Cargando…

Electrospun tube reduces adhesion in rabbit Achilles tendon 12 weeks post-surgery without PAR-2 overexpression

One great challenge in surgical tendon repair is the minimization of peritendinous adhesions. An electrospun tube can serve as a physical barrier around a conventionally sutured tendon. Six New Zealand White rabbits had one Achilles tendon fully transsected and sutured by a 4-strand suture. Another...

Descripción completa

Detalles Bibliográficos
Autores principales: Bürgisser, Gabriella Meier, Evrova, Olivera, Heuberger, Dorothea M., Wolint, Petra, Rieber, Julia, Miescher, Iris, Schüpbach, Reto A., Giovanoli, Pietro, Calcagni, Maurizio, Buschmann, Johanna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8639666/
https://www.ncbi.nlm.nih.gov/pubmed/34857838
http://dx.doi.org/10.1038/s41598-021-02780-4
_version_ 1784609187781672960
author Bürgisser, Gabriella Meier
Evrova, Olivera
Heuberger, Dorothea M.
Wolint, Petra
Rieber, Julia
Miescher, Iris
Schüpbach, Reto A.
Giovanoli, Pietro
Calcagni, Maurizio
Buschmann, Johanna
author_facet Bürgisser, Gabriella Meier
Evrova, Olivera
Heuberger, Dorothea M.
Wolint, Petra
Rieber, Julia
Miescher, Iris
Schüpbach, Reto A.
Giovanoli, Pietro
Calcagni, Maurizio
Buschmann, Johanna
author_sort Bürgisser, Gabriella Meier
collection PubMed
description One great challenge in surgical tendon repair is the minimization of peritendinous adhesions. An electrospun tube can serve as a physical barrier around a conventionally sutured tendon. Six New Zealand White rabbits had one Achilles tendon fully transsected and sutured by a 4-strand suture. Another six rabbits had the same treatment, but with the additional electrospun DegraPol tube set around the sutured tendon. The adhesion formation to the surrounding tissue was investigated 12 weeks post-operation. Moreover, inflammation-related protease-activated receptor-2 (PAR-2) protein expression was assessed. Finally, rabbit Achilles tenocyte cultures were exposed to platelet-derived growth factor-BB (PDGF-BB), which mimicks the tendon healing environment, where PAR-2 gene expression was assessed as well as immunofluorescent staining intensity for F-actin and α-tubulin, respectively. At 12 weeks post-operation, the partially degraded DegraPol tube exhibited significantly lower adhesion formation (− 20%). PAR-2 protein expression was similar for time points 3 and 6 weeks, but increased at 12 weeks post-operation. In vitro cell culture experiments showed a significantly higher PAR-2 gene expression on day 3 after exposure to PDGF-BB, but not on day 7. The cytoskeleton of the tenocytes changed upon PDGF-BB stimulation, with signs of reorganization, and significantly decreased F-actin intensity. An electrospun DegraPol tube significantly reduces adhesion up to twelve weeks post-operation. At this time point, the tube is partially degraded, and a slight PAR-2 increase was detected in the DP treated tendons, which might however arise from particles of degrading DegraPol that were stained dark brown. PAR-2 gene expression in rabbit tenocytes reveals sensitivity at around day 10 after injury.
format Online
Article
Text
id pubmed-8639666
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-86396662021-12-03 Electrospun tube reduces adhesion in rabbit Achilles tendon 12 weeks post-surgery without PAR-2 overexpression Bürgisser, Gabriella Meier Evrova, Olivera Heuberger, Dorothea M. Wolint, Petra Rieber, Julia Miescher, Iris Schüpbach, Reto A. Giovanoli, Pietro Calcagni, Maurizio Buschmann, Johanna Sci Rep Article One great challenge in surgical tendon repair is the minimization of peritendinous adhesions. An electrospun tube can serve as a physical barrier around a conventionally sutured tendon. Six New Zealand White rabbits had one Achilles tendon fully transsected and sutured by a 4-strand suture. Another six rabbits had the same treatment, but with the additional electrospun DegraPol tube set