Cargando…

Reproducibility and Repeatability of CBCT-Derived Radiomics Features

PURPOSE: This study was conducted in order to determine the reproducibility and repeatability of cone-beam computed tomography (CBCT) radiomics features. METHODS: The first-, second-, and fifth-day CBCT images from 10 head and neck (H&N) cancer patients and 10 pelvic cancer patients were retrosp...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Hao, Zhou, Yongkang, Wang, Xiao, Zhang, Yin, Ma, Chi, Liu, Bo, Kong, Qing, Yue, Ning, Xu, Zhiyong, Nie, Ke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8637922/
https://www.ncbi.nlm.nih.gov/pubmed/34869015
http://dx.doi.org/10.3389/fonc.2021.773512
_version_ 1784608846586576896
author Wang, Hao
Zhou, Yongkang
Wang, Xiao
Zhang, Yin
Ma, Chi
Liu, Bo
Kong, Qing
Yue, Ning
Xu, Zhiyong
Nie, Ke
author_facet Wang, Hao
Zhou, Yongkang
Wang, Xiao
Zhang, Yin
Ma, Chi
Liu, Bo
Kong, Qing
Yue, Ning
Xu, Zhiyong
Nie, Ke
author_sort Wang, Hao
collection PubMed
description PURPOSE: This study was conducted in order to determine the reproducibility and repeatability of cone-beam computed tomography (CBCT) radiomics features. METHODS: The first-, second-, and fifth-day CBCT images from 10 head and neck (H&N) cancer patients and 10 pelvic cancer patients were retrospectively collected for this study. Eighteen common radiomics features were extracted from the longitudinal CBCT images using two radiomics packages. The reproducibility of CBCT-derived radiomics features was assessed using the first-day image as input and compared across the two software packages. The site-specific intraclass correlation coefficient (ICC) was used to quantitatively assess the agreement between packages. The repeatability of CBCT-based radiomics features was evaluated by comparing the following days of CBCT to the first-day image and quantified using site-specific concordance correlation coefficient (CCC). Furthermore, the correlation with volume for all the features was assessed with linear regression and R (2) as correlation parameters. RESULTS: The first-order histogram-based features such as skewness and entropy showed good agreement computed in either software package (ICCs ≥ 0.80), while the kurtosis measurements were consistent in H&N patients between the two software tools but not in pelvic cases. The ICCs for GLCM-based features showed good agreement (ICCs ≥ 0.80) between packages in both H&N and pelvic groups except for the GLCM-correction. The GLRLM-based texture features were overall less consistent as calculated by the two different software packages compared with the GLCM-based features. The CCC values of all first-order and second-order GLCM features (except GLCM-energy) were all above 0.80 from the 2-day part test–retest set, while the CCC values all dropped below the cutoff after 5-day treatment scans. All first-order histogram-based and GLCM-texture-based features were not highly correlated with volume, while two GLRLM features, in both H&N and pelvic cohorts, showed R (2) ≥0.8, meaning a high correlation with volume. CONCLUSION: The reproducibility and repeatability of CBCT-based radiomics features were assessed and compared for the first time on both H&N and pelvic sites. There were overlaps of stable features in both disease sites, yet the overall stability of radiomics features may be disease-/protocol-specific and a function of time between scans.
