 0.846, MCC = 0.404). The joint 3D and 2D features (AUC=0.813, AUC-PR = 0.926, MCC = 0.563) showed similar results as 3D features. Incorporating clinical features with 3D and 2D radiomics features slightly improved the AUC to 0.836 (AUC-PR = 0.918, MCC = 0.620) and 0.780 (AUC-PR = 0.900, MCC = 0.574), respectively. CONCLUSIONS: After algorithm optimization, 2D feature-based radiomics models yield favorable results in differentiating malignant and benign SPLs, but 3D features are still preferred because of the availability of more machine learning algorithmic combinations with better performance. Feature selection methods ANOVA and RFE, and classifier LR, LDA, SVM and GP are more likely to demonstrate better diagnostic performance for 3D features in the current study. Frontiers Media S.A. 2021-11-18 /pmc/articles/PMC8637439/ /pubmed/34868905 http://dx.doi.org/10.3389/fonc.2021.683587 Text en Copyright © 2021 Wan, Zhou, Xia, Hu, Wang, Peng, Zhang, Sun, Song, Yang and Li https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Wan, Qi
Zhou, Jiaxuan
Xia, Xiaoying
Hu, Jianfeng
Wang, Peng
Peng, Yu
Zhang, Tianjing
Sun, Jianqing
Song, Yang
Yang, Guang
Li, Xinchun
Diagnostic Performance of 2D and 3D T2WI-Based Radiomics Features With Machine Learning Algorithms to Distinguish Solid Solitary Pulmonary Lesion
title Diagnostic Performance of 2D and 3D T2WI-Based Radiomics Features With Machine Learning Algorithms to Distinguish Solid Solitary Pulmonary Lesion
title_full Diagnostic Performance of 2D and 3D T2WI-Based Radiomics Features With Machine Learning Algorithms to Distinguish Solid Solitary Pulmonary Lesion
title_fullStr Diagnostic Performance of 2D and 3D T2WI-Based Radiomics Features With Machine Learning Algorithms to Distinguish Solid Solitary Pulmonary Lesion
title_full_unstemmed Diagnostic Performance of 2D and 3D T2WI-Based Radiomics Features With Machine Learning Algorithms to Distinguish Solid Solitary Pulmonary Lesion
title_short Diagnostic Performance of 2D and 3D T2WI-Based Radiomics Features With Machine Learning Algorithms to Distinguish Solid Solitary Pulmonary Lesion
title_sort diagnostic performance of 2d and 3d t2wi-based radiomics features with machine learning algorithms to distinguish solid solitary pulmonary lesion
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8637439/
https://www.ncbi.nlm.nih.gov/pubmed/34868905
http://dx.doi.org/10.3389/fonc.2021.683587
work_keys_str_mv AT wanqi diagnosticperformanceof2dand3dt2wibasedradiomicsfeatureswithmachinelearningalgorithmstodistinguishsolidsolitarypulmonarylesion
AT zhoujiaxuan diagnosticperformanceof2dand3dt2wibasedradiomicsfeatureswithmachinelearningalgorithmstodistinguishsolidsolitarypulmonarylesion
AT xiaxiaoying diagnosticperformanceof2dand3dt2wibasedradiomicsfeatureswithmachinelearningalgorithmstodistinguishsolidsolitarypulmonarylesion
AT hujianfeng diagnosticperformanceof2dand3dt2wibasedradiomicsfeatureswithmachinelearningalgorithmstodistinguishsolidsolitarypulmonarylesion
AT wangpeng diagnosticperformanceof2dand3dt2wibasedradiomicsfeatureswithmachinelearningalgorithmstodistinguishsolidsolitarypulmonarylesion
AT pengyu diagnosticperformanceof2dand3dt2wibasedradiomicsfeatureswithmachinelearningalgorithmstodistinguishsolidsolitarypulmonarylesion
AT zhangtianjing diagnosticperformanceof2dand3dt2wibasedradiomicsfeatureswithmachinelearningalgorithmstodistinguishsolidsolitarypulmonarylesion
AT sunjianqing diagnosticperformanceof2dand3dt2wibasedradiomicsfeatureswithmachinelearningalgorithmstodistinguishsolidsolitarypulmonarylesion
AT songyang diagnosticperformanceof2dand3dt2wibasedradiomicsfeatureswithmachinelearningalgorithmstodistinguishsolidsolitarypulmonarylesion
AT yangguang diagnosticperformanceof2dand3dt2wibasedradiomicsfeatureswithmachinelearningalgorithmstodistinguishsolidsolitarypulmonarylesion
AT lixinchun diagnosticperformanceof2dand3dt2wibasedradiomicsfeatureswithmachinelearningalgorithmstodistinguishsolidsolitarypulmonarylesion