Cargando…

EEG source imaging concordance with intracranial EEG and epileptologist review in focal epilepsy

EEG source imaging is becoming widely used for the evaluation of medically refractory focal epilepsy. The validity of EEG source imaging has been established in several studies comparing source imaging to the surgical resection cavity and subsequent seizure freedom. We present a cohort of 87 patient...

Descripción completa

Detalles Bibliográficos
Autores principales: Cox, Benjamin C, Danoun, Omar A, Lundstrom, Brian Nils, Lagerlund, Terrence D, Wong-Kisiel, Lily C, Brinkmann, Benjamin H
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8643498/
https://www.ncbi.nlm.nih.gov/pubmed/34877536
http://dx.doi.org/10.1093/braincomms/fcab278
_version_ 1784609878240657408
author Cox, Benjamin C
Danoun, Omar A
Lundstrom, Brian Nils
Lagerlund, Terrence D
Wong-Kisiel, Lily C
Brinkmann, Benjamin H
author_facet Cox, Benjamin C
Danoun, Omar A
Lundstrom, Brian Nils
Lagerlund, Terrence D
Wong-Kisiel, Lily C
Brinkmann, Benjamin H
author_sort Cox, Benjamin C
collection PubMed
description EEG source imaging is becoming widely used for the evaluation of medically refractory focal epilepsy. The validity of EEG source imaging has been established in several studies comparing source imaging to the surgical resection cavity and subsequent seizure freedom. We present a cohort of 87 patients and compare EEG source imaging of both ictal and interictal scalp EEG to the seizure onset zone on intracranial EEG. Concordance of EEG source imaging with intracranial EEG was determined on a sublobar level and was quantified by measuring the distance between the source imaging result and the centroid of the active seizure onset zone electrodes. The EEG source imaging results of a subgroup of 26 patients with high density 76-channel EEG were compared with the localization of three experienced epileptologists. Of 87 patients, 95% had at least one analysis concordant with intracranial EEG and 74% had complete concordance. There was a higher rate of complete concordance in temporal lobe epilepsy compared to extratemporal (89.3 and 62.8%, respectively, P = 0.015). Of the total 282 analyses performed on this cohort, higher concordance was also seen in temporal discharges (95%) compared to extratemporal (77%) (P = 0.0012), but no difference was seen comparing high-density EEG with standard (32-channel) EEG. Subgroup analysis of ictal waveforms showed greater concordance for ictal spiking, compared with rhythmic activity, paroxysmal fast activity, or obscured onset. Median distances from the dipole and maximum distributed source to a centroid of seizure onset zone electrodes were 30.0 and 32.5 mm, respectively, and the median distances from dipole and maximum distributed source to nearest seizure onset zone electrode were 22.8 and 21.7, respectively. There were significantly shorter distances in ictal spiking. There were shorter distances in patients with Engel Class 1 outcome from surgical resection compared to patients with worse outcomes. For the subgroup of 26 high-density EEG patients, EEG source localization had a significantly higher concordance (92% versus 65%), sensitivity (57% versus 35%) and positive predictive value (60% versus 36%) compared with epileptologist localization. Our study demonstrates good concordance between ictal and interictal source imaging and intracranial EEG. Temporal lobe discharges have higher concordance rates than extratemporal discharges. Importantly, this study shows that source imaging has greater agreement with intracranial EEG than visual review alone, supporting its role in surgical planning.
format Online
Article
Text
id pubmed-8643498
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-86434982021-12-06 EEG source imaging concordance with intracranial EEG and epileptologist review in focal epilepsy Cox, Benjamin C Danoun, Omar A Lundstrom, Brian Nils Lagerlund, Terrence D Wong-Kisiel, Lily C Brinkmann, Benjamin H Brain Commun Original Article EEG source imaging is becoming widely used for the evaluation of medically refractory focal epilepsy. The validity of EEG source imaging has been established in several studies comparing source imaging to the surgical resection cavity and subsequent seizure freedom. We present a cohort of 87 patients and compare EEG source imaging of both ictal and interictal scalp EEG to the seizure onset zone on intracranial EEG. Concordance of EEG source imaging with intracranial EEG was determined on a sublobar level and was quantified by measuring the distance between the source imaging result and the centroid of the active seizure onset zone electrodes. The EEG source imaging results of a subgroup of 26 patients with high density 76-channel EEG were compared with the localization of three experienced epileptologists. Of 87 patients, 95% had at least one analysis concordant with intracranial EEG and 74% had complete concordance. There was a higher rate of complete concordance in temporal lobe epilepsy compared to extratemporal (89.3 and 62.8%, respectively, P = 0.015). Of the total 282 analyses performed on this cohort, higher concordance was also seen in temporal discharges (95%) compared to extratemporal (77%) (P = 0.0012), but no difference was seen comparing high-density EEG with standard (32-channel) EEG. Subgroup analysis of ictal waveforms showed greater concordance for ictal spiking, compared with rhythmic activity, paroxysmal fast activity, or obscured onset. Median distances from the dipole and maximum distributed source to a centroid of seizure onset zone electrodes were 30.0 and 32.5 mm, respectively, and the median distances from dipole and maximum distributed source to nearest seizure onset zone electrode were 22.8 and 21.7, respectively. There were significantly shorter distances in ictal spiking. There were shorter distances in patients with Engel Class 1 outcome from surgical resection compared to patients with worse outcomes. For the subgroup of 26 high-density EEG patients, EEG source localization had a significantly higher concordance (92% versus 65%), sensitivity (57% versus 35%) and positive predictive value (60% versus 36%) compared with epileptologist localization. Our study demonstrates good concordance between ictal and interictal source imaging and intracranial EEG. Temporal lobe discharges have higher concordance rates than extratemporal discharges. Importantly, this study shows that source imaging has greater agreement with intracranial EEG than visual review alone, supporting its role in surgical planning. Oxford University Press 2021-11-19 /pmc/articles/PMC8643498/ /pubmed/34877536 http://dx.doi.org/10.1093/braincomms/fcab278 Text en © The Author(s) (2021). Published by Oxford University Press on behalf of the Guarantors of Brain. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Cox, Benjamin C
Danoun, Omar A
Lundstrom, Brian Nils
Lagerlund, Terrence D
Wong-Kisiel, Lily C
Brinkmann, Benjamin H
EEG source imaging concordance with intracranial EEG and epileptologist review in focal epilepsy
title EEG source imaging concordance with intracranial EEG and epileptologist review in focal epilepsy
title_full EEG source imaging concordance with intracranial EEG and epileptologist review in focal epilepsy
title_fullStr EEG source imaging concordance with intracranial EEG and epileptologist review in focal epilepsy
title_full_unstemmed EEG source imaging concordance with intracranial EEG and epileptologist review in focal epilepsy
title_short EEG source imaging concordance with intracranial EEG and epileptologist review in focal epilepsy
title_sort eeg source imaging concordance with intracranial eeg and epileptologist review in focal epilepsy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8643498/
https://www.ncbi.nlm.nih.gov/pubmed/34877536
http://dx.doi.org/10.1093/braincomms/fcab278
work_keys_str_mv AT coxbenjaminc eegsourceimagingconcordancewithintracranialeegandepileptologistreviewinfocalepilepsy
AT danounomara eegsourceimagingconcordancewithintracranialeegandepileptologistreviewinfocalepilepsy
AT lundstrombriannils eegsourceimagingconcordancewithintracranialeegandepileptologistreviewinfocalepilepsy
AT lagerlundterrenced eegsourceimagingconcordancewithintracranialeegandepileptologistreviewinfocalepilepsy
AT wongkisiellilyc eegsourceimagingconcordancewithintracranialeegandepileptologistreviewinfocalepilepsy
AT brinkmannbenjaminh eegsourceimagingconcordancewithintracranialeegandepileptologistreviewinfocalepilepsy