Cargando…
The use of imageless navigation to quantify cutting error in total knee arthroplasty
PURPOSE: Navigated total knee arthroplasty (TKA) improves implant alignment by providing feedback on resection parameters based on femoral and tibial cutting guide positions. However, saw blade thickness, deflection, and cutting guide motion may lead to final bone cuts differing from planned resecti...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8645113/ https://www.ncbi.nlm.nih.gov/pubmed/34863317 http://dx.doi.org/10.1186/s43019-021-00125-z |
_version_ | 1784610241882619904 |
---|---|
author | Schwarzkopf, Ran Meftah, Morteza Marwin, Scott E. Zabat, Michelle A. Muir, Jeffrey M. Lamb, Iain R. |
author_facet | Schwarzkopf, Ran Meftah, Morteza Marwin, Scott E. Zabat, Michelle A. Muir, Jeffrey M. Lamb, Iain R. |
author_sort | Schwarzkopf, Ran |
collection | PubMed |
description | PURPOSE: Navigated total knee arthroplasty (TKA) improves implant alignment by providing feedback on resection parameters based on femoral and tibial cutting guide positions. However, saw blade thickness, deflection, and cutting guide motion may lead to final bone cuts differing from planned resections, potentially contributing to suboptimal component alignment. We used an imageless navigation device to intraoperatively quantify the magnitude of error between planned and actual resections, hypothesizing final bone cuts will differ from planned alignment. MATERIALS AND METHODS: A retrospective study including 60 consecutive patients undergoing primary TKA using a novel imageless navigation device was conducted. Device measurements of resection parameters were obtained via attachment of optical trackers to femoral and tibial cutting guides prior to resection. Following resection, optical trackers were placed directly on the bone cut surface and measurements were recorded. Cutting guide and bone resection measurements of both femoral and tibial varus/valgus, femoral flexion, tibial slope angles, and both femoral and tibial medial and lateral resection depths were compared using a Student's t-test. RESULTS: Femoral cutting guide position differed from the actual cut by an average 0.6 ± 0.5° (p = 0.85) in the varus/valgus angle and 1.0 ± 1.0° (p = 0.003) in the flexion/extension angle. The difference between planned and actual cut measurements for medial and lateral femoral resection depth was 1.1 ± 1.1 mm (p = 0.32) and 1.2 ± 1.0 mm (p = 0.067), respectively. Planned cut measurements based on tibial guide position differed from the actual cut by an average of 0.9 ± 0.8° (p = 0.63) in the varus/valgus angle and 1.1 ± 1.0° (p = 0.95) in slope angle. Measurement of medial and lateral tibial resection depth differed by an average of 0.1 ± 1.8 mm (p = 0.78) and 0.2 ± 2.1 mm (p = 0.85), respectively. CONCLUSIONS: Significant discrepancies between planned and actual femoral bone resection were demonstrated for flexion/extension angle, likely the result of cutting error. Our data highlights the importance of cut verification postresection to confirm planned resections are achieved, and suggests imageless navigation may be a source of feedback that would allow surgeons to intraoperatively adjust resections to achieve optimal implant alignment. |
format | Online Article Text |
id | pubmed-8645113 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-86451132021-12-13 The use of imageless navigation to quantify cutting error in total knee arthroplasty Schwarzkopf, Ran Meftah, Morteza Marwin, Scott E. Zabat, Michelle A. Muir, Jeffrey M. Lamb, Iain R. Knee Surg Relat Res Research Article PURPOSE: Navigated total knee arthroplasty (TKA) improves implant alignment by providing feedback on resection parameters based on femoral and tibial cutting guide positions. However, saw blade thickness, deflection, and cutting guide motion may lead to final bone cuts differing from planned resections, potentially contributing to suboptimal component alignment. We used an imageless navigation device to intraoperatively quantify the magnitude of error between planned