Cargando…

Scan-rescan repeatability of axonal imaging metrics using high-gradient diffusion MRI and statistical implications for study design

Axon diameter mapping using diffusion MRI in the living human brain has attracted growing interests with the increasing availability of high gradient strength MRI systems. A systematic assessment of the consistency of axon diameter estimates within and between individuals is needed to gain a compreh...

Descripción completa

Detalles Bibliográficos
Autores principales: Fan, Qiuyun, Polackal, Maya N., Tian, Qiyuan, Ngamsombat, Chanon, Nummenmaa, Aapo, Witzel, Thomas, Klawiter, Eric C., Huang, Susie Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8646020/
https://www.ncbi.nlm.nih.gov/pubmed/34216774
http://dx.doi.org/10.1016/j.neuroimage.2021.118323
_version_ 1784610436075749376
author Fan, Qiuyun
Polackal, Maya N.
Tian, Qiyuan
Ngamsombat, Chanon
Nummenmaa, Aapo
Witzel, Thomas
Klawiter, Eric C.
Huang, Susie Y.
author_facet Fan, Qiuyun
Polackal, Maya N.
Tian, Qiyuan
Ngamsombat, Chanon
Nummenmaa, Aapo
Witzel, Thomas
Klawiter, Eric C.
Huang, Susie Y.
author_sort Fan, Qiuyun
collection PubMed
description Axon diameter mapping using diffusion MRI in the living human brain has attracted growing interests with the increasing availability of high gradient strength MRI systems. A systematic assessment of the consistency of axon diameter estimates within and between individuals is needed to gain a comprehensive understanding of how such methods extend to quantifying differences in axon diameter index between groups and facilitate the design of neurobiological studies using such measures. We examined the scan-rescan repeatability of axon diameter index estimation based on the spherical mean technique (SMT) approach using diffusion MRI data acquired with gradient strengths up to 300 mT/m on a 3T Connectom system in 7 healthy volunteers. We performed statistical power analyses using data acquired with the same protocol in a larger cohort consisting of 15 healthy adults to investigate the implications for study design. Results revealed a high degree of repeatability in voxel-wise restricted volume fraction estimates and tract-wise estimates of axon diameter index derived from high-gradient diffusion MRI data. On the region of interest (ROI) level, across white matter tracts in the whole brain, the Pearson’s correlation coefficient of the axon diameter index estimated between scan and rescan experiments was r = 0.72 with an absolute deviation of 0.18 μm. For an anticipated 10% effect size in studies of axon diameter index, most white matter regions required a sample size of less than 15 people to observe a measurable difference between groups using an ROI-based approach. To facilitate the use of high-gradient strength diffusion MRI data for neuroscientific studies of axonal microstructure, the comprehensive multi-gradient strength, multi-diffusion time data used in this work will be made publicly available, in support of open science and increasing the accessibility of such data to the greater scientific community.
format Online
Article
Text
id pubmed-8646020
institution National Center for Biotechnology Information
language English
publishDate 2021
record_format MEDLINE/PubMed
spelling pubmed-86460202021-12-06 Scan-rescan repeatability of axonal imaging metrics using high-gradient diffusion MRI and statistical implications for study design Fan, Qiuyun Polackal, Maya N. Tian, Qiyuan Ngamsombat, Chanon Nummenmaa, Aapo Witzel, Thomas Klawiter, Eric C. Huang, Susie Y. Neuroimage Article Axon diameter mapping using diffusion MRI in the living human brain has attracted growing interests with the increasing availability of high gradient strength MRI systems. A systematic assessment of the consistency of axon diameter estimates within and between individuals is needed to gain a comprehensive understanding of how such methods extend to quantifying differences in axon diameter index between groups and facilitate the design of neurobiological studies using such measures. We examined the scan-rescan repeatability of axon diameter index estimation based on the spherical mean technique (SMT) approach using diffusion MRI data acquired with gradient strengths up to 300 mT/m on a 3T Connectom system in 7 healthy volunteers. We performed statistical power analyses using data acquired with the same protocol in a larger cohort consisting of 15 healthy adults to investigate the implications for study design. Results revealed a high degree of repeatability in voxel-wise restricted volume fraction estimates and tract-wise estimates of axon diameter index derived from high-gradient diffusion MRI data. On the region of interest (ROI) level, across white matter tracts in the whole brain, the Pearson’s correlation coefficient of the axon diameter index estimated between scan and rescan experiments was r = 0.72 with an absolute deviation of 0.18 μm. For an anticipated 10% effect size in studies of axon diameter index, most white matter regions required a sample size of less than 15 people to observe a measurable difference between groups using an ROI-based approach. To facilitate the use of high-gradient strength diffusion MRI data for neuroscientific studies of axonal microstructure, the comprehensive multi-gradient strength, multi-diffusion time data used in this work will be made publicly available, in support of open science and increasing the accessibility of such data to the greater scientific community. 2021-07-01 2021-10-15 /pmc/articles/PMC8646020/ /pubmed/34216774 http://dx.doi.org/10.1016/j.neuroimage.2021.118323 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license
spellingShingle Article
Fan, Qiuyun
Polackal, Maya N.
Tian, Qiyuan
Ngamsombat, Chanon
Nummenmaa, Aapo
Witzel, Thomas
Klawiter, Eric C.
Huang, Susie Y.
Scan-rescan repeatability of axonal imaging metrics using high-gradient diffusion MRI and statistical implications for study design
title Scan-rescan repeatability of axonal imaging metrics using high-gradient diffusion MRI and statistical implications for study design
title_full Scan-rescan repeatability of axonal imaging metrics using high-gradient diffusion MRI and statistical implications for study design
title_fullStr Scan-rescan repeatability of axonal imaging metrics using high-gradient diffusion MRI and statistical implications for study design
title_full_unstemmed Scan-rescan repeatability of axonal imaging metrics using high-gradient diffusion MRI and statistical implications for study design
title_short Scan-rescan repeatability of axonal imaging metrics using high-gradient diffusion MRI and statistical implications for study design
title_sort scan-rescan repeatability of axonal imaging metrics using high-gradient diffusion mri and statistical implications for study design
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8646020/
https://www.ncbi.nlm.nih.gov/pubmed/34216774
http://dx.doi.org/10.1016/j.neuroimage.2021.118323
work_keys_str_mv AT fanqiuyun scanrescanrepeatabilityofaxonalimagingmetricsusinghighgradientdiffusionmriandstatisticalimplicationsforstudydesign
AT polackalmayan scanrescanrepeatabilityofaxonalimagingmetricsusinghighgradientdiffusionmriandstatisticalimplicationsforstudydesign
AT tianqiyuan scanrescanrepeatabilityofaxonalimagingmetricsusinghighgradientdiffusionmriandstatisticalimplicationsforstudydesign
AT ngamsombatchanon scanrescanrepeatabilityofaxonalimagingmetricsusinghighgradientdiffusionmriandstatisticalimplicationsforstudydesign
AT nummenmaaaapo scanrescanrepeatabilityofaxonalimagingmetricsusinghighgradientdiffusionmriandstatisticalimplicationsforstudydesign
AT witzelthomas scanrescanrepeatabilityofaxonalimagingmetricsusinghighgradientdiffusionmriandstatisticalimplicationsforstudydesign
AT klawiterericc scanrescanrepeatabilityofaxonalimagingmetricsusinghighgradientdiffusionmriandstatisticalimplicationsforstudydesign
AT huangsusiey scanrescanrepeatabilityofaxonalimagingmetricsusinghighgradientdiffusionmriandstatisticalimplicationsforstudydesign