A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy

BACKGROUND: To compare the perioperative and short-term efficacy and cost of the da Vinci Xi and da Vinci Si surgical systems for radical prostatectomy. METHODS: We retrospectively analyzed the clinical data of 175 patients with prostate cancer who underwent radical prostatectomy with the da Vinci S...

Descripción completa

Detalles Bibliográficos
Autores principales: Lei, Kun-Yang, Xie, Wen-Jie, Fu, Sheng-Qiang, Ma, Ming, Sun, Ting
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8638093/
https://www.ncbi.nlm.nih.gov/pubmed/34847882
http://dx.doi.org/10.1186/s12893-021-01406-w
_version_ 1784608882890375168
author Lei, Kun-Yang
Xie, Wen-Jie
Fu, Sheng-Qiang
Ma, Ming
Sun, Ting
author_facet Lei, Kun-Yang
Xie, Wen-Jie
Fu, Sheng-Qiang
Ma, Ming
Sun, Ting
author_sort Lei, Kun-Yang
collection PubMed
description BACKGROUND: To compare the perioperative and short-term efficacy and cost of the da Vinci Xi and da Vinci Si surgical systems for radical prostatectomy. METHODS: We retrospectively analyzed the clinical data of 175 patients with prostate cancer who underwent radical prostatectomy with the da Vinci Si or Xi surgical systems in our hospital from June 2019 to June 2020. Of the 175 patients, 82 underwent robot-assisted laparoscopic radical prostatectomy with the da Vinci Xi surgery system, and 93 patients underwent robot-assisted laparoscopic radical prostatectomy with the da Vinci Si surgical system. The perioperative outcomes, short-term efficacy and costs were compared between the two groups. RESULTS: The anesthesia time, operation time, docking time, indwelling catheter time and postoperative bed rest time in the Xi group were shorter than those in the Si group (respectively, 268.8 min vs. 219.3 min, P = 0.001; 228.2 min vs. 259.6 min, P < 0.001; 7.4 min vs. 12.7 min, P < 0.001; 8.6 d vs. 9.7 d, P = 0.036; 2.2 d vs. 2.6 d, P = 0.002). However, the total cost of hospitalization and the cost of intraoperative consumables in the Xi group were higher than those in the Si group (84,740.7 vs. 76,739.1 ¥, P = 0.003; 13,199.4 vs. 10,823.0 ¥, P = 0.019). CONCLUSIONS: Although the cost of robot-assisted radical prostatectomy is higher, compared with the Si system, the Xi system has better perioperative outcomes and can provide similar short-term efficacy and oncology outcomes.
format Online
Article
Text
id pubmed-8638093
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-86380932021-12-02 A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy Lei, Kun-Yang Xie, Wen-Jie Fu, Sheng-Qiang Ma, Ming Sun, Ting BMC Surg Research BACKGROUND: To compare the perioperative and short-term efficacy and cost of the da Vinci Xi and da Vinci Si surgical systems for radical prostatectomy. METHODS: We retrospectively analyzed the clinical data of 175 patients with prostate cancer who underwent radical prostatectomy with the da Vinci Si or Xi surgical systems in our hospital from June 2019 to June 2020. Of the 175 patients, 82 underwent robot-assisted laparoscopic radical prostatectomy with the da Vinci Xi surgery system, and 93 patients underwent robot-assisted laparoscopic radical prostatectomy with the da Vinci Si surgical system. The perioperative outcomes, short-term efficacy and costs were compared between the two groups. RESULTS: The anesthesia time, operation time, docking time, indwelling catheter time and postoperative bed rest time in the Xi group were shorter than those in the Si group (respectively, 268.8 min vs. 219.3 min, P = 0.001; 228.2 min vs. 259.6 min, P < 0.001; 7.4 min vs. 12.7 min, P < 0.001; 8.6 d vs. 9.7 d, P = 0.036; 2.2 d vs. 2.6 d, P = 0.002). However, the total cost of hospitalization and the cost of intraoperative consumables in the Xi group were higher than those in the Si group (84,740.7 vs. 76,739.1 ¥, P = 0.003; 13,199.4 vs. 10,823.0 ¥, P = 0.019). CONCLUSIONS: Although the cost of robot-assisted radical prostatectomy is higher, compared with the Si system, the Xi system has better perioperative outcomes and can provide similar short-term efficacy and oncology outcomes. BioMed Central 2021-11-30 /pmc/articles/PMC8638093/ /pubmed/34847882 http://dx.doi.org/10.1186/s12893-021-01406-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Lei, Kun-Yang
Xie, Wen-Jie
Fu, Sheng-Qiang
Ma, Ming
Sun, Ting
A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy
title A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy
title_full A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy
title_fullStr A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy
title_full_unstemmed A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy
title_short A comparison of the da Vinci Xi vs. da Vinci Si surgical systems for radical prostatectomy
title_sort comparison of the da vinci xi vs. da vinci si surgical systems for radical prostatectomy
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8638093/
https://www.ncbi.nlm.nih.gov/pubmed/34847882
http://dx.doi.org/10.1186/s12893-021-01406-w
work_keys_str_mv AT leikunyang acomparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy
AT xiewenjie acomparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy
AT fushengqiang acomparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy
AT maming acomparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy
AT sunting acomparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy
AT leikunyang comparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy
AT xiewenjie comparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy
AT fushengqiang comparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy
AT maming comparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy
AT sunting comparisonofthedavincixivsdavincisisurgicalsystemsforradicalprostatectomy