and actual resections, hypothesizing final bone cuts will differ from planned alignment. MATERIALS AND METHODS: A retrospective study including 60 consecutive patients undergoing primary TKA using a novel imageless navigation device was conducted. Device measurements of resection parameters were obtained via attachment of optical trackers to femoral and tibial cutting guides prior to resection. Following resection, optical trackers were placed directly on the bone cut surface and measurements were recorded. Cutting guide and bone resection measurements of both femoral and tibial varus/valgus, femoral flexion, tibial slope angles, and both femoral and tibial medial and lateral resection depths were compared using a Student's t-test. RESULTS: Femoral cutting guide position differed from the actual cut by an average 0.6 ± 0.5° (p = 0.85) in the varus/valgus angle and 1.0 ± 1.0° (p = 0.003) in the flexion/extension angle. The difference between planned and actual cut measurements for medial and lateral femoral resection depth was 1.1 ± 1.1 mm (p = 0.32) and 1.2 ± 1.0 mm (p = 0.067), respectively. Planned cut measurements based on tibial guide position differed from the actual cut by an average of 0.9 ± 0.8° (p = 0.63) in the varus/valgus angle and 1.1 ± 1.0° (p = 0.95) in slope angle. Measurement of medial and lateral tibial resection depth differed by an average of 0.1 ± 1.8 mm (p = 0.78) and 0.2 ± 2.1 mm (p = 0.85), respectively. CONCLUSIONS: Significant discrepancies between planned and actual femoral bone resection were demonstrated for flexion/extension angle, likely the result of cutting error. Our data highlights the importance of cut verification postresection to confirm planned resections are achieved, and suggests imageless navigation may be a source of feedback that would allow surgeons to intraoperatively adjust resections to achieve optimal implant alignment. BioMed Central 2021-12-04 /pmc/articles/PMC8645113/ /pubmed/34863317 http://dx.doi.org/10.1186/s43019-021-00125-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Schwarzkopf, Ran Meftah, Morteza Marwin, Scott E. Zabat, Michelle A. Muir, Jeffrey M. Lamb, Iain R. The use of imageless navigation to quantify cutting error in total knee arthroplasty |
title | The use of imageless navigation to quantify cutting error in total knee arthroplasty |
title_full | The use of imageless navigation to quantify cutting error in total knee arthroplasty |
title_fullStr | The use of imageless navigation to quantify cutting error in total knee arthroplasty |
title_full_unstemmed | The use of imageless navigation to quantify cutting error in total knee arthroplasty |
title_short | The use of imageless navigation to quantify cutting error in total knee arthroplasty |
title_sort | use of imageless navigation to quantify cutting error in total knee arthroplasty |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8645113/ https://www.ncbi.nlm.nih.gov/pubmed/34863317 http://dx.doi.org/10.1186/s43019-021-00125-z |
work_keys_str_mv | AT schwarzkopfran theuseofimagelessnavigationtoquantifycuttingerrorintotalkneearthroplasty AT meftahmorteza theuseofimagelessnavigationtoquantifycuttingerrorintotalkneearthroplasty AT marwinscotte theuseofimagelessnavigationtoquantifycuttingerrorintotalkneearthroplasty AT zabatmichellea theuseofimagelessnavigationtoquantifycuttingerrorintotalkneearthroplasty AT muirjeffreym theuseofimagelessnavigationtoquantifycuttingerrorintotalkneearthroplasty AT lambiainr theuseofimagelessnavigationtoquantifycuttingerrorintotalkneearthroplasty AT schwarzkopfran useofimagelessnavigationtoquantifycuttingerrorintotalkneearthroplasty AT meftahmorteza useofimagelessnavigationtoquantifycuttingerrorintotalkneearthroplasty AT marwinscotte useofimagelessnavigationtoquantifycuttingerrorintotalkneearthroplasty AT zabatmichellea useofimagelessnavigationtoquantifycuttingerrorintotalkneearthroplasty AT muirjeffreym useofimagelessnavigationtoquantifycuttingerrorintotalkneearthroplasty AT lambiainr useofimagelessnavigationtoquantifycuttingerrorintotalkneearthroplasty |