format Online
Article
Text
id pubmed-8637922
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-86379222021-12-03 Reproducibility and Repeatability of CBCT-Derived Radiomics Features Wang, Hao Zhou, Yongkang Wang, Xiao Zhang, Yin Ma, Chi Liu, Bo Kong, Qing Yue, Ning Xu, Zhiyong Nie, Ke Front Oncol Oncology PURPOSE: This study was conducted in order to determine the reproducibility and repeatability of cone-beam computed tomography (CBCT) radiomics features. METHODS: The first-, second-, and fifth-day CBCT images from 10 head and neck (H&N) cancer patients and 10 pelvic cancer patients were retrospectively collected for this study. Eighteen common radiomics features were extracted from the longitudinal CBCT images using two radiomics packages. The reproducibility of CBCT-derived radiomics features was assessed using the first-day image as input and compared across the two software packages. The site-specific intraclass correlation coefficient (ICC) was used to quantitatively assess the agreement between packages. The repeatability of CBCT-based radiomics features was evaluated by comparing the following days of CBCT to the first-day image and quantified using site-specific concordance correlation coefficient (CCC). Furthermore, the correlation with volume for all the features was assessed with linear regression and R (2) as correlation parameters. RESULTS: The first-order histogram-based features such as skewness and entropy showed good agreement computed in either software package (ICCs ≥ 0.80), while the kurtosis measurements were consistent in H&N patients between the two software tools but not in pelvic cases. The ICCs for GLCM-based features showed good agreement (ICCs ≥ 0.80) between packages in both H&N and pelvic groups except for the GLCM-correction. The GLRLM-based texture features were overall less consistent as calculated by the two different software packages compared with the GLCM-based features. The CCC values of all first-order and second-order GLCM features (except GLCM-energy) were all above 0.80 from the 2-day part test–retest set, while the CCC values all dropped below the cutoff after 5-day treatment scans. All first-order histogram-based and GLCM-texture-based features were not highly correlated with volume, while two GLRLM features, in both H&N and pelvic cohorts, showed R (2) ≥0.8, meaning a high correlation with volume. CONCLUSION: The reproducibility and repeatability of CBCT-based radiomics features were assessed and compared for the first time on both H&N and pelvic sites. There were overlaps of stable features in both disease sites, yet the overall stability of radiomics features may be disease-/protocol-specific and a function of time between scans. Frontiers Media S.A. 2021-11-17 /pmc/articles/PMC8637922/ /pubmed/34869015 http://dx.doi.org/10.3389/fonc.2021.773512 Text en Copyright © 2021 Wang, Zhou, Wang, Zhang, Ma, Liu, Kong, Yue, Xu and Nie https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Wang, Hao
Zhou, Yongkang
Wang, Xiao
Zhang, Yin
Ma, Chi
Liu, Bo
Kong, Qing
Yue, Ning
Xu, Zhiyong
Nie, Ke
Reproducibility and Repeatability of CBCT-Derived Radiomics Features
title Reproducibility and Repeatability of CBCT-Derived Radiomics Features
title_full Reproducibility and Repeatability of CBCT-Derived Radiomics Features
title_fullStr Reproducibility and Repeatability of CBCT-Derived Radiomics Features
title_full_unstemmed Reproducibility and Repeatability of CBCT-Derived Radiomics Features
title_short Reproducibility and Repeatability of CBCT-Derived Radiomics Features
title_sort reproducibility and repeatability of cbct-derived radiomics features
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8637922/
https://www.ncbi.nlm.nih.gov/pubmed/34869015
http://dx.doi.org/10.3389/fonc.2021.773512
work_keys_str_mv AT wanghao reproducibilityandrepeatabilityofcbctderivedradiomicsfeatures
AT zhouyongkang reproducibilityandrepeatabilityofcbctderivedradiomicsfeatures
AT wangxiao reproducibilityandrepeatabilityofcbctderivedradiomicsfeatures
AT zhangyin reproducibilityandrepeatabilityofcbctderivedradiomicsfeatures
AT machi reproducibilityandrepeatabilityofcbctderivedradiomicsfeatures
AT liubo reproducibilityandrepeatabilityofcbctderivedradiomicsfeatures
AT kongqing reproducibilityandrepeatabilityofcbctderivedradiomicsfeatures
AT yuening reproducibilityandrepeatabilityofcbctderivedradiomicsfeatures
AT xuzhiyong reproducibilityandrepeatabilityofcbctderivedradiomicsfeatures
AT nieke reproducibilityandrepeatabilityofcbctderivedradiomicsfeatures