Cargando…

773. Hypochlorous Acid Generating Electrochemical Catheter Prototype for Prevention of Intraluminal Infections

BACKGROUND: Central-line associated bloodstream infection (CLABSI) contributes to mortality and cost. While aseptic dressings and antibiotic-impregnated catheters can prevent extraluminal infections, intraluminal infections remain a source of CLABSIs with limited prevention options. METHODS: In this...

Descripción completa

Detalles Bibliográficos
Autores principales: Flurin, Laure, Cano Cevallos, Edison J, Mohamed, Abdelrhman, Greenwood-Quaintance, Kerryl, Raval, Yash, Beyenal, Haluk, Patel, Robin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8644058/
http://dx.doi.org/10.1093/ofid/ofab466.970
Descripción
Sumario:BACKGROUND: Central-line associated bloodstream infection (CLABSI) contributes to mortality and cost. While aseptic dressings and antibiotic-impregnated catheters can prevent extraluminal infections, intraluminal infections remain a source of CLABSIs with limited prevention options. METHODS: In this proof-of-concept study, an electrochemical intravascular catheter (e-catheter) prototype capable of electrochemically generating hypochlorous acid intraluminally on the surface of platinum electrodes polarized at a constant potential of 1.5 VAg/AgCl was developed. After 24h of pre-polarization at 1.5 VAg/AgCl, their activity was tested by inoculating four clinical isolates derived from catheter-related infections, Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecium and Escherichia coli. Figure 1. In vitro catheter and e-catheter models. [Image: see text] RESULTS: E-catheters generated a mean HOCl concentration of 15.86±4.03 μM and had a mean pH of 6.14±0.79. e-catheters prevented infections with all four species, with an average reduction of 8.41±0.61 log10 CFU/mL at 48h compared to controls. Figure 3. Measurement of pH and HOCl at 48 hours in polarized e-catheters. [Image: see text] Each dot represents a replicate; bars represent means. Figure 4. Prevention of infection after 48 hours of polarization (24 hours of infections) using e-catheters (polarized and non-polarized) compared to blank catheters. [Image: see text] * indicates statistically significant reduction of cell counts in polarized e-catheter compared to blank catheter (p <0.05). CONCLUSION: Polarized e-catheters which generate low amounts of HOCl continuously should be further developed to prevent intraluminal infection. DISCLOSURES: Haluk Beyenal, Ph.D, patent (Other Financial or Material Support, HB holds a patent: Beyenal H CD, Fransson BA, Sultana ST. . 2018. Electrochemical reduction or prevention of infections. U.S. patent 20180207301A1, international patent WO/2017/011635.) Robin Patel, MD, 1928 Diagnostics (Consultant)BioFire Diagnostics (Grant/Research Support)ContraFect Corporation (Grant/Research Support)Curetis (Consultant)Hylomorph AG (Grant/Research Support)IDSA (Other Financial or Material Support, Editor's Stipend)Infectious Diseases Board Review Course (Other Financial or Material Support, Honoraria)Mammoth Biosciences (Consultant)NBME (Other Financial or Material Support, Honoraria)Netflix (Consultant)Next Gen Diagnostics (Consultant)PathoQuest (Consultant)PhAST (Consultant)Qvella (Consultant)Samsung (Other Financial or Material Support, Patent Royalties)Selux Diagnostics (Consultant)Shionogi & Co., Ltd. (Grant/Research Support)Specific Technologies (Consultant)TenNor Therapeutics Limited (Grant/Research Support)Torus Biosystems (Consultant)Up-to-Date (Other Financial or Material Support, Honoraria) Robin Patel, MD, BioFire (Individual(s) Involved: Self): Grant/Research Support; Contrafect (Individual(s) Involved: Self): Grant/Research Support; IDSA (Individual(s) Involved: Self): Editor's stipend; NBME, Up-to-Date and the Infectious Diseases Board Review Course (Individual(s) Involved: Self): Honoraria; Netflix (Individual(s) Involved: Self): Consultant; TenNor Therapeutics Limited (Individual(s) Involved: Self): Grant/Research Support; to Curetis, Specific Technologies, Next Gen Diagnostics, PathoQuest, Selux Diagnostics, 1928 Diagnostics, PhAST, Torus Biosystems, Mammoth Biosciences and Qvella (Individual(s) Involved: Self): Consultant