A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy
BACKGROUND: To compare the perioperative and short-term efficacy and cost of the da Vinci Xi and da Vinci Si surgical systems for radical prostatectomy. METHODS: We retrospectively analyzed the clinical data of 175 patients with prostate cancer who underwent radical prostatectomy with the da Vinci S...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8638093/ https://www.ncbi.nlm.nih.gov/pubmed/34847882 http://dx.doi.org/10.1186/s12893-021-01406-w |
_version_ | 1784608882890375168 |
---|---|
author | Lei, Kun-Yang Xie, Wen-Jie Fu, Sheng-Qiang Ma, Ming Sun, Ting |
author_facet | Lei, Kun-Yang Xie, Wen-Jie Fu, Sheng-Qiang Ma, Ming Sun, Ting |
author_sort | Lei, Kun-Yang |
collection | PubMed |
description | BACKGROUND: To compare the perioperative and short-term efficacy and cost of the da Vinci Xi and da Vinci Si surgical systems for radical prostatectomy. METHODS: We retrospectively analyzed the clinical data of 175 patients with prostate cancer who underwent radical prostatectomy with the da Vinci Si or Xi surgical systems in our hospital from June 2019 to June 2020. Of the 175 patients, 82 underwent robot-assisted laparoscopic radical prostatectomy with the da Vinci Xi surgery system, and 93 patients underwent robot-assisted laparoscopic radical prostatectomy with the da Vinci Si surgical system. The perioperative outcomes, short-term efficacy and costs were compared between the two groups. RESULTS: The anesthesia time, operation time, docking time, indwelling catheter time and postoperative bed rest time in the Xi group were shorter than those in the Si group (respectively, 268.8 min vs. 219.3 min, P = 0.001; 228.2 min vs. 259.6 min, P < 0.001; 7.4 min vs. 12.7 min, P < 0.001; 8.6 d vs. 9.7 d, P = 0.036; 2.2 d vs. 2.6 d, P = 0.002). However, the total cost of hospitalization and the cost of intraoperative consumables in the Xi group were higher than those in the Si group (84,740.7 vs. 76,739.1 ¥, P = 0.003; 13,199.4 vs. 10,823.0 ¥, P = 0.019). CONCLUSIONS: Although the cost of robot-assisted radical prostatectomy is higher, compared with the Si system, the Xi system has better perioperative outcomes and can provide similar short-term efficacy and oncology outcomes. |
format | Online Article Text |
id | pubmed-8638093 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-86380932021-12-02 A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy Lei, Kun-Yang Xie, Wen-Jie Fu, Sheng-Qiang Ma, Ming Sun, Ting BMC Surg Research BACKGROUND: To compare the perioperative and short-term efficacy and cost of the da Vinci Xi and da Vinci Si surgical systems for radical prostatectomy. METHODS: We retrospectively analyzed the clinical data of 175 patients with prostate cancer who underwent radical prostatectomy with the da Vinci Si or Xi surgical systems in our hospital from June 2019 to June 2020. Of the 175 patients, 82 underwent robot-assisted laparoscopic radical prostatectomy with the da Vinci Xi surgery system, and 93 patients underwent robot-assisted laparoscopic radical prostatectomy with the da Vinci Si surgical system. The perioperative outcomes, short-term efficacy and costs were compared between the two groups. RESULTS: The anesthesia time, operation time, docking time, indwelling catheter time and postoperative bed rest time in the Xi group were shorter than those in the Si group (respectively, 268.8 min vs. 219.3 min, P = 0.001; 228.2 min vs. 259.6 min, P < 0.001; 7.4 min vs. 12.7 min, P < 0.001; 8.6 d vs. 9.7 d, P = 0.036; 2.2 d vs. 2.6 d, P = 0.002). However, the total cost of hospitalization and the cost of intraoperative consumables in the Xi group were higher than those in the Si group (84,740.7 vs. 76,739.1 ¥, P = 0.003; 13,199.4 vs. 10,823.0 ¥, P = 0.019). CONCLUSIONS: Although the cost of robot-assisted radical prostatectomy is higher, compared with the Si system, the Xi system has better perioperative outcomes and can provide similar short-term efficacy and oncology outcomes. BioMed Central 2021-11-30 /pmc/articles/PMC8638093/ /pubmed/34847882 http://dx.doi.org/10.1186/s12893-021-01406-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Lei, Kun-Yang Xie, Wen-Jie Fu, Sheng-Qiang Ma, Ming Sun, Ting A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy |
title | A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy |
title_full | A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy |
title_fullStr | A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy |
title_full_unstemmed | A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy |
title_short | A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy |
title_sort | comparison of the da vinci xi vs. da vinci si surgical systems for radical prostatectomy |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8638093/ https://www.ncbi.nlm.nih.gov/pubmed/34847882 http://dx.doi.org/10.1186/s12893-021-01406-w |
work_keys_str_mv | AT leikunyang acomparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy AT xiewenjie acomparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy AT fushengqiang acomparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy AT maming acomparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy AT sunting acomparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy AT leikunyang comparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy AT xiewenjie comparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy AT fushengqiang comparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy AT maming comparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy AT sunting comparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy |