Cargando…
Joint reconstruction framework of compressed sensing and nonlinear parallel imaging for dynamic cardiac magnetic resonance imaging
Compressed Sensing (CS) and parallel imaging are two promising techniques that accelerate the MRI acquisition process. Combining these two techniques is of great interest due to the complementary information used in each. In this study, we proposed a novel reconstruction framework that effectively c...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8638482/ https://www.ncbi.nlm.nih.gov/pubmed/34852771 http://dx.doi.org/10.1186/s12880-021-00685-2 |
_version_ | 1784608955204370432 |
---|---|
author | Hu, Zhanqi Zhao, Cailei Zhao, Xia Kong, Lingyu Yang, Jun Wang, Xiaoyan Liao, Jianxiang Zhou, Yihang |
author_facet | Hu, Zhanqi Zhao, Cailei Zhao, Xia Kong, Lingyu Yang, Jun Wang, Xiaoyan Liao, Jianxiang Zhou, Yihang |
author_sort | Hu, Zhanqi |
collection | PubMed |
description | Compressed Sensing (CS) and parallel imaging are two promising techniques that accelerate the MRI acquisition process. Combining these two techniques is of great interest due to the complementary information used in each. In this study, we proposed a novel reconstruction framework that effectively combined compressed sensing and nonlinear parallel imaging technique for dynamic cardiac imaging. Specifically, the proposed method decouples the reconstruction process into two sequential steps: In the first step, a series of aliased dynamic images were reconstructed from the highly undersampled k-space data using compressed sensing; In the second step, nonlinear parallel imaging technique, i.e. nonlinear GRAPPA, was utilized to reconstruct the original dynamic images from the reconstructed k-space data obtained from the first step. In addition, we also proposed a tailored k-space down-sampling scheme that satisfies both the incoherent undersampling requirement for CS and the structured undersampling requirement for nonlinear parallel imaging. The proposed method was validated using four in vivo experiments of dynamic cardiac cine MRI with retrospective undersampling. Experimental results showed that the proposed method is superior at reducing aliasing artifacts and preserving the spatial details and temporal variations, compared with the competing k-t FOCUSS and k-t FOCUSS with sensitivity encoding methods, with the same numbers of measurements. |
format | Online Article Text |
id | pubmed-8638482 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-86384822021-12-03 Joint reconstruction framework of compressed sensing and nonlinear parallel imaging for dynamic cardiac magnetic resonance imaging Hu, Zhanqi Zhao, Cailei Zhao, Xia Kong, Lingyu Yang, Jun Wang, Xiaoyan Liao, Jianxiang Zhou, Yihang BMC Med Imaging Research Compressed Sensing (CS) and parallel imaging are two promising techniques that accelerate the MRI acquisition process. Combining these two techniques is of great interest due to the complementary information used in each. In this study, we proposed a novel reconstruction framework that effectively combined compressed sensing and nonlinear parallel imaging technique for dynamic cardiac imaging. Specifically, the proposed method decouples the reconstruction process into two sequential steps: In the first step, a series of aliased dynamic images were reconstructed from the highly undersampled k-space data using compressed sensing; In the second step, nonlinear parallel imaging technique, i.e. nonlinear GRAPPA, was utilized to reconstruct the original dynamic images from the reconstructed k-space data obtained from the first step. In addition, we also proposed a tailored k-space down-sampling scheme that satisfies both the incoherent undersampling requirement for CS and the structured undersampling requirement for nonlinear parallel imaging. The proposed method was validated using four in vivo experiments of dynamic cardiac cine MRI with retrospective undersampling. Experimental results showed that the proposed method is superior at reducing aliasing artifacts and preserving the spatial details and temporal variations, compared with the competing k-t FOCUSS and k-t FOCUSS with sensitivity encoding methods, with the same numbers of measurements. BioMed Central 2021-12-01 /pmc/articles/PMC8638482/ /pubmed/34852771 http://dx.doi.org/10.1186/s12880-021-00685-2 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Hu, Zhanqi Zhao, Cailei Zhao, Xia Kong, Lingyu Yang, Jun Wang, Xiaoyan Liao, Jianxiang Zhou, Yihang Joint reconstruction framework of compressed sensing and nonlinear parallel imaging for dynamic cardiac magnetic resonance imaging |
title | Joint reconstruction framework of compressed sensing and nonlinear parallel imaging for dynamic cardiac magnetic resonance imaging |
title_full | Joint reconstruction framework of compressed sensing and nonlinear parallel imaging for dynamic cardiac magnetic resonance imaging |
title_fullStr | Joint reconstruction framework of compressed sensing and nonlinear parallel imaging for dynamic cardiac magnetic resonance imaging |
title_full_unstemmed | Joint reconstruction framework of compressed sensing and nonlinear parallel imaging for dynamic cardiac magnetic resonance imaging |
title_short | Joint reconstruction framework of compressed sensing and nonlinear parallel imaging for dynamic cardiac magnetic resonance imaging |
title_sort | joint reconstruction framework of compressed sensing and nonlinear parallel imaging for dynamic cardiac magnetic resonance imaging |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8638482/ https://www.ncbi.nlm.nih.gov/pubmed/34852771 http://dx.doi.org/10.1186/s12880-021-00685-2 |
work_keys_str_mv | AT huzhanqi jointreconstructionframeworkofcompressedsensingandnonlinearparallelimagingfordynamiccardiacmagneticresonanceimaging AT zhaocailei jointreconstructionframeworkofcompressedsensingandnonlinearparallelimagingfordynamiccardiacmagneticresonanceimaging AT zhaoxia jointreconstructionframeworkofcompressedsensingandnonlinearparallelimagingfordynamiccardiacmagneticresonanceimaging AT konglingyu jointreconstructionframeworkofcompressedsensingandnonlinearparallelimagingfordynamiccardiacmagneticresonanceimaging AT yangjun jointreconstructionframeworkofcompressedsensingandnonlinearparallelimagingfordynamiccardiacmagneticresonanceimaging AT wangxiaoyan jointreconstructionframeworkofcompressedsensingandnonlinearparallelimagingfordynamiccardiacmagneticresonanceimaging AT liaojianxiang jointreconstructionframeworkofcompressedsensingandnonlinearparallelimagingfordynamiccardiacmagneticresonanceimaging AT zhouyihang jointreconstructionframeworkofcompressedsensingandnonlinearparallelimagingfordynamiccardiacmagneticresonanceimaging |