around the sutured tendon. The adhesion formation to the surrounding tissue was investigated 12 weeks post-operation. Moreover, inflammation-related protease-activated receptor-2 (PAR-2) protein expression was assessed. Finally, rabbit Achilles tenocyte cultures were exposed to platelet-derived growth factor-BB (PDGF-BB), which mimicks the tendon healing environment, where PAR-2 gene expression was assessed as well as immunofluorescent staining intensity for F-actin and α-tubulin, respectively. At 12 weeks post-operation, the partially degraded DegraPol tube exhibited significantly lower adhesion formation (− 20%). PAR-2 protein expression was similar for time points 3 and 6 weeks, but increased at 12 weeks post-operation. In vitro cell culture experiments showed a significantly higher PAR-2 gene expression on day 3 after exposure to PDGF-BB, but not on day 7. The cytoskeleton of the tenocytes changed upon PDGF-BB stimulation, with signs of reorganization, and significantly decreased F-actin intensity. An electrospun DegraPol tube significantly reduces adhesion up to twelve weeks post-operation. At this time point, the tube is partially degraded, and a slight PAR-2 increase was detected in the DP treated tendons, which might however arise from particles of degrading DegraPol that were stained dark brown. PAR-2 gene expression in rabbit tenocytes reveals sensitivity at around day 10 after injury. Nature Publishing Group UK 2021-12-02 /pmc/articles/PMC8639666/ /pubmed/34857838 http://dx.doi.org/10.1038/s41598-021-02780-4 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Bürgisser, Gabriella Meier
Evrova, Olivera
Heuberger, Dorothea M.
Wolint, Petra
Rieber, Julia
Miescher, Iris
Schüpbach, Reto A.
Giovanoli, Pietro
Calcagni, Maurizio
Buschmann, Johanna
Electrospun tube reduces adhesion in rabbit Achilles tendon 12 weeks post-surgery without PAR-2 overexpression
title Electrospun tube reduces adhesion in rabbit Achilles tendon 12 weeks post-surgery without PAR-2 overexpression
title_full Electrospun tube reduces adhesion in rabbit Achilles tendon 12 weeks post-surgery without PAR-2 overexpression
title_fullStr Electrospun tube reduces adhesion in rabbit Achilles tendon 12 weeks post-surgery without PAR-2 overexpression
title_full_unstemmed Electrospun tube reduces adhesion in rabbit Achilles tendon 12 weeks post-surgery without PAR-2 overexpression
title_short Electrospun tube reduces adhesion in rabbit Achilles tendon 12 weeks post-surgery without PAR-2 overexpression
title_sort electrospun tube reduces adhesion in rabbit achilles tendon 12 weeks post-surgery without par-2 overexpression
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8639666/
https://www.ncbi.nlm.nih.gov/pubmed/34857838
http://dx.doi.org/10.1038/s41598-021-02780-4
work_keys_str_mv AT burgissergabriellameier electrospuntubereducesadhesioninrabbitachillestendon12weekspostsurgerywithoutpar2overexpression
AT evrovaolivera electrospuntubereducesadhesioninrabbitachillestendon12weekspostsurgerywithoutpar2overexpression
AT heubergerdorotheam electrospuntubereducesadhesioninrabbitachillestendon12weekspostsurgerywithoutpar2overexpression
AT wolintpetra electrospuntubereducesadhesioninrabbitachillestendon12weekspostsurgerywithoutpar2overexpression
AT rieberjulia electrospuntubereducesadhesioninrabbitachillestendon12weekspostsurgerywithoutpar2overexpression
AT miescheriris electrospuntubereducesadhesioninrabbitachillestendon12weekspostsurgerywithoutpar2overexpression
AT schupbachretoa electrospuntubereducesadhesioninrabbitachillestendon12weekspostsurgerywithoutpar2overexpression
AT giovanolipietro electrospuntubereducesadhesioninrabbitachillestendon12weekspostsurgerywithoutpar2overexpression
AT calcagnimaurizio electrospuntubereducesadhesioninrabbitachillestendon12weekspostsurgerywithoutpar2overexpression
AT buschmannjohanna electrospuntubereducesadhesioninrabbitachillestendon12weekspostsurgerywithoutpar2overexpression