In-line Pullout Strength of 2 Acetabular Fixation Methods for Ligamentum Teres Reconstruction of the Hip: A Cadaveric Study
BACKGROUND: Ligamentum teres (LT) reconstruction is an appropriate alternative in select cases of LT full-thickness tears, resulting in hip micro- or macroinstability. Graft fixation at the acetabular fossa is critical to achieving the best functional results. PURPOSE: The purpose of this study is t...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8646775/ https://www.ncbi.nlm.nih.gov/pubmed/34881346 http://dx.doi.org/10.1177/23259671211052533 |
_version_ | 1784610509687881728 |
---|---|
author | Lall, Ajay C. Ankem, Hari K. Ryan, Michael K. Beason, David P. Diulus, Samantha C. Roach, Ryan P. Rosinsky, Philip J. Maldonado, David R. Emblom, Benton A. Domb, Benjamin G. |
author_facet | Lall, Ajay C. Ankem, Hari K. Ryan, Michael K. Beason, David P. Diulus, Samantha C. Roach, Ryan P. Rosinsky, Philip J. Maldonado, David R. Emblom, Benton A. Domb, Benjamin G. |
author_sort | Lall, Ajay C. |
collection | PubMed |
description | BACKGROUND: Ligamentum teres (LT) reconstruction is an appropriate alternative in select cases of LT full-thickness tears, resulting in hip micro- or macroinstability. Graft fixation at the acetabular fossa is critical to achieving the best functional results. PURPOSE: The purpose of this study is to compare the pullout strength of 2 graft fixation methods used for LT reconstruction of the hip. STUDY DESIGN: Controlled laboratory study. METHODS: In 7 cadaveric specimens, the acetabular socket was prepared after the native LT was transected and the femoral head was removed. Seven separate tibialis anterior grafts were then prepared by suturing a running-locking No. 2 suture on each tail of the graft. Three specimens had fixation of the graft to the acetabulum using an adjustable cortical suspension suture button; the remaining 4 were fixed to the acetabulum using a knotless suture anchor. Specimens were then mounted onto a custom jig within a mechanical test frame to allow for the in-line pull of the graft fixation construct. After a preload of 5 N, each specimen was loaded to failure at 0.5 mm/s. Stiffness and load to failure were measured for each specimen construct. RESULTS: Suture button fixation had a higher mean load to failure when compared with the knotless anchor fixation method (mean ± SD, 438.1 ± 114.3 vs 195.9 ± 50.0 N; P = .01). There was no significant difference in mean stiffness between the methods of fixation (24.5 ± 1.4 vs 26.5 ± 5.8 N/mm; P = .6). CONCLUSION: In this cadaveric study, the suture button fixation demonstrated greater load to failure than the knotless anchor fixation. CLINICAL RELEVANCE: Results of this study can guide surgical decision making when selecting an acetabular fixation method for LT reconstruction. |
format | Online Article Text |
id | pubmed-8646775 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-86467752021-12-07 In-line Pullout Strength of 2 Acetabular Fixation Methods for Ligamentum Teres Reconstruction of the Hip: A Cadaveric Study Lall, Ajay C. Ankem, Hari K. Ryan, Michael K. Beason, David P. Diulus, Samantha C. Roach, Ryan P. Rosinsky, Philip J. Maldonado, David R. Emblom, Benton A. Domb, Benjamin G. Orthop J Sports Med Article BACKGROUND: Ligamentum teres (LT) reconstruction is an appropriate alternative in select cases of LT full-thickness tears, resulting in hip micro- or macroinstability. Graft fixation at the acetabular fossa is critical to achieving the best functional results. PURPOSE: The purpose of this study is to compare the pullout strength of 2 graft fixation methods used for LT reconstruction of the hip. STUDY DESIGN: Controlled laboratory study. METHODS: In 7 cadaveric specimens, the acetabular socket was prepared after the native LT was transected and the femoral head was removed. Seven separate tibialis anterior grafts were then prepared by suturing a running-locking No. 2 suture on each tail of the graft. Three specimens had fixation of the graft to the acetabulum using an adjustable cortical suspension suture button; the remaining 4 were fixed to the acetabulum using a knotless suture anchor. Specimens were then mounted onto a custom jig within a mechanical test frame to allow for the in-line pull of the graft fixation construct. After a preload of 5 N, each specimen was loaded to failure at 0.5 mm/s. Stiffness and load to failure were measured for each specimen construct. RESULTS: Suture button fixation had a higher mean load to failure when compared with the knotless anchor fixation method (mean ± SD, 438.1 ± 114.3 vs 195.9 ± 50.0 N; P = .01). There was no significant difference in mean stiffness between the methods of fixation (24.5 ± 1.4 vs 26.5 ± 5.8 N/mm; P = .6). CONCLUSION: In this cadaveric study, the suture button fixation demonstrated greater load to failure than the knotless anchor fixation. CLINICAL RELEVANCE: Results of this study can guide surgical decision making when selecting an acetabular fixation method for LT reconstruction. SAGE Publications 2021-12-02 /pmc/articles/PMC8646775/ /pubmed/34881346 http://dx.doi.org/10.1177/23259671211052533 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Article Lall, Ajay C. Ankem, Hari K. Ryan, Michael K. Beason, David P. Diulus, Samantha C. Roach, Ryan P. Rosinsky, Philip J. Maldonado, David R. Emblom, Benton A. Domb, Benjamin G. In-line Pullout Strength of 2 Acetabular Fixation Methods for Ligamentum Teres Reconstruction of the Hip: A Cadaveric Study |
title | In-line Pullout Strength of 2 Acetabular Fixation Methods for Ligamentum Teres Reconstruction of the Hip: A Cadaveric Study |
title_full | In-line Pullout Strength of 2 Acetabular Fixation Methods for Ligamentum Teres Reconstruction of the Hip: A Cadaveric Study |
title_fullStr | In-line Pullout Strength of 2 Acetabular Fixation Methods for Ligamentum Teres Reconstruction of the Hip: A Cadaveric Study |
title_full_unstemmed | In-line Pullout Strength of 2 Acetabular Fixation Methods for Ligamentum Teres Reconstruction of the Hip: A Cadaveric Study |
title_short | In-line Pullout Strength of 2 Acetabular Fixation Methods for Ligamentum Teres Reconstruction of the Hip: A Cadaveric Study |
title_sort | in-line pullout strength of 2 acetabular fixation methods for ligamentum teres reconstruction of the hip: a cadaveric study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8646775/ https://www.ncbi.nlm.nih.gov/pubmed/34881346 http://dx.doi.org/10.1177/23259671211052533 |
work_keys_str_mv | AT lallajayc inlinepulloutstrengthof2acetabularfixationmethodsforligamentumteresreconstructionofthehipacadavericstudy AT ankemharik inlinepulloutstrengthof2acetabularfixationmethodsforligamentumteresreconstructionofthehipacadavericstudy AT ryanmichaelk inlinepulloutstrengthof2acetabularfixationmethodsforligamentumteresreconstructionofthehipacadavericstudy AT beasondavidp inlinepulloutstrengthof2acetabularfixationmethodsforligamentumteresreconstructionofthehipacadavericstudy AT diulussamanthac inlinepulloutstrengthof2acetabularfixationmethodsforligamentumteresreconstructionofthehipacadavericstudy AT roachryanp inlinepulloutstrengthof2acetabularfixationmethodsforligamentumteresreconstructionofthehipacadavericstudy AT rosinskyphilipj inlinepulloutstrengthof2acetabularfixationmethodsforligamentumteresreconstructionofthehipacadavericstudy AT maldonadodavidr inlinepulloutstrengthof2acetabularfixationmethodsforligamentumteresreconstructionofthehipacadavericstudy AT emblombentona inlinepulloutstrengthof2acetabularfixationmethodsforligamentumteresreconstructionofthehipacadavericstudy AT dombbenjaming inlinepulloutstrengthof2acetabularfixationmethodsforligamentumteresreconstructionofthehipacadavericstudy |