Cargando…

A multi spin echo pulse sequence with optimized excitation pulses and a 3D cone readout for hyperpolarized (13)C imaging

PURPOSE: Imaging tumor metabolism in vivo using hyperpolarized [1‐(13)C]pyruvate is a promising technique for detecting disease, monitoring disease progression, and assessing treatment response. However, the transient nature of the hyperpolarization and its depletion following excitation limits the...

Descripción completa

Detalles Bibliográficos
Autores principales: Somai, Vencel, Wright, Alan J., Fala, Maria, Hesse, Friederike, Brindle, Kevin M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8638674/
https://www.ncbi.nlm.nih.gov/pubmed/32173908
http://dx.doi.org/10.1002/mrm.28248
_version_ 1784608989352296448
author Somai, Vencel
Wright, Alan J.
Fala, Maria
Hesse, Friederike
Brindle, Kevin M.
author_facet Somai, Vencel
Wright, Alan J.
Fala, Maria
Hesse, Friederike
Brindle, Kevin M.
author_sort Somai, Vencel
collection PubMed
description PURPOSE: Imaging tumor metabolism in vivo using hyperpolarized [1‐(13)C]pyruvate is a promising technique for detecting disease, monitoring disease progression, and assessing treatment response. However, the transient nature of the hyperpolarization and its depletion following excitation limits the available time for imaging. We describe here a single‐shot multi spin echo sequence, which improves on previously reported sequences, with a shorter readout time, isotropic point spread function (PSF), and better signal‐to‐noise ratio. METHODS: The sequence uses numerically optimized spectrally selective excitation pulses set to the resonant frequencies of pyruvate and lactate and a hyperbolic secant adiabatic refocusing pulse, all applied in the absence of slice selection gradients. The excitation pulses were designed to be resistant to the effects of B(0) and B(1) field inhomogeneity. The gradient readout uses a 3D cone trajectory composed of 13 cones, all fully refocused and distributed among 7 spin echoes. The maximal gradient amplitude and slew rate were set to 4 G/cm and 20 G/cm/ms, respectively, to demonstrate the feasibility of clinical translation. RESULTS: The pulse sequence gave an isotropic PSF of 2.8 mm. The excitation profiles of the optimized pulses closely matched simulations and a 46.10 ± 0.04% gain in image SNR was observed compared to a conventional Shinnar–Le Roux excitation pulse. The sequence was demonstrated with dynamic imaging of hyperpolarized [1‐(13)C]pyruvate and [1‐(13)C]lactate in vivo. CONCLUSION: The pulse sequence was capable of dynamic imaging of hyperpolarized (13)C labeled metabolites in vivo with relatively high spatial and temporal resolution and immunity to system imperfections.
format Online
Article
Text
id pubmed-8638674
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-86386742021-12-09 A multi spin echo pulse sequence with optimized excitation pulses and a 3D cone readout for hyperpolarized (13)C imaging Somai, Vencel Wright, Alan J. Fala, Maria Hesse, Friederike Brindle, Kevin M. Magn Reson Med Full Papers—Imaging Methodology PURPOSE: Imaging tumor metabolism in vivo using hyperpolarized [1‐(13)C]pyruvate is a promising technique for detecting disease, monitoring disease progression, and assessing treatment response. However, the transient nature of the hyperpolarization and its depletion following excitation limits the available time for imaging. We describe here a single‐shot multi spin echo sequence, which improves on previously reported sequences, with a shorter readout time, isotropic point spread function (PSF), and better signal‐to‐noise ratio. METHODS: The sequence uses numerically optimized spectrally selective excitation pulses set to the resonant frequencies of pyruvate and lactate and a hyperbolic secant adiabatic refocusing pulse, all applied in the absence of slice selection gradients. The excitation pulses were designed to be resistant to the effects of B(0) and B(1) field inhomogeneity. The gradient readout uses a 3D cone trajectory composed of 13 cones, all fully refocused and distributed among 7 spin echoes. The maximal gradient amplitude and slew rate were set to 4 G/cm and 20 G/cm/ms, respectively, to demonstrate the feasibility of clinical translation. RESULTS: The pulse sequence gave an isotropic PSF of 2.8 mm. The excitation profiles of the optimized pulses closely matched simulations and a 46.10 ± 0.04% gain in image SNR was observed compared to a conventional Shinnar–Le Roux excitation pulse. The sequence was demonstrated with dynamic imaging of hyperpolarized [1‐(13)C]pyruvate and [1‐(13)C]lactate in vivo. CONCLUSION: The pulse sequence was capable of dynamic imaging of hyperpolarized (13)C labeled metabolites in vivo with relatively high spatial and temporal resolution and immunity to system imperfections. John Wiley and Sons Inc. 2020-03-15 2020-10 /pmc/articles/PMC8638674/ /pubmed/32173908 http://dx.doi.org/10.1002/mrm.28248 Text en © 2020 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Papers—Imaging Methodology
Somai, Vencel
Wright, Alan J.
Fala, Maria
Hesse, Friederike
Brindle, Kevin M.
A multi spin echo pulse sequence with optimized excitation pulses and a 3D cone readout for hyperpolarized (13)C imaging
title A multi spin echo pulse sequence with optimized excitation pulses and a 3D cone readout for hyperpolarized (13)C imaging
title_full A multi spin echo pulse sequence with optimized excitation pulses and a 3D cone readout for hyperpolarized (13)C imaging
title_fullStr A multi spin echo pulse sequence with optimized excitation pulses and a 3D cone readout for hyperpolarized (13)C imaging
title_full_unstemmed A multi spin echo pulse sequence with optimized excitation pulses and a 3D cone readout for hyperpolarized (13)C imaging
title_short A multi spin echo pulse sequence with optimized excitation pulses and a 3D cone readout for hyperpolarized (13)C imaging
title_sort multi spin echo pulse sequence with optimized excitation pulses and a 3d cone readout for hyperpolarized (13)c imaging
topic Full Papers—Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8638674/
https://www.ncbi.nlm.nih.gov/pubmed/32173908
http://dx.doi.org/10.1002/mrm.28248
work_keys_str_mv AT somaivencel amultispinechopulsesequencewithoptimizedexcitationpulsesanda3dconereadoutforhyperpolarized13cimaging
AT wrightalanj amultispinechopulsesequencewithoptimizedexcitationpulsesanda3dconereadoutforhyperpolarized13cimaging
AT falamaria amultispinechopulsesequencewithoptimizedexcitationpulsesanda3dconereadoutforhyperpolarized13cimaging
AT hessefriederike amultispinechopulsesequencewithoptimizedexcitationpulsesanda3dconereadoutforhyperpolarized13cimaging
AT brindlekevinm amultispinechopulsesequencewithoptimizedexcitationpulsesanda3dconereadoutforhyperpolarized13cimaging
AT somaivencel multispinechopulsesequencewithoptimizedexcitationpulsesanda3dconereadoutforhyperpolarized13cimaging
AT wrightalanj multispinechopulsesequencewithoptimizedexcitationpulsesanda3dconereadoutforhyperpolarized13cimaging
AT falamaria multispinechopulsesequencewithoptimizedexcitationpulsesanda3dconereadoutforhyperpolarized13cimaging
AT hessefriederike multispinechopulsesequencewithoptimizedexcitationpulsesanda3dconereadoutforhyperpolarized13cimaging
AT brindlekevinm multispinechopulsesequencewithoptimizedexcitationpulsesanda3dconereadoutforhyperpolarized13cimaging