Cargando…
Reduction of metal artifacts from knee tumor prostheses on CT images: value of the single energy metal artifact reduction (SEMAR) algorithm
BACKGROUND: To evaluate the effect of the single energy metal artifact reduction (SEMAR) algorithm with a multidetector CT (MDCT) for knee tumor prostheses. METHODS: First, a phantom of knee tumor prosthesis underwent a MDCT scan. The raw data was reconstructed by iterative reconstruction (IR) alone...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8638139/ https://www.ncbi.nlm.nih.gov/pubmed/34856926 http://dx.doi.org/10.1186/s12885-021-09029-3 |
_version_ | 1784608891331411968 |
---|---|
author | Zhang, Fang-ling Li, Ruo-cheng Zhang, Xiao-ling Zhang, Zhao-hui Ma, Ling Ding, Lei |
author_facet | Zhang, Fang-ling Li, Ruo-cheng Zhang, Xiao-ling Zhang, Zhao-hui Ma, Ling Ding, Lei |
author_sort | Zhang, Fang-ling |
collection | PubMed |
description | BACKGROUND: To evaluate the effect of the single energy metal artifact reduction (SEMAR) algorithm with a multidetector CT (MDCT) for knee tumor prostheses. METHODS: First, a phantom of knee tumor prosthesis underwent a MDCT scan. The raw data was reconstructed by iterative reconstruction (IR) alone and IR plus SEMAR. The mean value of the CT number and the image noise were measured around the prosthesis at the stem level and articular level. Second, 95 consecutive patients with knee tumor prostheses underwent MDCT scans. The raw data were also reconstructed by the two methods. Periprosthetic structures were selected at the similar two levels. Four radiologists visually graded the image quality on a scale from 0 to 5. Additionally, the readers also assessed the presence of prosthetic complication and tumor recurrence on a same scale. RESULTS: In the phantom, when the SEMAR was used, the CT numbers were closer to normal value and the noise of images using soft and sharper kernel were respectively reduced by up to 77.1% and 43.4% at the stem level, and by up to 82.2% and 64.5% at the articular level. The subjective scores increased 1 ~ 3 points and 1 ~ 4 points at the two levels, respectively. Prosthetic complications and tumor recurrence were diagnosed in 66 patients. And the SEMAR increased the diagnostic confidence of prosthetic complications and tumor recurrence (4 ~ 5 vs. 1 ~ 1.5). CONCLUSIONS: The SEMAR algorithm can significantly reduce the metal artifacts and increase diagnostic confidence of prosthetic complications and tumor recurrence in patients with knee tumor prostheses. |
format | Online Article Text |
id | pubmed-8638139 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-86381392021-12-02 Reduction of metal artifacts from knee tumor prostheses on CT images: value of the single energy metal artifact reduction (SEMAR) algorithm Zhang, Fang-ling Li, Ruo-cheng Zhang, Xiao-ling Zhang, Zhao-hui Ma, Ling Ding, Lei BMC Cancer Research BACKGROUND: To evaluate the effect of the single energy metal artifact reduction (SEMAR) algorithm with a multidetector CT (MDCT) for knee tumor prostheses. METHODS: First, a phantom of knee tumor prosthesis underwent a MDCT scan. The raw data was reconstructed by iterative reconstruction (IR) alone and IR plus SEMAR. The mean value of the CT number and the image noise were measured around the prosthesis at the stem level and articular level. Second, 95 consecutive patients with knee tumor prostheses underwent MDCT scans. The raw data were also reconstructed by the two methods. Periprosthetic structures were selected at the similar two levels. Four radiologists visually graded the image quality on a scale from 0 to 5. Additionally, the readers also assessed the presence of prosthetic complication and tumor recurrence on a same scale. RESULTS: In the phantom, when the SEMAR was used, the CT numbers were closer to normal value and the noise of images using soft and sharper kernel were respectively reduced by up to 77.1% and 43.4% at the stem level, and by up to 82.2% and 64.5% at the articular level. The subjective scores increased 1 ~ 3 points and 1 ~ 4 points at the two levels, respectively. Prosthetic complications and tumor recurrence were diagnosed in 66 patients. And the SEMAR increased the diagnostic confidence of prosthetic complications and tumor recurrence (4 ~ 5 vs. 1 ~ 1.5). CONCLUSIONS: The SEMAR algorithm can significantly reduce the metal artifacts and increase diagnostic confidence of prosthetic complications and tumor recurrence in patients with knee tumor prostheses. BioMed Central 2021-12-02 /pmc/articles/PMC8638139/ /pubmed/34856926 http://dx.doi.org/10.1186/s12885-021-09029-3 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Zhang, Fang-ling Li, Ruo-cheng Zhang, Xiao-ling Zhang, Zhao-hui Ma, Ling Ding, Lei Reduction of metal artifacts from knee tumor prostheses on CT images: value of the single energy metal artifact reduction (SEMAR) algorithm |
title | Reduction of metal artifacts from knee tumor prostheses on CT images: value of the single energy metal artifact reduction (SEMAR) algorithm |
title_full | Reduction of metal artifacts from knee tumor prostheses on CT images: value of the single energy metal artifact reduction (SEMAR) algorithm |
title_fullStr | Reduction of metal artifacts from knee tumor prostheses on CT images: value of the single energy metal artifact reduction (SEMAR) algorithm |
title_full_unstemmed | Reduction of metal artifacts from knee tumor prostheses on CT images: value of the single energy metal artifact reduction (SEMAR) algorithm |
title_short | Reduction of metal artifacts from knee tumor prostheses on CT images: value of the single energy metal artifact reduction (SEMAR) algorithm |
title_sort | reduction of metal artifacts from knee tumor prostheses on ct images: value of the single energy metal artifact reduction (semar) algorithm |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8638139/ https://www.ncbi.nlm.nih.gov/pubmed/34856926 http://dx.doi.org/10.1186/s12885-021-09029-3 |
work_keys_str_mv | AT zhangfangling reductionofmetalartifactsfromkneetumorprosthesesonctimagesvalueofthesingleenergymetalartifactreductionsemaralgorithm AT liruocheng reductionofmetalartifactsfromkneetumorprosthesesonctimagesvalueofthesingleenergymetalartifactreductionsemaralgorithm AT zhangxiaoling reductionofmetalartifactsfromkneetumorprosthesesonctimagesvalueofthesingleenergymetalartifactreductionsemaralgorithm AT zhangzhaohui reductionofmetalartifactsfromkneetumorprosthesesonctimagesvalueofthesingleenergymetalartifactreductionsemaralgorithm AT maling reductionofmetalartifactsfromkneetumorprosthesesonctimagesvalueofthesingleenergymetalartifactreductionsemaralgorithm AT dinglei reductionofmetalartifactsfromkneetumorprosthesesonctimagesvalueofthesingleenergymetalartifactreductionsemaralgorithm |